Vascular enhancement during incremental body computed tomography. A simple and reliable technique.

U Nyman, G Dinnetz
{"title":"Vascular enhancement during incremental body computed tomography. A simple and reliable technique.","authors":"U Nyman,&nbsp;G Dinnetz","doi":"10.1177/028418518602700608","DOIUrl":null,"url":null,"abstract":"<p><p>An initial manual bolus injection of contrast medium to an amount of 15 g iodine immediately followed by a manual infusion of 25 to 35 g iodine during 3 to 5 minutes will provide proper enhancement of vascular structures (110-150 HU) at incremental body computed tomography during that time and for some minutes after the end of the infusion. This technique applied in more than 1,000 examinations proved it to be reliable, simple and fast. A computed tomograph allowing 3 scans per minute permits an adequate and even level of vascular enhancement of the entire neck, mediastinum, abdomen or pelvis when continuous or more sparse slices of about 10 mm thickness are used. When the images are reconstructed without delay and presented on a monitor in the scanning suite, it is possible to individually optimize the rate of infusion and thereby also minimize the amount of contrast medium. A prerequisite for a proper vascular enhancement is a high rate of infusion initially.</p>","PeriodicalId":7142,"journal":{"name":"Acta radiologica: diagnosis","volume":"27 6","pages":"667-73"},"PeriodicalIF":0.0000,"publicationDate":"1986-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/028418518602700608","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/028418518602700608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

An initial manual bolus injection of contrast medium to an amount of 15 g iodine immediately followed by a manual infusion of 25 to 35 g iodine during 3 to 5 minutes will provide proper enhancement of vascular structures (110-150 HU) at incremental body computed tomography during that time and for some minutes after the end of the infusion. This technique applied in more than 1,000 examinations proved it to be reliable, simple and fast. A computed tomograph allowing 3 scans per minute permits an adequate and even level of vascular enhancement of the entire neck, mediastinum, abdomen or pelvis when continuous or more sparse slices of about 10 mm thickness are used. When the images are reconstructed without delay and presented on a monitor in the scanning suite, it is possible to individually optimize the rate of infusion and thereby also minimize the amount of contrast medium. A prerequisite for a proper vascular enhancement is a high rate of infusion initially.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
递增体计算机断层扫描时血管增强。一种简单可靠的技术。
在此期间和输注结束后的几分钟内,首先手动大剂量注射造影剂15g碘,然后在3 - 5分钟内手动输注25 - 35g碘,可在增量体计算机断层扫描中提供血管结构(110- 150hu)的适当增强。在1000多次试验中证明了该方法可靠、简便、快速。每分钟扫描3次的计算机断层扫描,当使用约10mm厚度的连续或更稀疏的切片时,可以充分且均匀地增强整个颈部、纵隔、腹部或骨盆的血管。当图像无延迟地重建并显示在扫描套件的监视器上时,可以单独优化输注速率,从而也可以最小化造影剂的量。适当的血管增强的先决条件是初始的高输注速率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Importance Du Volume Irradié Et Notion De Dose Dans Le Traitement Post-Opératoire Des Tumeurs Cérébrales Treatment of Neuroblastoma RADIATION LOAD TO THE GONADS IN DIAGNOSTIC AND THERAPEUTIC PROCEDURES Effect of Cyclophosphamide on Pain in Advanced Carcinoma of the Cervix Cesium 137 Burdens in the Canadian North
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1