Evaluation of intrusive mechanics of the type “segmented arch” on a macerated human skull using the laser reflection technique and holographic interferometry

Luc R. Dermaut D.D.S., Ph.D. , Marc M. Vanden Bulcke D.D.S
{"title":"Evaluation of intrusive mechanics of the type “segmented arch” on a macerated human skull using the laser reflection technique and holographic interferometry","authors":"Luc R. Dermaut D.D.S., Ph.D. ,&nbsp;Marc M. Vanden Bulcke D.D.S","doi":"10.1016/0002-9416(86)90041-2","DOIUrl":null,"url":null,"abstract":"<div><p>Twelve different systems of intrusion, based on the principle of the “segmented arch,” were evaluated on a macerated human skull. The number of teeth involved in the anterior unit and the location of the application points of intrusive force were considered to be variables. Initial displacements of the anterior teeth after loading were registered by means of the laser reflection technique and double exposure holographic recordings. An attempt was made to define “this” intrusive system, achieving the most genuine intrusion (for definition, see text) without flaring of the teeth. When two central incisors were incorporated in the sectional wire, strong torque forces appeared, especially when the intrusive forces seized more distally. When four or six anterior teeth were pinned in the sectional wire, tooth movement seemed to be under better control. When the six front teeth were incorporated in the sectional wire, the center of resistance (for definition, see text) was located more to the distal side of the canines. It seemed more difficult, however, to define the center of resistance of the four incisors; it was situated approximately distal to the lateral incisors. In some of the intrusive systems, the teeth underwent independent mesial or distal rotations. This was easily observed with the laser measuring techniques used.</p></div>","PeriodicalId":75476,"journal":{"name":"American journal of orthodontics","volume":"89 3","pages":"Pages 251-263"},"PeriodicalIF":0.0000,"publicationDate":"1986-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0002-9416(86)90041-2","citationCount":"51","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0002941686900412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 51

Abstract

Twelve different systems of intrusion, based on the principle of the “segmented arch,” were evaluated on a macerated human skull. The number of teeth involved in the anterior unit and the location of the application points of intrusive force were considered to be variables. Initial displacements of the anterior teeth after loading were registered by means of the laser reflection technique and double exposure holographic recordings. An attempt was made to define “this” intrusive system, achieving the most genuine intrusion (for definition, see text) without flaring of the teeth. When two central incisors were incorporated in the sectional wire, strong torque forces appeared, especially when the intrusive forces seized more distally. When four or six anterior teeth were pinned in the sectional wire, tooth movement seemed to be under better control. When the six front teeth were incorporated in the sectional wire, the center of resistance (for definition, see text) was located more to the distal side of the canines. It seemed more difficult, however, to define the center of resistance of the four incisors; it was situated approximately distal to the lateral incisors. In some of the intrusive systems, the teeth underwent independent mesial or distal rotations. This was easily observed with the laser measuring techniques used.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用激光反射技术和全息干涉测量法评价浸渍人头骨“分段弓”型的侵入力学
基于“分段弓”原理的12种不同的侵入系统在浸渍的人类头骨上进行了评估。前单元受累的牙数和施加侵入力点的位置被认为是变量。采用激光反射技术和双曝光全息记录技术记录了前牙加载后的初始位移。人们试图定义“这种”侵入系统,实现最真实的侵入(关于定义,见文本),而不会使牙齿凸出。当两个中切牙合并在截面线时,出现了强烈的扭矩力,特别是当侵入力在较远端抓住时。当将4 ~ 6颗前牙固定在断层钢丝上时,牙齿的运动似乎得到了更好的控制。当六颗门牙被纳入截面金属丝时,阻力中心(定义见文)更多地位于犬齿的远端。然而,要确定四个门牙的阻力中心似乎比较困难;它大约位于侧门牙的远端。在一些侵入系统中,牙齿进行独立的近端或远端旋转。使用激光测量技术很容易观察到这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Innovations in Public Financing for Family Planning at Subnational Levels: Sustainable Cofinancing Strategies for Family Planning With Nigerian States. Man of the Year Participation of a coordinating center pharmacy in a multicenter international study. The agitation-activity interface of people with dementia in long-term care. Gap-junctional communication between feeder cells and recipient normal epithelial cells correlates with growth stimulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1