A multi-loop aptamer-based fluorescent aptasensor for enhanced detection of 17β-estradiol†

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2025-04-04 DOI:10.1039/D5AY00154D
Pakawat Kongpreecha, Arnon Buntha, Pattama Tongdee, Pinwen Peter Chiou and Sineenat Siri
{"title":"A multi-loop aptamer-based fluorescent aptasensor for enhanced detection of 17β-estradiol†","authors":"Pakawat Kongpreecha, Arnon Buntha, Pattama Tongdee, Pinwen Peter Chiou and Sineenat Siri","doi":"10.1039/D5AY00154D","DOIUrl":null,"url":null,"abstract":"<p >The modulation of 17β-estradiol (E2) level, even in trace amounts outside the normal range, plays a critical role in diagnosing and treating various diseases in females. This work presents a novel, simple, and highly sensitive method for E2 detection based on the designed repetitive-loop aptamer. The method is based on the different fluorescence intensities of SYBR Green I (SGI) to intercalate the DNA aptamer structures, which are changed upon interacting with E2. Among the designed aptamers containing 1–5 loop structures (designated as O1–O5), the O5-aptamer exhibited the highest E2 interaction and was employed to construct the O5-aptasensor. Under optimal conditions, the aptasensor displayed excellent sensitivity, with a linear detection range of 1–200 pM, a limit of detection (LOD) of 1.34 pM, and a limit of quantification (LOQ) of 4.48 pM. Its LOD is 13.5 folds lower than that of the L1-aptasensor. The O5-aptasensor specifically detected E2, distinguishing it from structurally similar compounds such as progesterone, genistein, diethylstilbestrol, bisphenol A, and chloramphenicol. Furthermore, the O5-aptasensor accurately detects E2 spiked in artificial urine and human serum samples, with recovery rates ranging from 98.73% to 109.00%, and relative standard deviations below 8%. The O5-aptasensor was tested on blood serum samples from seven hospital patients, and its performance was comparable to that of the hospital analysis for E2 measurement. These findings highlight the potential of the O5-aptasensor as a highly sensitive platform for clinical E2 detection, offering a viable alternative to existing methods.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 16","pages":" 3220-3228"},"PeriodicalIF":2.6000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d5ay00154d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The modulation of 17β-estradiol (E2) level, even in trace amounts outside the normal range, plays a critical role in diagnosing and treating various diseases in females. This work presents a novel, simple, and highly sensitive method for E2 detection based on the designed repetitive-loop aptamer. The method is based on the different fluorescence intensities of SYBR Green I (SGI) to intercalate the DNA aptamer structures, which are changed upon interacting with E2. Among the designed aptamers containing 1–5 loop structures (designated as O1–O5), the O5-aptamer exhibited the highest E2 interaction and was employed to construct the O5-aptasensor. Under optimal conditions, the aptasensor displayed excellent sensitivity, with a linear detection range of 1–200 pM, a limit of detection (LOD) of 1.34 pM, and a limit of quantification (LOQ) of 4.48 pM. Its LOD is 13.5 folds lower than that of the L1-aptasensor. The O5-aptasensor specifically detected E2, distinguishing it from structurally similar compounds such as progesterone, genistein, diethylstilbestrol, bisphenol A, and chloramphenicol. Furthermore, the O5-aptasensor accurately detects E2 spiked in artificial urine and human serum samples, with recovery rates ranging from 98.73% to 109.00%, and relative standard deviations below 8%. The O5-aptasensor was tested on blood serum samples from seven hospital patients, and its performance was comparable to that of the hospital analysis for E2 measurement. These findings highlight the potential of the O5-aptasensor as a highly sensitive platform for clinical E2 detection, offering a viable alternative to existing methods.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种基于多环配体的荧光配体传感器,用于增强检测17β-雌二醇。
17β-雌二醇(E2)水平的调节,即使是在正常范围之外的微量,在女性各种疾病的诊断和治疗中起着至关重要的作用。本文提出了一种新颖、简单、高灵敏度的E2检测方法,该方法基于所设计的重复环适体。该方法是基于SYBR Green I (SGI)的不同荧光强度插入DNA适体结构,这些结构在与E2相互作用时发生变化。在含有1-5个环结构的适体中,o5 -适体表现出最高的E2相互作用,并被用来构建o5 -适体传感器。在最佳条件下,该传感器具有良好的灵敏度,线性检测范围为1 ~ 200 pM,检出限为1.34 pM,定量限为4.48 pM。其LOD比l1 -适体传感器低13.5倍。o5 -适体传感器专门检测E2,将其与结构类似的化合物(如黄体酮、染料木素、己烯雌酚、双酚A和氯霉素)区分开来。此外,o5 - aptassensor能准确检测人工尿液和人血清中E2,回收率为98.73% ~ 109.00%,相对标准偏差小于8%。对7例医院患者的血清样本进行了o5 -适配体传感器测试,其性能与医院分析E2测量相当。这些发现突出了o5 -受体传感器作为临床E2检测的高灵敏度平台的潜力,为现有方法提供了可行的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
Electrochemical determination of dopamine using a flower-derived carbon quantum dots/polydopamine composite film modified electrode. Adhesive tape for spatially resolved and sensitive detection of lead in dust using XRF. Development and validation of MRM analysis of pesticide metabolites for the environmental safety assessment of biobeds disposal. A silica coated AgNCs fluorescence sensor for detection of cefixime in pharmaceutical products and biological samples. A dual-functional 8-hydroxyquinoline fluorescent probe for simultaneous detection of solvent microenvironments and trace water in organic media.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1