Machine learning prediction of effective radiation doses in various computed tomography applications: a virtual human phantom study.

Biomedizinische Technik. Biomedical engineering Pub Date : 2025-04-08 Print Date: 2025-08-26 DOI:10.1515/bmt-2024-0620
Handan Tanyildizi-Kokkulunk
{"title":"Machine learning prediction of effective radiation doses in various computed tomography applications: a virtual human phantom study.","authors":"Handan Tanyildizi-Kokkulunk","doi":"10.1515/bmt-2024-0620","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>In this work, it was aimed to employ machine learning (ML) algorithms to accurately forecast the radiation doses for phantoms while accounting for the most popular CT protocols.</p><p><strong>Methods: </strong>A cloud-based software was utilized to calculate the effective doses from different CT protocols. To simulate a range of adult patients with different weights, eight entire body mesh-based computational phantom sets were used. The head, neck, and chest-abdomen-pelvis CT scan characteristics were combined to create a dataset with 33 rows for each phantom and 792 rows total. At the ML stage, linear (LR), random forest (RF) and support vector regression (SVR) were used. Mean absolute error, mean squared error and accuracy were used to evaluate the performances.</p><p><strong>Results: </strong>The female phantoms received higher doses (7.8 %) than males. Furthermore, an average of 11 % more dose was taken to the normal weight phantom than to the overweight, the overweight in comparison to the obese I, and the obese I in comparison to the obese II. Among the ML algorithms, the LR showed 0 error rate and 100 % accuracy in predicting CT doses.</p><p><strong>Conclusions: </strong>The LR was shown to be the best approach out of those used in the ML estimation of CT-induced doses.</p>","PeriodicalId":93905,"journal":{"name":"Biomedizinische Technik. Biomedical engineering","volume":" ","pages":"385-391"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedizinische Technik. Biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/bmt-2024-0620","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/26 0:00:00","PubModel":"Print","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: In this work, it was aimed to employ machine learning (ML) algorithms to accurately forecast the radiation doses for phantoms while accounting for the most popular CT protocols.

Methods: A cloud-based software was utilized to calculate the effective doses from different CT protocols. To simulate a range of adult patients with different weights, eight entire body mesh-based computational phantom sets were used. The head, neck, and chest-abdomen-pelvis CT scan characteristics were combined to create a dataset with 33 rows for each phantom and 792 rows total. At the ML stage, linear (LR), random forest (RF) and support vector regression (SVR) were used. Mean absolute error, mean squared error and accuracy were used to evaluate the performances.

Results: The female phantoms received higher doses (7.8 %) than males. Furthermore, an average of 11 % more dose was taken to the normal weight phantom than to the overweight, the overweight in comparison to the obese I, and the obese I in comparison to the obese II. Among the ML algorithms, the LR showed 0 error rate and 100 % accuracy in predicting CT doses.

Conclusions: The LR was shown to be the best approach out of those used in the ML estimation of CT-induced doses.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
各种计算机断层扫描应用中有效辐射剂量的机器学习预测:虚拟人体模型研究。
目标:在这项工作中,我们的目标是采用机器学习(ML)算法准确预测模型的辐射剂量,同时考虑到最流行的 CT 方案:本研究旨在利用机器学习(ML)算法准确预测模型的辐射剂量,同时考虑到最流行的 CT 方案:利用基于云的软件计算不同 CT 方案的有效剂量。为了模拟一系列不同体重的成年患者,使用了八个基于全身网格的计算模型集。将头部、颈部和胸部-腹部-骨盆 CT 扫描特征组合在一起,创建了一个数据集,每个模型有 33 行,共 792 行。在 ML 阶段,使用了线性回归 (LR)、随机森林回归 (RF) 和支持向量回归 (SVR)。使用平均绝对误差、平均平方误差和准确度来评估性能:女性模型的剂量(7.8%)高于男性。此外,正常体重人体模型的剂量比超重人体模型平均高出 11%,超重人体模型比肥胖 I 型人体模型高出 11%,肥胖 I 型人体模型比肥胖 II 型人体模型高出 11%。在 ML 算法中,LR 预测 CT 剂量的错误率为 0,准确率为 100%:结论:在对 CT 诱导的剂量进行 ML 估算时,LR 被证明是最好的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Advanced deep learning framework for breast cancer detection using digital breast tomosynthesis images. AI in healthcare: mapping Romania's transition from research to intellectual property & industry solutions. CVM-fusion: parallel cross-axes mamba fusion for medical image segmentation. Polysaccharides, as biological macromolecules in the development of tissue engineered tendon and ligament: a review. A novel MOSnet model for multi-object segmentation of medical images in micro-computed tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1