2025 Japanese Heart Rhythm Society / Japanese Circulation Society Consensus Statement on the Appropriate Use of Ambulatory and Wearable Electrocardiographs.

IF 3.7 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Circulation Journal Pub Date : 2025-05-23 Epub Date: 2025-04-15 DOI:10.1253/circj.CJ-24-0960
Takanori Ikeda, Takashi Ashihara, Yu-Ki Iwasaki, Maki Ono, Nobuyuki Kagiyama, Takehiro Kimura, Kengo Kusano, Ritsuko Kohno, Keita Saku, Tetsuo Sasano, Keitaro Senoo, Seiji Takatsuki, Naohiko Takahashi, Mitsuru Takami, Yukiko Nakano, Kenichi Hashimoto, Katsuhito Fujiu, Tadashi Fujino, Atsushi Mizuno, Koichiro Yoshioka, Eiichi Watanabe, Wataru Shimizu, Koichi Node
{"title":"2025 Japanese Heart Rhythm Society / Japanese Circulation Society Consensus Statement on the Appropriate Use of Ambulatory and Wearable Electrocardiographs.","authors":"Takanori Ikeda, Takashi Ashihara, Yu-Ki Iwasaki, Maki Ono, Nobuyuki Kagiyama, Takehiro Kimura, Kengo Kusano, Ritsuko Kohno, Keita Saku, Tetsuo Sasano, Keitaro Senoo, Seiji Takatsuki, Naohiko Takahashi, Mitsuru Takami, Yukiko Nakano, Kenichi Hashimoto, Katsuhito Fujiu, Tadashi Fujino, Atsushi Mizuno, Koichiro Yoshioka, Eiichi Watanabe, Wataru Shimizu, Koichi Node","doi":"10.1253/circj.CJ-24-0960","DOIUrl":null,"url":null,"abstract":"<p><p>Recently, some clinicians have been diagnosing and treating arrhythmias on the basis of electrocardiogram (ECG) devices with low accuracy. In Europe and the US, several statements on the use of ECGs have already been published by related academic societies. In addition, with the relaxation of regulations on media advertising ambulatory/wearable ECG devices, the frequency of use of simple ECG devices by the general public will increase in the future. Therefore, this statement describes the functions and features of non-invasive ambulatory or wearable ECG devices that have been approved as medical devices in Japan (and that can record ECGs remotely), as well as points to note when using them; provides an overview of data storage and security for ambulatory/wearable ECG devices and implantable loop recorders (ILRs), as well as discussing differences between their use and the use of non-invasive ambulatory/wearable ECG devices; and provides classes of recommendation for the use of these devices and their evaluation for each arrhythmia type or condition. We describe lead-based ambulatory ECG devices (classical 24-h Holter ECG monitoring), handheld ECG devices, handheld-based ECG devices using a smartphone, wearable ECG devices (smartwatch and garment ECG devices), and patch ECG devices. In addition, we provide information on methods that are not based on the original ECG, such as photoplethysmography and oscillometric blood pressure measurement, and describe the limitations of their use. We hope that the publication of this statement will lead to the appropriate use of ambulatory/wearable ECG devices in Japan.</p>","PeriodicalId":50691,"journal":{"name":"Circulation Journal","volume":" ","pages":"850-876"},"PeriodicalIF":3.7000,"publicationDate":"2025-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1253/circj.CJ-24-0960","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Recently, some clinicians have been diagnosing and treating arrhythmias on the basis of electrocardiogram (ECG) devices with low accuracy. In Europe and the US, several statements on the use of ECGs have already been published by related academic societies. In addition, with the relaxation of regulations on media advertising ambulatory/wearable ECG devices, the frequency of use of simple ECG devices by the general public will increase in the future. Therefore, this statement describes the functions and features of non-invasive ambulatory or wearable ECG devices that have been approved as medical devices in Japan (and that can record ECGs remotely), as well as points to note when using them; provides an overview of data storage and security for ambulatory/wearable ECG devices and implantable loop recorders (ILRs), as well as discussing differences between their use and the use of non-invasive ambulatory/wearable ECG devices; and provides classes of recommendation for the use of these devices and their evaluation for each arrhythmia type or condition. We describe lead-based ambulatory ECG devices (classical 24-h Holter ECG monitoring), handheld ECG devices, handheld-based ECG devices using a smartphone, wearable ECG devices (smartwatch and garment ECG devices), and patch ECG devices. In addition, we provide information on methods that are not based on the original ECG, such as photoplethysmography and oscillometric blood pressure measurement, and describe the limitations of their use. We hope that the publication of this statement will lead to the appropriate use of ambulatory/wearable ECG devices in Japan.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
2025日本心律学会/日本循环学会关于适当使用动态和可穿戴心电图仪的共识声明。
近年来,一些临床医生在诊断和治疗心律失常时一直依赖于心电图仪,但准确率较低。在欧洲和美国,相关的学术团体已经发表了一些关于使用心电图的声明。此外,随着对移动/可穿戴心电设备媒体广告监管的放宽,未来普通民众使用简易心电设备的频率将会增加。因此,本声明描述了在日本已被批准为医疗设备的无创动态或可穿戴ECG设备的功能和特点(可以远程记录ECG),以及使用时的注意事项;概述了动态/可穿戴ECG设备和植入式环路记录仪(ilr)的数据存储和安全性,并讨论了它们的使用与非侵入性动态/可穿戴ECG设备的使用之间的差异;并提供了使用这些设备的推荐类别以及对每种心律失常类型或状况的评估。我们描述了基于导联的动态ECG设备(经典的24小时动态心电图监测)、手持式ECG设备、使用智能手机的手持式ECG设备、可穿戴式ECG设备(智能手表和服装ECG设备)和贴片式ECG设备。此外,我们还提供了非基于原始心电图的方法的信息,如光电容积脉搏波和振荡血压测量,并描述了它们使用的局限性。我们希望本声明的发布将导致日本适当使用动态/可穿戴ECG设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Circulation Journal
Circulation Journal 医学-心血管系统
CiteScore
5.80
自引率
12.10%
发文量
471
审稿时长
1.6 months
期刊介绍: Circulation publishes original research manuscripts, review articles, and other content related to cardiovascular health and disease, including observational studies, clinical trials, epidemiology, health services and outcomes studies, and advances in basic and translational research.
期刊最新文献
Cardiac Conduction in Physiology and Disease - Gap Junction Biology, Immune Modulation, and Computational Electrophysiology. Resorcimoline Protects Against Myocardial Ischemia-Reperfusion Injury via Suppression of Oxidative Stress. Radiofrequency Ablation for Atrial Fibrillation in the Pulsed Field Era - Mechanisms, Principles, and Future Roles. Renal Denervation for Hypertension - Mechanisms, Evidence, and Clinical Integration. Maternal Folic Acid Supplementation Ameliorates Outflow Tract Malformations in Tbx1 Hypomorphic Mice via Notch and Midkine Signaling.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1