{"title":"Hemodialyzer reuse: practices in the United States and implication for infection control.","authors":"L Bland,&nbsp;M Alter,&nbsp;M Favero,&nbsp;L Carson,&nbsp;L Cusick","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Reuse of hemodialyzers has continued to increase dramatically. In 1983, 52% of the hemodialysis centers were reusing hemodialyzers. Use of hollow fiber hemodialyzers has paralleled this increase in hemodialyzer reuse with 63% of the hemodialysis centers reporting exclusive use of this type of hemodialyzer in 1983. Although reuse of hemodialyzers has not been associated with increased incidence of hepatitis B infection or pyrogenic reactions, an outbreak of nontuberculous mycobacteria in 27 chronic hemodialysis patients was probably associated with water used to reprocess dialyzers. Nontuberculous mycobacteria were isolated from the water in 83% of 115 hemodialysis centers surveyed across the United States and could constitute a potential infection risk because of the organisms' greater germicide resistance than most other naturally occurring water bacteria. Two percent formaldehyde is not an effective germicide for high level disinfection of hemodialyzers. Reprocessed hemodialyzers should be disinfected with 4% formaldehyde or an equivalent disinfectant.</p>","PeriodicalId":23160,"journal":{"name":"Transactions - American Society for Artificial Internal Organs","volume":"31 ","pages":"556-9"},"PeriodicalIF":0.0000,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions - American Society for Artificial Internal Organs","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Reuse of hemodialyzers has continued to increase dramatically. In 1983, 52% of the hemodialysis centers were reusing hemodialyzers. Use of hollow fiber hemodialyzers has paralleled this increase in hemodialyzer reuse with 63% of the hemodialysis centers reporting exclusive use of this type of hemodialyzer in 1983. Although reuse of hemodialyzers has not been associated with increased incidence of hepatitis B infection or pyrogenic reactions, an outbreak of nontuberculous mycobacteria in 27 chronic hemodialysis patients was probably associated with water used to reprocess dialyzers. Nontuberculous mycobacteria were isolated from the water in 83% of 115 hemodialysis centers surveyed across the United States and could constitute a potential infection risk because of the organisms' greater germicide resistance than most other naturally occurring water bacteria. Two percent formaldehyde is not an effective germicide for high level disinfection of hemodialyzers. Reprocessed hemodialyzers should be disinfected with 4% formaldehyde or an equivalent disinfectant.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血液透析器再利用:美国的做法及其对感染控制的影响。
血液透析器的重复使用继续显著增加。1983年,52%的血液透析中心重复使用血液透析器。中空纤维血液透析器的使用与血液透析器重复使用的增加是平行的,63%的血液透析中心报告在1983年只使用这种类型的血液透析器。虽然血液透析器的重复使用与乙型肝炎感染或热原反应的发生率增加无关,但在27名慢性血液透析患者中爆发的非结核分枝杆菌可能与用于透析器再加工的水有关。在美国调查的115个血液透析中心中,有83%从水中分离出了非结核分枝杆菌,由于这种微生物比大多数其他天然存在的水细菌具有更大的杀菌剂耐药性,因此可能构成潜在的感染风险。对于血液透析器的高水平消毒,2%的甲醛不是有效的杀菌剂。再加工的血液透析器应用4%甲醛或同等消毒剂消毒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of occlusive inlet pannus formation: comparison of conduit designs. Automatic priming, blood flow control, and rinsing during single access hemodialysis: the BioLogic-HD. Reduction in peritonitis frequency by the Dupont Sterile Connection Device. Zirconium does not produce osteomalacia in rats with chronic renal failure. Pathologic findings and their implications in patients managed with temporary ventricular assist.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1