Interreader Agreement of Lung-RADS: A Systematic Review and Meta-Analysis.

IF 6.1 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING American Journal of Roentgenology Pub Date : 2025-06-01 Epub Date: 2025-06-18 DOI:10.2214/AJR.25.32681
Jisun Hwang, Pyeong Hwa Kim, Seulgi You, You Na Kim, Joo Sung Sun
{"title":"Interreader Agreement of Lung-RADS: A Systematic Review and Meta-Analysis.","authors":"Jisun Hwang, Pyeong Hwa Kim, Seulgi You, You Na Kim, Joo Sung Sun","doi":"10.2214/AJR.25.32681","DOIUrl":null,"url":null,"abstract":"<p><p><b>BACKGROUND</b>. Lung-RADS has shown variable interreader agreement in the literature, in part related to a broad range of factors that may influence the consistency of its implementation. <b>OBJECTIVE</b>. The purpose of this study was to assess the interreader agreement of Lung-RADS and to investigate factors influencing the system's variability. <b>EVIDENCE ACQUISITION</b>. The Embase, PubMed, and Cochrane databases were searched for original research studies published through June 18, 2024, that reported the interreader agreement of Lung-RADS on chest CT. Random-effects models were used to calculate pooled kappa coefficients for Lung-RADS categorization and pooled intraclass correlation coefficients (ICCs) for nodule size measurements. Potential sources of heterogeneity were explored using metaregression analyses. <b>EVIDENCE SYNTHESIS</b>. The analysis included 11 studies (1470 patients) for Lung-RADS categorization and five studies (617 patients) for nodule size measurement. Interreader agreement for Lung-RADS categorization was substantial (κ = 0.72 [95% CI, 0.57-0.82]), and that for nodule size measurement was almost perfect (ICC = 0.97 [95% CI, 0.90-0.99]). Interreader agreement for Lung-RADS categorization was significantly associated with the method of nodule measurement (<i>p</i> = .005), with pooled kappa coefficients of 0.95, 0.91, and 0.66 for studies using computer-aided detection (CAD)-based semiautomated volume measurements, CAD-based semiautomated diameter measurements, and manual diameter measurements, respectively. Interreader agreement for Lung-RADS categorization was also significantly associated with studies' nodule type distribution (<i>p</i> < .001), with pooled kappa coefficients of 0.85, 0.76, and 0.55 for studies evaluating 100% solid nodules, 30-99% solid nodules, and fewer than 30% solid nodules, respectively. Interreader agreement for nodule size measurement was significantly associated with radiation dose (<i>p</i> < .001), with pooled ICCs of 0.97, 0.96, and 0.59 for studies that used standard-dose CT, low-dose CT, and ultralow-dose CT, respectively. Interreader agreement for nodule size measurement was also significantly associated with the Lung-RADS version that was used (<i>p</i> = .02), with pooled ICCs of 0.99 and 0.93 for studies using Lung-RADS 1.1 and Lung-RADS 1.0, respectively. <b>CONCLUSION</b>. Although they support the overall reliability of Lung-RADS, the findings indicate roles for CAD assistance as well as training and standardized approaches for nodule type characterization to further promote reproducible application. <b>CLINICAL IMPACT</b>. Consistent nodule assessments will be critical for Lung-RADS to optimally impact patient management and outcomes.</p>","PeriodicalId":55529,"journal":{"name":"American Journal of Roentgenology","volume":" ","pages":"e2532681"},"PeriodicalIF":6.1000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Roentgenology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2214/AJR.25.32681","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND. Lung-RADS has shown variable interreader agreement in the literature, in part related to a broad range of factors that may influence the consistency of its implementation. OBJECTIVE. The purpose of this study was to assess the interreader agreement of Lung-RADS and to investigate factors influencing the system's variability. EVIDENCE ACQUISITION. The Embase, PubMed, and Cochrane databases were searched for original research studies published through June 18, 2024, that reported the interreader agreement of Lung-RADS on chest CT. Random-effects models were used to calculate pooled kappa coefficients for Lung-RADS categorization and pooled intraclass correlation coefficients (ICCs) for nodule size measurements. Potential sources of heterogeneity were explored using metaregression analyses. EVIDENCE SYNTHESIS. The analysis included 11 studies (1470 patients) for Lung-RADS categorization and five studies (617 patients) for nodule size measurement. Interreader agreement for Lung-RADS categorization was substantial (κ = 0.72 [95% CI, 0.57-0.82]), and that for nodule size measurement was almost perfect (ICC = 0.97 [95% CI, 0.90-0.99]). Interreader agreement for Lung-RADS categorization was significantly associated with the method of nodule measurement (p = .005), with pooled kappa coefficients of 0.95, 0.91, and 0.66 for studies using computer-aided detection (CAD)-based semiautomated volume measurements, CAD-based semiautomated diameter measurements, and manual diameter measurements, respectively. Interreader agreement for Lung-RADS categorization was also significantly associated with studies' nodule type distribution (p < .001), with pooled kappa coefficients of 0.85, 0.76, and 0.55 for studies evaluating 100% solid nodules, 30-99% solid nodules, and fewer than 30% solid nodules, respectively. Interreader agreement for nodule size measurement was significantly associated with radiation dose (p < .001), with pooled ICCs of 0.97, 0.96, and 0.59 for studies that used standard-dose CT, low-dose CT, and ultralow-dose CT, respectively. Interreader agreement for nodule size measurement was also significantly associated with the Lung-RADS version that was used (p = .02), with pooled ICCs of 0.99 and 0.93 for studies using Lung-RADS 1.1 and Lung-RADS 1.0, respectively. CONCLUSION. Although they support the overall reliability of Lung-RADS, the findings indicate roles for CAD assistance as well as training and standardized approaches for nodule type characterization to further promote reproducible application. CLINICAL IMPACT. Consistent nodule assessments will be critical for Lung-RADS to optimally impact patient management and outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肺- rads的解读者一致:系统回顾和荟萃分析。
背景:Lung-RADS在文献中表现出不同的解读者一致性,部分与可能影响其实施一致性的广泛因素有关。目的:评价肺- rads的判读一致性,探讨影响该系统变异性的因素。证据获取:检索EMBASE、PubMed和Cochrane数据库,检索截至2024年6月18日发表的原始研究,报告肺部rads在胸部CT上的解读一致。随机效应模型用于计算肺- rads分类的合并kappa系数和测量结节大小的合并类内相关系数。利用元回归分析探讨了异质性的潜在来源。证据综合:该分析包括11项研究(1470例患者)肺- rads分类和5项研究(617例患者)结节大小测量。肺- rads分类的解读器一致性很高(κ=0.72 [95% CI, 0.57-0.82]),结节大小测量的解读器一致性几乎完全(ICC=0.97 [95% CI, 0.90-0.99])。肺- rads分类的解读器一致性与结节测量方法显著相关(p= 0.005),基于计算机辅助检测(CAD)的半自动体积测量、基于CAD的半自动直径测量和人工直径测量的kappa系数分别为0.95、0.91和0.66。结论:在支持Lung-RADS总体可靠性的同时,研究结果表明CAD辅助以及培训和标准化方法对结节类型表征的作用,以进一步促进可重复性应用。临床影响:一致的结节评估对于肺- rads至关重要,以最佳地影响患者管理和结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
12.80
自引率
4.00%
发文量
920
审稿时长
3 months
期刊介绍: Founded in 1907, the monthly American Journal of Roentgenology (AJR) is the world’s longest continuously published general radiology journal. AJR is recognized as among the specialty’s leading peer-reviewed journals and has a worldwide circulation of close to 25,000. The journal publishes clinically-oriented articles across all radiology subspecialties, seeking relevance to radiologists’ daily practice. The journal publishes hundreds of articles annually with a diverse range of formats, including original research, reviews, clinical perspectives, editorials, and other short reports. The journal engages its audience through a spectrum of social media and digital communication activities.
期刊最新文献
The Global Reading Room: Radiology, Then and Now. Extensive Continuous Pulmonary Cement Embolism. Spectral Photon-Counting Detector Coronary CTA With Reduced Radiation and Contrast Medium Dose in Inflammation-Associated Coronary Artery Disease: A Prospective Study. Echogenic Rind Associated With Suspicious Masses on Ultrasound: Performance for Breast Cancer Diagnosis and Associations With Pathologic Tumor Characteristics. Another Instrument to Improve Breast Cancer Outcomes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1