Quantitative vascular casting of the post-ischemic hydronephrotic kidney.

Scanning electron microscopy Pub Date : 1986-01-01
V H Gattone, R D Sale
{"title":"Quantitative vascular casting of the post-ischemic hydronephrotic kidney.","authors":"V H Gattone,&nbsp;R D Sale","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The renal microvasculature (afferent arteriole) and glomeruli were examined and quantitated by two methods in the post-ischemic hydronephrotic (PIH) kidney. The methods used were: an in vivo examination and controlled perfusion-fixation, quantitative vascular casting examined by scanning electron microscopy. The second method was also applied to the vasculature of the contralateral, functional kidney. The goals of the study were to: validate the quantitative vascular casting method by comparing PIH renal microvascular data from the casting method with in vivo values and determine the extent of microvascular dimensional difference of the PIH kidney from its contralateral functional counterpart. It was determined that the casting values were consistent with the data obtained from the in vivo examination of the afferent arteriole and glomeruli. This finding provides further support for the quantitative renal microvascular casting technique. Using that technique it was determined that the dimensions of the microvasculature and glomeruli of the PIH kidney were severely (and significantly, p less than 0.05) reduced compared to its functional mate. Since these PIH vessels show a significant decrement in size, vascular reactivity and functional data based on the PIH vessels should be looked at cautiously. The vasculature and glomeruli of the PIH kidney might not be totally normal, however structurally, the glomeruli do not appear to be dramatically altered.</p>","PeriodicalId":21455,"journal":{"name":"Scanning electron microscopy","volume":" Pt 2","pages":"549-56"},"PeriodicalIF":0.0000,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scanning electron microscopy","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The renal microvasculature (afferent arteriole) and glomeruli were examined and quantitated by two methods in the post-ischemic hydronephrotic (PIH) kidney. The methods used were: an in vivo examination and controlled perfusion-fixation, quantitative vascular casting examined by scanning electron microscopy. The second method was also applied to the vasculature of the contralateral, functional kidney. The goals of the study were to: validate the quantitative vascular casting method by comparing PIH renal microvascular data from the casting method with in vivo values and determine the extent of microvascular dimensional difference of the PIH kidney from its contralateral functional counterpart. It was determined that the casting values were consistent with the data obtained from the in vivo examination of the afferent arteriole and glomeruli. This finding provides further support for the quantitative renal microvascular casting technique. Using that technique it was determined that the dimensions of the microvasculature and glomeruli of the PIH kidney were severely (and significantly, p less than 0.05) reduced compared to its functional mate. Since these PIH vessels show a significant decrement in size, vascular reactivity and functional data based on the PIH vessels should be looked at cautiously. The vasculature and glomeruli of the PIH kidney might not be totally normal, however structurally, the glomeruli do not appear to be dramatically altered.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
缺血后肾积水定量血管铸型。
采用两种方法对缺血肾水性肾病(PIH)后肾微血管(传入小动脉)和肾小球进行检测和定量。方法为:体内检查和控制灌注固定,扫描电镜定量观察血管铸型。第二种方法也适用于对侧功能肾脏的血管系统。本研究的目的是:通过比较铸型法获得的PIH肾微血管数据与体内值,验证定量血管铸型方法,并确定PIH肾与对侧功能肾的微血管尺寸差异程度。经测定,铸型值与传入小动脉和肾小球体内检查所得数据一致。这一发现为肾微血管定量铸造技术提供了进一步的支持。使用该技术,可以确定PIH肾脏的微血管和肾小球的尺寸与其功能伴侣相比严重(且显著,p < 0.05)减小。由于这些PIH血管的大小明显减小,因此应谨慎看待基于PIH血管的血管反应性和功能数据。PIH肾的脉管系统和肾小球可能不完全正常,但肾小球在结构上没有明显改变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
FE-SEM Characterization of Some Nanomaterial Rare Pathological Findings Long term effects of radiation and combined modalities on mouse lung. Characterization of mucus glycoconjugates in normal human conjunctiva by lectins in light microscopy, transmission and scanning electron microscopy. The study of biominerals by high resolution transmission electron microscopy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1