Simultaneous quantification of PCr, Cr, and pH in muscle CEST-MRI

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic Resonance in Medicine Pub Date : 2025-03-31 DOI:10.1002/mrm.30508
Yi Wang, Caiwen Yan, Xinhong Feng, Nan Gao, Jia-Hong Gao, Xiaolei Song
{"title":"Simultaneous quantification of PCr, Cr, and pH in muscle CEST-MRI","authors":"Yi Wang,&nbsp;Caiwen Yan,&nbsp;Xinhong Feng,&nbsp;Nan Gao,&nbsp;Jia-Hong Gao,&nbsp;Xiaolei Song","doi":"10.1002/mrm.30508","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>CEST-MRI allows sensitive in vivo detection of PCr and Cr in muscle. However, the accurate quantification is difficult due to overlapped “peaks” from multiple solutes and mixed contributions from fractional concentration (<span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>f</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {f}_{\\mathrm{b}} $$</annotation>\n </semantics></math>) and exchange rate (<span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math>). This study aims to achieve simultaneous and accurate mapping of PCr, Cr, and pH in muscle.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A two-step quantification method was proposed, by considering the co-existence of PCr and Cr in muscle and their dynamic transition. Firstly, exchangeable protons resonating at +2.6 ppm (<span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>PCr</mi>\n <mn>2.6</mn>\n </msub>\n </mrow>\n <annotation>$$ {\\mathrm{PCr}}_{2.6} $$</annotation>\n </semantics></math>) were quantified using our previous gQUCESOP. In the second gQUCESOP for resolving parameters at +1.9 ppm, we included both Cr's and another exchangeable guanidino proton of PCr resonating at +1.9 ppm (<span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>PCr</mi>\n <mn>1.9</mn>\n </msub>\n </mrow>\n <annotation>$$ {\\mathrm{PCr}}_{1.9} $$</annotation>\n </semantics></math>), with <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>f</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {f}_{\\mathrm{b}} $$</annotation>\n </semantics></math> and <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math> for <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>PCr</mi>\n <mn>1.9</mn>\n </msub>\n </mrow>\n <annotation>$$ {\\mathrm{PCr}}_{1.9} $$</annotation>\n </semantics></math> estimated from <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>PCr</mi>\n <mn>2.6</mn>\n </msub>\n </mrow>\n <annotation>$$ {\\mathrm{PCr}}_{2.6} $$</annotation>\n </semantics></math> estimation in the first step. The method was validated by simulation and phantom study. In vivo rat experiments were performed at 9.4T, with pH measured also by <sup>31</sup>P-MRS.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Simulation suggested an over-estimated <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>f</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {f}_{\\mathrm{b}} $$</annotation>\n </semantics></math> and an under-estimated <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math> of Cr if including a non-neglectable content of PCr. For a phantom with mixed PCr and Cr, the proposed method allowed accurate calculation of both concentrations and pH. For in vivo rat scans performed before and right after euthanasia, our methods achieved coincided <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>f</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {f}_{\\mathrm{b}} $$</annotation>\n </semantics></math> and <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math> with literatures. Furthermore, the pH values from <sup>31</sup>P-MRS, <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math> of <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>PCr</mi>\n <mn>2.6</mn>\n </msub>\n </mrow>\n <annotation>$$ {\\mathrm{PCr}}_{2.6} $$</annotation>\n </semantics></math>, and <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math> of Cr could verify each other.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The proposed method is promising for quantifying the <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>f</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {f}_{\\mathrm{b}} $$</annotation>\n </semantics></math> and <span></span><math>\n <semantics>\n <mrow>\n <msub>\n <mi>k</mi>\n <mi>b</mi>\n </msub>\n </mrow>\n <annotation>$$ {k}_{\\mathrm{b}} $$</annotation>\n </semantics></math> for both PCr and Cr in skeletal muscular tissue.</p>\n </section>\n </div>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":"94 2","pages":"640-650"},"PeriodicalIF":3.0000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mrm.30508","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

CEST-MRI allows sensitive in vivo detection of PCr and Cr in muscle. However, the accurate quantification is difficult due to overlapped “peaks” from multiple solutes and mixed contributions from fractional concentration ( f b $$ {f}_{\mathrm{b}} $$ ) and exchange rate ( k b $$ {k}_{\mathrm{b}} $$ ). This study aims to achieve simultaneous and accurate mapping of PCr, Cr, and pH in muscle.

Methods

A two-step quantification method was proposed, by considering the co-existence of PCr and Cr in muscle and their dynamic transition. Firstly, exchangeable protons resonating at +2.6 ppm ( PCr 2.6 $$ {\mathrm{PCr}}_{2.6} $$ ) were quantified using our previous gQUCESOP. In the second gQUCESOP for resolving parameters at +1.9 ppm, we included both Cr's and another exchangeable guanidino proton of PCr resonating at +1.9 ppm ( PCr 1.9 $$ {\mathrm{PCr}}_{1.9} $$ ), with f b $$ {f}_{\mathrm{b}} $$ and k b $$ {k}_{\mathrm{b}} $$ for PCr 1.9 $$ {\mathrm{PCr}}_{1.9} $$ estimated from PCr 2.6 $$ {\mathrm{PCr}}_{2.6} $$ estimation in the first step. The method was validated by simulation and phantom study. In vivo rat experiments were performed at 9.4T, with pH measured also by 31P-MRS.

Results

Simulation suggested an over-estimated f b $$ {f}_{\mathrm{b}} $$ and an under-estimated k b $$ {k}_{\mathrm{b}} $$ of Cr if including a non-neglectable content of PCr. For a phantom with mixed PCr and Cr, the proposed method allowed accurate calculation of both concentrations and pH. For in vivo rat scans performed before and right after euthanasia, our methods achieved coincided f b $$ {f}_{\mathrm{b}} $$ and k b $$ {k}_{\mathrm{b}} $$ with literatures. Furthermore, the pH values from 31P-MRS, k b $$ {k}_{\mathrm{b}} $$ of PCr 2.6 $$ {\mathrm{PCr}}_{2.6} $$ , and k b $$ {k}_{\mathrm{b}} $$ of Cr could verify each other.

Conclusion

The proposed method is promising for quantifying the f b $$ {f}_{\mathrm{b}} $$ and k b $$ {k}_{\mathrm{b}} $$ for both PCr and Cr in skeletal muscular tissue.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肌肉 CEST-MRI 中 PCr、Cr 和 pH 的同步量化。
目的:CEST-MRI可以在体内灵敏地检测肌肉中的PCr和Cr。然而,由于多个溶质重叠的“峰”和分数浓度(f b $$ {f}_{\mathrm{b}} $$)和交换率(k b $$ {k}_{\mathrm{b}} $$)的混合贡献,精确的定量是困难的。本研究旨在实现肌肉中PCr、Cr和pH的同步准确定位。方法:考虑肌肉中PCr和Cr的共存及其动态转变,提出两步定量方法。首先,使用我们之前的gQUCESOP对+2.6 ppm (PCr 2.6 $$ {\mathrm{PCr}}_{2.6} $$)共振的交换质子进行定量。在第二个求解+1.9 ppm参数的gQUCESOP中,我们纳入了Cr's和另一个在+1.9 ppm (PCr 1.9 $$ {\mathrm{PCr}}_{1.9} $$)共振的可交换胍基嘌呤质子,其中PCr 1.9 $$ {\mathrm{PCr}}_{1.9} $$的f b $$ {f}_{\mathrm{b}} $$和k b $$ {k}_{\mathrm{b}} $$是根据第一步PCr 2.6 $$ {\mathrm{PCr}}_{2.6} $$的估计估计的。仿真和仿真实验验证了该方法的有效性。在9.4T下进行大鼠体内实验,并采用31P-MRS测定pH值。结果:模拟表明,如果包含不可忽略的PCr含量,则Cr的f b $$ {f}_{\mathrm{b}} $$被高估,k b $$ {k}_{\mathrm{b}} $$被低估。对于混合PCr和Cr的幻体,所提出的方法可以准确计算浓度和ph。对于安乐死前后进行的活体大鼠扫描,我们的方法得到的结果与文献相符f b $$ {f}_{\mathrm{b}} $$和k b $$ {k}_{\mathrm{b}} $$。此外,31P-MRS的pH值,PCr 2.6 $$ {\mathrm{PCr}}_{2.6} $$的k b $$ {k}_{\mathrm{b}} $$和Cr的k b $$ {k}_{\mathrm{b}} $$可以相互验证。结论:该方法可用于骨骼肌组织中PCr和Cr的f b $$ {f}_{\mathrm{b}} $$和k b $$ {k}_{\mathrm{b}} $$的定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
期刊最新文献
Longitudinal Awake Mouse fMRI During Voluntary Locomotion Using Zero TE Imaging and a Novel Treadmill Training Protocol. Strong-Gradient Diffusion-Weighted Imaging of Prostate Cancer Using an Inside-Out Nonlinear Gradient Coil. Early Detection of Neuroinflammation and White Matter Damage Following Dorsal Spinal Nerve Root Sectioning in a Nonhuman Primate Model. EM Simulation Model of a Clinically-Used RF Head Coil at 7 T. A Novel 9-Channel 1H, 3-Channel 31P Radiofrequency Coil for Interleaved Multinuclear Studies of Human Calf Muscle at 7 T.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1