Fabrication of cylindrical diffusion-facilitated organic electrochemical transistor and its sweat glucose sensing application

IF 2 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY International Journal of Mechanical and Materials Engineering Pub Date : 2025-04-09 DOI:10.1186/s40712-025-00267-y
Jamal Mohamed S., Sasi Karan Ramanujam Rajakumar, Murugasenapathi N. K., Tamilarasan Palanisamy
{"title":"Fabrication of cylindrical diffusion-facilitated organic electrochemical transistor and its sweat glucose sensing application","authors":"Jamal Mohamed S.,&nbsp;Sasi Karan Ramanujam Rajakumar,&nbsp;Murugasenapathi N. K.,&nbsp;Tamilarasan Palanisamy","doi":"10.1186/s40712-025-00267-y","DOIUrl":null,"url":null,"abstract":"<p>Organic electrochemical transistors (OECTs) have been widely tested used for biosensing applications due to high sensitivity, low operating potential, better signal-to-noise ratio and operation in aqueous medium. The electrochemical de-doping in OECTs is a diffusion-controlled process which crucially depends on the geometry of the channel. This report presents OECT with cylindrical channel and its application in detection of sweat glucose concentration. The cylindrical channel OECTs were fabricated by incorporating PEDOT:PSS-coated single cotton fibre as a channel. The cylindrical diffusion of ions into the channel is confirmed by the parallel combination of a resistor and Warburg impedance in electrochemical impedance spectroscopy. The non-linear current–voltage characteristics of the device closely follow Bernard<i>-</i>Malliaras model. The transconductance has been derived to be 2.48 × 10<sup>−4</sup> S from the transfer characteristics. The developed OECTs were deployed for glucose sensing by bioconjugating the gate terminal with glucose oxidase enzyme. A 1.4 mg/dL limit of detection, 2.8 mg/dL limit of quantification and 7.14-s average response time have been achieved with the device. As the device shows higher responsivity between 5 and 50 mg/dL, the OECT has been demonstrated as a wearable sweat glucose sensor.</p>","PeriodicalId":592,"journal":{"name":"International Journal of Mechanical and Materials Engineering","volume":"20 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://jmsg.springeropen.com/counter/pdf/10.1186/s40712-025-00267-y","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Mechanical and Materials Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40712-025-00267-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Organic electrochemical transistors (OECTs) have been widely tested used for biosensing applications due to high sensitivity, low operating potential, better signal-to-noise ratio and operation in aqueous medium. The electrochemical de-doping in OECTs is a diffusion-controlled process which crucially depends on the geometry of the channel. This report presents OECT with cylindrical channel and its application in detection of sweat glucose concentration. The cylindrical channel OECTs were fabricated by incorporating PEDOT:PSS-coated single cotton fibre as a channel. The cylindrical diffusion of ions into the channel is confirmed by the parallel combination of a resistor and Warburg impedance in electrochemical impedance spectroscopy. The non-linear current–voltage characteristics of the device closely follow Bernard-Malliaras model. The transconductance has been derived to be 2.48 × 10−4 S from the transfer characteristics. The developed OECTs were deployed for glucose sensing by bioconjugating the gate terminal with glucose oxidase enzyme. A 1.4 mg/dL limit of detection, 2.8 mg/dL limit of quantification and 7.14-s average response time have been achieved with the device. As the device shows higher responsivity between 5 and 50 mg/dL, the OECT has been demonstrated as a wearable sweat glucose sensor.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
圆柱形扩散型有机电化学晶体管的制备及其汗液葡萄糖传感应用
有机电化学晶体管(OECTs)具有灵敏度高、工作电位低、信噪比好、可在水介质中工作等优点,在生物传感领域得到了广泛的应用。OECTs中的电化学脱掺杂是一个扩散控制过程,其关键取决于通道的几何形状。本文介绍了带圆柱形通道的OECT及其在汗液葡萄糖浓度检测中的应用。采用PEDOT: pss涂层单棉纤维作为通道制备了圆柱形通道oect。在电化学阻抗谱中,电阻器和Warburg阻抗并联组合证实了离子在通道内的圆柱扩散。器件的非线性电流-电压特性与Bernard-Malliaras模型密切相关。从转移特性推导出跨导为2.48 × 10−4 S。开发的OECTs通过与葡萄糖氧化酶生物偶联的方式用于葡萄糖传感。该装置的检测限为1.4 mg/dL,定量限为2.8 mg/dL,平均响应时间为7.14 s。由于该设备在5至50 mg/dL之间显示出更高的响应性,OECT已被证明是一种可穿戴式汗液葡萄糖传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.60
自引率
0.00%
发文量
1
审稿时长
13 weeks
期刊最新文献
Advancing the reutilization of spent activated carbon for sculptural media: composites formulation and characterization Low-temperature plasma nitrocarburizing of 15 − 5 PH stainless steel for optimized surface hardness and corrosion resistance Synthesis and characterization of sulfanilic-acid mediated by ZnO/Graphene oxide composite with preliminary electrochemical assessment The influence of iodine donor forms on the characteristics of sedimentation-forming AgI-MСM48-MeIx hybrid powders Synthesis and comprehensive rheological investigation of gum acacia-grafted-poly(N,N-dimethylacrylamide) hydrogel incorporated with CoFe2O4 nanofillers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1