Percutaneous pelvic ring fracture reduction using an external fixator: a technical trick and case series.

IF 2.6 3区 医学 Q2 ORTHOPEDICS International Orthopaedics Pub Date : 2025-07-01 Epub Date: 2025-04-02 DOI:10.1007/s00264-025-06509-0
Guillaume David, Nicholas J Tucker, Clement Marc, Vincent Steiger, Louis Rony, Cyril Mauffrey
{"title":"Percutaneous pelvic ring fracture reduction using an external fixator: a technical trick and case series.","authors":"Guillaume David, Nicholas J Tucker, Clement Marc, Vincent Steiger, Louis Rony, Cyril Mauffrey","doi":"10.1007/s00264-025-06509-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Pelvic ring and acetabular fractures pose significant morbidity and mortality risks due to substantial haemorrhage and internal organ injury. Many percutaneous reduction techniques involve manipulating the injured side while stabilizing the uninjured side, often requiring specific or costly equipment. This article presents a technique for creating a pelvic reduction frame using a standard external fixator.</p><p><strong>Method: </strong>We included surgical pelvic ring fractures between 2018 and 2022. Pelvic reduction was achieved using an external fixator (Hoffmann III, Stryker Corporation, Kalamazoo, Michigan, USA). Reduction quality was assessed according to the technique described by Lefaivre et al., based on the following criteria: mean asymmetry (mm), mean deformity index (mm), and mean maximum horizontal or vertical displacement (mm).</p><p><strong>Results: </strong>15 patients (10 men, 5 women, mean age 35 years) underwent surgical treatment for pelvic fractures using an external fixator and percutaneous fixation. Mean operative time was 130 min (range, 80-276). Postoperative imaging showed a mean maximum displacement of 5.4 mm and a mean asymmetry of 3.7 mm, with excellent or good reductions in 11 cases.</p><p><strong>Conclusion: </strong>This system uses widely available equipment and enables the benefits of percutaneous techniques, but surgical expertise remains the key to success.</p>","PeriodicalId":14450,"journal":{"name":"International Orthopaedics","volume":" ","pages":"1739-1746"},"PeriodicalIF":2.6000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178971/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-025-06509-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Pelvic ring and acetabular fractures pose significant morbidity and mortality risks due to substantial haemorrhage and internal organ injury. Many percutaneous reduction techniques involve manipulating the injured side while stabilizing the uninjured side, often requiring specific or costly equipment. This article presents a technique for creating a pelvic reduction frame using a standard external fixator.

Method: We included surgical pelvic ring fractures between 2018 and 2022. Pelvic reduction was achieved using an external fixator (Hoffmann III, Stryker Corporation, Kalamazoo, Michigan, USA). Reduction quality was assessed according to the technique described by Lefaivre et al., based on the following criteria: mean asymmetry (mm), mean deformity index (mm), and mean maximum horizontal or vertical displacement (mm).

Results: 15 patients (10 men, 5 women, mean age 35 years) underwent surgical treatment for pelvic fractures using an external fixator and percutaneous fixation. Mean operative time was 130 min (range, 80-276). Postoperative imaging showed a mean maximum displacement of 5.4 mm and a mean asymmetry of 3.7 mm, with excellent or good reductions in 11 cases.

Conclusion: This system uses widely available equipment and enables the benefits of percutaneous techniques, but surgical expertise remains the key to success.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用外固定架经皮骨盆环骨折复位:技术技巧和病例系列。
目的:骨盆环和髋臼骨折由于大量出血和内脏器官损伤,具有显著的发病率和死亡率风险。许多经皮复位技术涉及在稳定未受伤侧的同时操纵受伤侧,通常需要特殊或昂贵的设备。本文介绍了一种使用标准外固定架制作骨盆复位框架的技术。方法:我们纳入了2018年至2022年的手术盆腔环骨折。盆腔复位采用外固定架(Hoffmann III, Stryker Corporation, Kalamazoo, Michigan, USA)。根据Lefaivre等人描述的技术,根据以下标准评估复位质量:平均不对称(mm)、平均畸形指数(mm)和平均最大水平或垂直位移(mm)。结果:15例患者(男10例,女5例,平均年龄35岁)采用外固定架和经皮固定手术治疗骨盆骨折。平均手术时间130分钟(范围80-276)。术后影像学显示平均最大移位5.4 mm,平均不对称3.7 mm, 11例复位良好。结论:该系统使用了广泛可用的设备,并实现了经皮技术的优势,但手术专业知识仍然是成功的关键。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Orthopaedics
International Orthopaedics 医学-整形外科
CiteScore
5.50
自引率
7.40%
发文量
360
审稿时长
1 months
期刊介绍: International Orthopaedics, the Official Journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT) , publishes original papers from all over the world. The articles deal with clinical orthopaedic surgery or basic research directly connected with orthopaedic surgery. International Orthopaedics will also link all the members of SICOT by means of an insert that will be concerned with SICOT matters. Finally, it is expected that news and information regarding all aspects of orthopaedic surgery, including meetings, panels, instructional courses, etc. will be brought to the attention of the readers. Manuscripts submitted for publication must contain a statement to the effect that all human studies have been approved by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted. Reports of animal experiments must state that the "Principles of laboratory animal care" (NIH publication No. 85-23, revised 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable. The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfil the above-mentioned requirements.
期刊最新文献
Quality of life before and during the COVID-19 pandemic for people undergoing hip, knee and shoulder arthroplasty-nationwide results from the Australian Orthopaedic Association National Joint Replacement Registry. Autologous platelet-rich plasma versus hyaluronic acid, corticosteroids or saline for knee osteoarthritis: can blood draw volume serve as a proxy for platelet dose? A systematic review and meta-analysis. A new approach to the lower cervical-thoracic spine with dislocation of the sterno-clavicular joint: FAMA (Fast Anterior Medium Approach). Demographics and outcomes of unicondylar knee arthroplasty in Türkiye: a nationwide retrospective database study of eight thousand, five hundred and ninety cases. Capsular reconstruction versus excision in anterolateral total hip arthroplasty: a prospective randomized controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1