Biofidelity Investigation and Chest Structure Enhancement of Q3 Dummy Restrained in Impact Shield Child Restraint System

IF 5.4 2区 医学 Q3 ENGINEERING, BIOMEDICAL Annals of Biomedical Engineering Pub Date : 2025-04-08 DOI:10.1007/s10439-025-03727-w
Xuerong Zhang, Wanqing Zhang, Jing Gao, Zuhong Tu, Xin Ye, Yang Liu, Wenqiong Tu
{"title":"Biofidelity Investigation and Chest Structure Enhancement of Q3 Dummy Restrained in Impact Shield Child Restraint System","authors":"Xuerong Zhang,&nbsp;Wanqing Zhang,&nbsp;Jing Gao,&nbsp;Zuhong Tu,&nbsp;Xin Ye,&nbsp;Yang Liu,&nbsp;Wenqiong Tu","doi":"10.1007/s10439-025-03727-w","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>The biofidelity of anthropomorphic test devices directly affects the evaluation of safety performance of child restraint systems. The purpose is to enhance the biofidelity of Q3 child dummy by chest structure reconstruction for the accurate prediction of the child injuries during a frontal crash.</p><h3>Methods</h3><p>The finite element model of Q3 child dummy restrained in impact shield child restraint systems was validated through a frontal sled test. Based on the validated sled test simulation models, the comparative biofidelity analyses between Q3 model and PIPER 3-year-old human model were conducted by the quantitative kinematic and biomechanical analyses. The internal chest structure difference between Q3 and PIPER 3-year-old human model is discussed, and the absence of the heart, lungs, and great vessels in the Q3 dummy leads to the low biofidelity; therefore, the chest structure and cardiopulmonary model of Q3 dummy were reconstructed to enhance the biofidelity.</p><h3>Results</h3><p>In comparison to the original Q3 model, the chest deflection, head forward displacement, and neck bending angle of the reconstructed Q3 model increased by 38.5, 2.2, and 17%, respectively, and the upward displacement of the hip decreased by 49%. The head swing degree of the reconstructed Q3 model is dramatically reduced during the rebound process, and the injury assessment criteria of the head, chest, and pelvis can reach more than 95% of the level of the PIPER 3-year-old human model.</p><h3>Conclusions</h3><p>This study shows that the chest reconstruction can significantly improve the biofidelity of the Q3 dummy, and future study is recommended to optimize the spinal structures of the Q3 model for further enhancement of biofidelity.</p></div>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":"53 6","pages":"1486 - 1495"},"PeriodicalIF":5.4000,"publicationDate":"2025-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10439-025-03727-w","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The biofidelity of anthropomorphic test devices directly affects the evaluation of safety performance of child restraint systems. The purpose is to enhance the biofidelity of Q3 child dummy by chest structure reconstruction for the accurate prediction of the child injuries during a frontal crash.

Methods

The finite element model of Q3 child dummy restrained in impact shield child restraint systems was validated through a frontal sled test. Based on the validated sled test simulation models, the comparative biofidelity analyses between Q3 model and PIPER 3-year-old human model were conducted by the quantitative kinematic and biomechanical analyses. The internal chest structure difference between Q3 and PIPER 3-year-old human model is discussed, and the absence of the heart, lungs, and great vessels in the Q3 dummy leads to the low biofidelity; therefore, the chest structure and cardiopulmonary model of Q3 dummy were reconstructed to enhance the biofidelity.

Results

In comparison to the original Q3 model, the chest deflection, head forward displacement, and neck bending angle of the reconstructed Q3 model increased by 38.5, 2.2, and 17%, respectively, and the upward displacement of the hip decreased by 49%. The head swing degree of the reconstructed Q3 model is dramatically reduced during the rebound process, and the injury assessment criteria of the head, chest, and pelvis can reach more than 95% of the level of the PIPER 3-year-old human model.

Conclusions

This study shows that the chest reconstruction can significantly improve the biofidelity of the Q3 dummy, and future study is recommended to optimize the spinal structures of the Q3 model for further enhancement of biofidelity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
防冲击儿童约束系统中Q3假人的生物保真度研究及胸部结构增强。
目的:拟人试验装置的生物保真度直接影响儿童约束系统安全性能的评价。目的是通过胸部结构重建提高Q3儿童假人的生物保真度,以准确预测儿童正面碰撞损伤。方法:通过正面台车试验,对Q3儿童假人的有限元模型进行验证。基于验证的雪橇试验仿真模型,通过定量运动学和生物力学分析,对Q3模型和PIPER 3岁人体模型进行了生物保真度对比分析。讨论了Q3与PIPER 3岁人体模型内部胸部结构的差异,Q3假人缺少心脏、肺和大血管,导致其生物保真度较低;因此,我们重建了Q3假人的胸部结构和心肺模型,以提高其生物保真度。结果:与原Q3模型相比,重建Q3模型的胸部偏转、头部前倾和颈部弯曲角度分别增加38.5%、2.2%和17%,髋部向上位移减少49%。重建的Q3模型在反弹过程中头部摆动度大幅降低,头部、胸部、骨盆损伤评估标准可达到PIPER 3岁人体模型95%以上水平。结论:本研究显示胸部重建可显著提高Q3假人的生物保真度,建议未来研究对Q3模型的脊柱结构进行优化,进一步提高生物保真度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
期刊最新文献
Plant-Based Scaffolds in Tissue Engineering: Structure-Function, Processing, and Clinical Outlook-A Review. Comparative Analysis of Decellularization Protocols for Human Placenta: Balancing Cell Removal with Extracellular Matrix Preservation for Hydrogel Applications. The Effect Of Localized Circumferential Residual Stress On Pressurized Stress State Of CT Reconstructed Vessels: A Finite Element Study. Mechanical Properties of Percutaneous Transluminal Coronary Angioplasty Balloon Catheters: A Bench Study. Linguistic, Orthographic, and Typographical Errors in Science (LOTS): A Growing Threat to Academic Integrity.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1