Temperature regulation during treadmill exercise in the rat.

F G Shellock, S A Rubin
{"title":"Temperature regulation during treadmill exercise in the rat.","authors":"F G Shellock,&nbsp;S A Rubin","doi":"10.1152/jappl.1984.57.6.1872","DOIUrl":null,"url":null,"abstract":"<p><p>The response of colonic and tail-skin temperatures to treadmill exercise was assessed in female Sprague-Dawley rats using incremental and single-stage exercise protocols to investigate the relationship between deep body temperature and work rate. O2 uptake (VO2) was measured by flow-through technique to evaluate the exercise intensity. Experiments were performed in ambient temperatures below (22-25 degrees C) and above (33-35 degrees C) the thermoneutral zone of the rat. During graded incremental exercise there was a linear relationship between colonic temperature (Tco) and VO2 in both the cooler and warmer ambient temperatures. However, Tco and tail-skin temperature (Tsk) at comparable work rates in the cooler and warmer environments were 40.22 +/- 0.59, 34.84 +/- 1.10 degrees C and 42.04 +/- 0.57, 38.39 +/- 1.54 degrees C, indicating that the rise in Tco was unrelated to the severity of exercise. During single-stage exercise the rats were able to achieve thermal equilibrium but only at low work rates and in the cool environment (22-25 degrees C). There were no significant differences in Tco at the first three levels of single-stage exercise (stage 1, 39.63 +/- 0.34 degrees C; stage 2, 39.67 +/- 0.49 degrees C; stage 3, 39.75 +/- 0.50 degrees C) despite significant differences in VO2 (stage 1, 4.3 +/- 0.7 ml X min-1 X 100 g-1; stage 2, 5.3 +/- 0.6 ml X min X 100 g-1; stage 3, 7.6 +/- 1.2 ml X min-1 X 100 g-1). This demonstrates that there was no relationship between the level of Tco maintained during exercise and the work intensity.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":15258,"journal":{"name":"Journal of applied physiology: respiratory, environmental and exercise physiology","volume":"57 6","pages":"1872-7"},"PeriodicalIF":0.0000,"publicationDate":"1984-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1152/jappl.1984.57.6.1872","citationCount":"50","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied physiology: respiratory, environmental and exercise physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1152/jappl.1984.57.6.1872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 50

Abstract

The response of colonic and tail-skin temperatures to treadmill exercise was assessed in female Sprague-Dawley rats using incremental and single-stage exercise protocols to investigate the relationship between deep body temperature and work rate. O2 uptake (VO2) was measured by flow-through technique to evaluate the exercise intensity. Experiments were performed in ambient temperatures below (22-25 degrees C) and above (33-35 degrees C) the thermoneutral zone of the rat. During graded incremental exercise there was a linear relationship between colonic temperature (Tco) and VO2 in both the cooler and warmer ambient temperatures. However, Tco and tail-skin temperature (Tsk) at comparable work rates in the cooler and warmer environments were 40.22 +/- 0.59, 34.84 +/- 1.10 degrees C and 42.04 +/- 0.57, 38.39 +/- 1.54 degrees C, indicating that the rise in Tco was unrelated to the severity of exercise. During single-stage exercise the rats were able to achieve thermal equilibrium but only at low work rates and in the cool environment (22-25 degrees C). There were no significant differences in Tco at the first three levels of single-stage exercise (stage 1, 39.63 +/- 0.34 degrees C; stage 2, 39.67 +/- 0.49 degrees C; stage 3, 39.75 +/- 0.50 degrees C) despite significant differences in VO2 (stage 1, 4.3 +/- 0.7 ml X min-1 X 100 g-1; stage 2, 5.3 +/- 0.6 ml X min X 100 g-1; stage 3, 7.6 +/- 1.2 ml X min-1 X 100 g-1). This demonstrates that there was no relationship between the level of Tco maintained during exercise and the work intensity.(ABSTRACT TRUNCATED AT 250 WORDS)

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
大鼠在跑步机上运动时的体温调节。
采用渐进式和单阶段运动方案,对雌性Sprague-Dawley大鼠的结肠和尾部皮肤温度对跑步机运动的反应进行了评估,以研究深体温与工作速率之间的关系。通过血流技术测定氧摄取(VO2),评价运动强度。实验在环境温度低于(22-25℃)和高于(33-35℃)大鼠的热中性区进行。在渐进式运动中,无论在较冷的环境温度还是较热的环境温度下,结肠温度(Tco)和VO2之间都存在线性关系。然而,在较冷和较暖的环境中,Tco和尾皮温度(Tsk)在相同的工作速率下分别为40.22 +/- 0.59、34.84 +/- 1.10℃和42.04 +/- 0.57、38.39 +/- 1.54℃,表明Tco的升高与运动的严重程度无关。在单阶段运动中,大鼠能够达到热平衡,但只有在低工作速率和凉爽环境(22-25℃)下。在单阶段运动的前三个水平(阶段1,39.63 +/- 0.34℃;阶段2,39.67 +/- 0.49℃;第3阶段,39.75 +/- 0.50℃),尽管VO2有显著差异(第1阶段,4.3 +/- 0.7 ml X min-1 X 100 g-1;第二阶段,5.3 +/- 0.6 ml X min X 100 g-1;第三阶段,7.6 +/- 1.2 ml X min-1 X 100 g-1)。这表明运动期间维持的Tco水平与工作强度之间没有关系。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Exercise, Respiratory and Environmental Physiology: A Tribute from the School of Milano Positive end-expiratory pressure decreases bronchial blood flow in the dog. Effect of slightly lowered body temperatures on endurance performance in humans. Distribution and quantitative developmental changes in guinea pig pulmonary beta-receptors. Effect of beta-adrenergic blockade on lactate turnover in exercising dogs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1