{"title":"Konar-MF ™: Versatile Utility Suggests Potential to Simplify Congenital Catheterization Laboratory Inventory.","authors":"Navaneetha Sasikumar, Pranoti Toshniwal, Usha Mandikal Kondakarna Sastry, Shweta Bakhru, Jayaranganath Mahimarangaiah, Nageshwara Rao Koneti, Raman Krishna Kumar","doi":"10.1007/s00246-025-03849-x","DOIUrl":null,"url":null,"abstract":"<p><p>KONAR-MF™ device is a novel, cone-shaped, medium profile, self-expanding, double-disk, nitinol occlusive device designed for the ventricular septal defect (VSD). Due to its unique design and easy deployment from either side and multiple occlusion layers, it has also been used to occlude defects other than VSD. A retrospective review was done from 2019 to 2024 from three institutions. All patients where the KONAR-MF™ device was used other than for VSD closure were included in this study. Standard post-procedure follow-up was at 1, 6, and 12 months for all patients. 79 off-label implantations of the KONAR-MF™ device were done for conditions that included 59 shunt lesions (patent ductus arteriosus -34, coronary arteriovenous fistula -12, pulmonary arteriovenous fistula -2, systemic arteriovenous fistula -3, aortopulmonary window -3, aortopulmonary collateral -5, Fontan fenestration closures -7, Fontan antegrade pulmonary valve closures -2, Abernethy malformations -3, decompressing vein -2, and paravalvular leak -2, others 4. The median fluoroscopy time was 10 min (IQR 6-18). The median duration of hospital stay was 2 days (IQR 1-4 days). There were no significant complications. Complete occlusion at the end of the procedure was documented in 72 (91.13%) patients. At a median follow-up of 18 months (IQR 12-28 months) in all except one patient who had mild residual flow with no device-/(procedure) related complications. The unique structure and compact profile of KONAR-MF™ enable a wide range of uses in catheter-based management of various CHDs with the potential to simplify the inventory of the catheterization laboratory.</p>","PeriodicalId":19814,"journal":{"name":"Pediatric Cardiology","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00246-025-03849-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
KONAR-MF™ device is a novel, cone-shaped, medium profile, self-expanding, double-disk, nitinol occlusive device designed for the ventricular septal defect (VSD). Due to its unique design and easy deployment from either side and multiple occlusion layers, it has also been used to occlude defects other than VSD. A retrospective review was done from 2019 to 2024 from three institutions. All patients where the KONAR-MF™ device was used other than for VSD closure were included in this study. Standard post-procedure follow-up was at 1, 6, and 12 months for all patients. 79 off-label implantations of the KONAR-MF™ device were done for conditions that included 59 shunt lesions (patent ductus arteriosus -34, coronary arteriovenous fistula -12, pulmonary arteriovenous fistula -2, systemic arteriovenous fistula -3, aortopulmonary window -3, aortopulmonary collateral -5, Fontan fenestration closures -7, Fontan antegrade pulmonary valve closures -2, Abernethy malformations -3, decompressing vein -2, and paravalvular leak -2, others 4. The median fluoroscopy time was 10 min (IQR 6-18). The median duration of hospital stay was 2 days (IQR 1-4 days). There were no significant complications. Complete occlusion at the end of the procedure was documented in 72 (91.13%) patients. At a median follow-up of 18 months (IQR 12-28 months) in all except one patient who had mild residual flow with no device-/(procedure) related complications. The unique structure and compact profile of KONAR-MF™ enable a wide range of uses in catheter-based management of various CHDs with the potential to simplify the inventory of the catheterization laboratory.
KONAR-MF™装置是一种新型的锥形、中等轮廓、自膨胀、双盘镍钛诺闭塞装置,专为室间隔缺损(VSD)设计。由于其独特的设计和易于从任何一侧和多个遮挡层部署,它也被用于遮挡VSD以外的缺陷。从2019年到2024年,对3个机构进行了回顾性审查。除室间隔关闭外,所有使用KONAR-MF™装置的患者均纳入本研究。所有患者的标准术后随访时间分别为1、6和12个月。79例经标签外植入的KONAR-MF™装置包括59例分流病变(动脉导管未闭-34例,冠状动脉动静脉瘘-12例,肺动静脉瘘-2例,全身动静脉瘘-3例,肺动脉窗-3例,肺动脉侧支-5例,Fontan开窗关闭-7例,Fontan顺行肺动脉瓣关闭-2例,Abernethy畸形-3例,减压静脉-2例,瓣旁漏-2例,其他4例)。中位透视时间为10 min (IQR 6-18)。中位住院时间为2天(IQR 1-4天)。无明显并发症。72例(91.13%)患者在手术结束时完全闭塞。中位随访时间为18个月(IQR为12-28个月),除1例患者有轻度残余血流且无器械/(手术)相关并发症外,其余患者均有。KONAR-MF™独特的结构和紧凑的外形使其在各种冠心病的导管管理中具有广泛的用途,并有可能简化导管实验室的库存。
期刊介绍:
The editor of Pediatric Cardiology welcomes original manuscripts concerning all aspects of heart disease in infants, children, and adolescents, including embryology and anatomy, physiology and pharmacology, biochemistry, pathology, genetics, radiology, clinical aspects, investigative cardiology, electrophysiology and echocardiography, and cardiac surgery. Articles which may include original articles, review articles, letters to the editor etc., must be written in English and must be submitted solely to Pediatric Cardiology.