J C Böck, P Deuflhard, A Hoeft, H Korb, J Steinmann, H G Wolpers, G Hellige
{"title":"Evaluation of monoexponential extrapolation of transpulmonary thermal-dye kinetics by use of a new model-free deconvolution algorithm.","authors":"J C Böck, P Deuflhard, A Hoeft, H Korb, J Steinmann, H G Wolpers, G Hellige","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluates the routine mathematic approach (monoexponential extrapolation) for analysis of transpulmonary thermal-dye dilution curves and estimates the effects of systemic-indicator recirculation by use of a deconvolution technique. Fifteen dogs anesthetized with N2O-piritramid were studied before and after induction of pulmonary edema by oleic acid. After introduction of central venous indicator (10 ml of a mixture of cold blood and indocyanine green dye), dilution data were recorded from the pulmonary artery and the ascending aorta. The conclusions were: (1) monoexponential extrapolation yields reasonably good estimates of the mean transit times of dye; (2) mean transit times of heat are usually overestimated by monoexponential extrapolation; (3) extravascular lung thermal volume assessed by monoexponential extrapolation is overestimated by 2.03 ml/kg of body mass under baseline conditions; and (4) the prepulmonary volume of distribution of heat exceeds that of dye by 1.4 ml/kg of body mass, thus increasing the overestimation of pulmonary extravascular heat-accessible space by the conventional technique.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 1","pages":"20-8"},"PeriodicalIF":0.0000,"publicationDate":"1988-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical instrumentation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This study evaluates the routine mathematic approach (monoexponential extrapolation) for analysis of transpulmonary thermal-dye dilution curves and estimates the effects of systemic-indicator recirculation by use of a deconvolution technique. Fifteen dogs anesthetized with N2O-piritramid were studied before and after induction of pulmonary edema by oleic acid. After introduction of central venous indicator (10 ml of a mixture of cold blood and indocyanine green dye), dilution data were recorded from the pulmonary artery and the ascending aorta. The conclusions were: (1) monoexponential extrapolation yields reasonably good estimates of the mean transit times of dye; (2) mean transit times of heat are usually overestimated by monoexponential extrapolation; (3) extravascular lung thermal volume assessed by monoexponential extrapolation is overestimated by 2.03 ml/kg of body mass under baseline conditions; and (4) the prepulmonary volume of distribution of heat exceeds that of dye by 1.4 ml/kg of body mass, thus increasing the overestimation of pulmonary extravascular heat-accessible space by the conventional technique.