Adjustment Formula for Harmonizing Triglyceride Values in the Korea National Health and Nutrition Examination Survey, 2005-2022.

IF 3.9 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY Annals of Laboratory Medicine Pub Date : 2025-05-01 Epub Date: 2025-04-02 DOI:10.3343/alm.2024.0317
Rihwa Choi, Jong Do Seo, Eun-Jung Cho, Woochang Lee, Yeo-Min Yun
{"title":"Adjustment Formula for Harmonizing Triglyceride Values in the Korea National Health and Nutrition Examination Survey, 2005-2022.","authors":"Rihwa Choi, Jong Do Seo, Eun-Jung Cho, Woochang Lee, Yeo-Min Yun","doi":"10.3343/alm.2024.0317","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Korea National Health and Nutrition Examination Survey (KNHANES) triglyceride testing changed from the glycerol blanking method (2005-2021) to the glycerol nonblanking method (2022). We converted triglyceride data from 2005-2021 to that obtained since 2022 with different analytical methods.</p><p><strong>Methods: </strong>To develop a conversion equation, 98 fresh serum specimen pairs were compared using Passing-Bablok regression analysis. Implications of the conversion equation on epidemiological data were evaluated using KNHANES data from 2019-2021. Bias estimations determined using the Lipid Standardization Program (LSP) of the United States Centers for Disease Control and Prevention (CDC) enhanced the accuracy and comparability of the triglyceride results.</p><p><strong>Results: </strong>Triglyceride concentrations measured via the glycerol non-blanking method were 10.7 mg/dL (0.12 mmol/L, 10.0%) higher than those from the glycerol blanking method, with a 9.9 mg/dL (0.11 mmol/L, 5.0%) difference at a concentration of 200 mg/dL (2.26 mmol/L, N=98). The conversion equation <i>y</i> (glycerol non-blanking, 2022)=11.94+0.99<i>x</i> (glycerol blanking, 2005-2021) changed the mean triglyceride concentrations of the KNHANES 2019-2021 data (N=16,015) from 123.7 mg/dL (1.40 mmol/L, 95% confidence interval [CI]: 122.2-125.1 mg/dL [1.38-1.41 mmol/L]) to 134.3 mg/dL (1.52 mmol/L, 95% CI: 132.9-135.8 mg/dL [1.50-1.53 mmol/L]). Since 2022, bias monitoring using the CDC's LSP has remained within a 5.0% limit.</p><p><strong>Conclusions: </strong>KNHANES triglyceride values in 2022 (non-blanking) were substantially higher than those from 2005-2021 (blanking). Conversion equations helped effectively adjust 2005-2021 data. Researchers should consider adjusting the KNHANES triglyceride data based on their study characteristics.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":"291-299"},"PeriodicalIF":3.9000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11996691/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2024.0317","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Korea National Health and Nutrition Examination Survey (KNHANES) triglyceride testing changed from the glycerol blanking method (2005-2021) to the glycerol nonblanking method (2022). We converted triglyceride data from 2005-2021 to that obtained since 2022 with different analytical methods.

Methods: To develop a conversion equation, 98 fresh serum specimen pairs were compared using Passing-Bablok regression analysis. Implications of the conversion equation on epidemiological data were evaluated using KNHANES data from 2019-2021. Bias estimations determined using the Lipid Standardization Program (LSP) of the United States Centers for Disease Control and Prevention (CDC) enhanced the accuracy and comparability of the triglyceride results.

Results: Triglyceride concentrations measured via the glycerol non-blanking method were 10.7 mg/dL (0.12 mmol/L, 10.0%) higher than those from the glycerol blanking method, with a 9.9 mg/dL (0.11 mmol/L, 5.0%) difference at a concentration of 200 mg/dL (2.26 mmol/L, N=98). The conversion equation y (glycerol non-blanking, 2022)=11.94+0.99x (glycerol blanking, 2005-2021) changed the mean triglyceride concentrations of the KNHANES 2019-2021 data (N=16,015) from 123.7 mg/dL (1.40 mmol/L, 95% confidence interval [CI]: 122.2-125.1 mg/dL [1.38-1.41 mmol/L]) to 134.3 mg/dL (1.52 mmol/L, 95% CI: 132.9-135.8 mg/dL [1.50-1.53 mmol/L]). Since 2022, bias monitoring using the CDC's LSP has remained within a 5.0% limit.

Conclusions: KNHANES triglyceride values in 2022 (non-blanking) were substantially higher than those from 2005-2021 (blanking). Conversion equations helped effectively adjust 2005-2021 data. Researchers should consider adjusting the KNHANES triglyceride data based on their study characteristics.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
2005-2022年韩国国家健康和营养检查调查中甘油三酯值协调调整公式。
背景:韩国国民健康与营养检查调查(KNHANES)甘油三酯检测由甘油空白法(2005-2021)改为甘油非空白法(2022)。我们使用不同的分析方法将2005-2021年的甘油三酯数据转换为2022年以来的数据。方法:采用Passing-Bablok回归分析对98对新鲜血清标本进行比较,建立换算方程。使用2019-2021年的KNHANES数据评估转换方程对流行病学数据的影响。使用美国疾病控制和预防中心(CDC)的脂质标准化计划(LSP)确定的偏倚估计增强了甘油三酯结果的准确性和可比性。结果:甘油非空白法测得的甘油三酯浓度比甘油空白法测得的甘油三酯浓度高10.7 mg/dL (0.12 mmol/L, 10.0%),在浓度为200 mg/dL (2.26 mmol/L, N=98)时,差异为9.9 mg/dL (0.11 mmol/L, 5.0%)。转换方程y(甘油未空白,2022)=11.94+0.99x(甘油空白,2005-2021)将KNHANES 2019-2021数据(N=16,015)的平均甘油三酯浓度从123.7 mg/dL (1.40 mmol/L, 95%置信区间[CI]: 122.2-125.1 mg/dL [1.38-1.41 mmol/L])更改为134.3 mg/dL (1.52 mmol/L, 95% CI: 132.9-135.8 mg/dL [1.50-1.53 mmol/L])。自2022年以来,使用CDC LSP进行的偏差监测一直保持在5.0%的限制范围内。结论:2022年(非空白)的KNHANES甘油三酯值明显高于2005-2021年(空白)。转换方程有效地调整了2005-2021年的数据。研究人员应考虑根据他们的研究特点调整KNHANES甘油三酯数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Laboratory Medicine
Annals of Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
8.30
自引率
12.20%
发文量
100
审稿时长
6-12 weeks
期刊介绍: Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.
期刊最新文献
Natural Killer Cell Assays: Clinical Applications and Future Directions. Comparative Evaluation of the Effects of Serum Separator Tubes and Transport Systems on Hormone and Tumor Marker Measurements. Patient Data and refineR for Efficient Monitoring and Verifying Laboratory Reference Intervals: A Practical Approach. Diagnostic and Prognostic Utility of Monocyte Cell Population Data in Emergency Department Patients with Suspected Sepsis. Development and Evaluation of Artificial Intelligence-Based Two-Step Model for Automated Serum Quality Assessment in Clinical Laboratories.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1