An aerosol generator system for inhalation delivery of pharmacologic agents.

Medical instrumentation Pub Date : 1987-06-01
A A Strong, M J Hazucha, D A Lundgren, E R Cerini
{"title":"An aerosol generator system for inhalation delivery of pharmacologic agents.","authors":"A A Strong,&nbsp;M J Hazucha,&nbsp;D A Lundgren,&nbsp;E R Cerini","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Most commercially available aerosol generators widely used in medical applications produce aerosols characterized by a large mass median diameter in the 4-8 micron range and the particle size in the 0.1-10.0 microns range. The desirable size of therapeutic and diagnostic aerosols, however, is about 2-4 microns mass median diameter, and less than 2.0 geometric standard deviation; this size increases the reproducibility of inhalation tests and enhances drug efficacy. We combined the commercially available DeVilbiss Model 65 nebulizer with a dilution/mixing chamber developed in our laboratory. The characteristics of this aerosol generator system were examined over a range of operating conditions and concentrations of solutions of three bronchoconstrictive agents--histamine, carbachol, and methacholine. The aerosol generator system produced a polydispersed aerosol with a mass median diameter range of 1.7-2.4 microns and geometric standard deviation of 1.5. The reliable and reproducible operation of the aerosol generator system greatly increases the power of bronchial challenge tests with bronchoconstrictive drugs.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 3","pages":"189-94"},"PeriodicalIF":0.0000,"publicationDate":"1987-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical instrumentation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Most commercially available aerosol generators widely used in medical applications produce aerosols characterized by a large mass median diameter in the 4-8 micron range and the particle size in the 0.1-10.0 microns range. The desirable size of therapeutic and diagnostic aerosols, however, is about 2-4 microns mass median diameter, and less than 2.0 geometric standard deviation; this size increases the reproducibility of inhalation tests and enhances drug efficacy. We combined the commercially available DeVilbiss Model 65 nebulizer with a dilution/mixing chamber developed in our laboratory. The characteristics of this aerosol generator system were examined over a range of operating conditions and concentrations of solutions of three bronchoconstrictive agents--histamine, carbachol, and methacholine. The aerosol generator system produced a polydispersed aerosol with a mass median diameter range of 1.7-2.4 microns and geometric standard deviation of 1.5. The reliable and reproducible operation of the aerosol generator system greatly increases the power of bronchial challenge tests with bronchoconstrictive drugs.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于吸入输送药理学制剂的气溶胶发生器系统。
在医疗应用中广泛使用的大多数市售气溶胶发生器产生的气溶胶的特点是质量中值直径在4-8微米范围内,粒径在0.1-10.0微米范围内。然而,治疗和诊断气溶胶的理想尺寸是大约2-4微米的质量中位数直径,小于2.0几何标准偏差;这种尺寸增加了吸入试验的可重复性,提高了药物功效。我们将市售的DeVilbiss 65型雾化器与我们实验室开发的稀释/混合室相结合。在一系列操作条件和三种支气管收缩剂(组胺、氨基酚和甲胆碱)溶液的浓度下,研究了这种气溶胶发生器系统的特性。气溶胶产生系统产生的多分散气溶胶的质量中位数直径范围为1.7-2.4微米,几何标准偏差为1.5。气溶胶发生器系统的可靠和可重复性大大提高了支气管收缩药物支气管激发试验的功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Physical fitness in the elderly. Anesthesia delivery systems. Effects of using potassium adsorption filters on saline-filled and saline-removed methods for the removal of potassium from red blood cell solutions Plasma viscosity and whole blood viscosity as diagnostic tools of blood abnormalities by using simple syringe method A technique for measuring spatial distribution of electromagnetic fields created by radio-frequency coils in MRI scanners
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1