Biotelemetry in local clearance studies with radionuclides using cadmium telluride detectors.

Biotelemetry and patient monitoring Pub Date : 1982-01-01
J Bojsen, B Staberg, K Kølendorf
{"title":"Biotelemetry in local clearance studies with radionuclides using cadmium telluride detectors.","authors":"J Bojsen,&nbsp;B Staberg,&nbsp;K Kølendorf","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Small, gamma-sensitive, cadmium-telluride [CdTe(C1)] detectors are evaluated for biotelemetry of the local clearance of an injected radioactive depot in tissue. The lateral displacement dependence and depth dependence are determined with 99mTc as radiation source. Perspex is used as attenuation and scattering medium. With 133Xe injected into subcutaneous tissue the effect of a geometrical adjustment of the CdTe(C1) detector prior to measurement is studied. Examples of 133Xe disappearance curves are shown during rest and ergometry bicycling.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"9 3","pages":"144-53"},"PeriodicalIF":0.0000,"publicationDate":"1982-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Small, gamma-sensitive, cadmium-telluride [CdTe(C1)] detectors are evaluated for biotelemetry of the local clearance of an injected radioactive depot in tissue. The lateral displacement dependence and depth dependence are determined with 99mTc as radiation source. Perspex is used as attenuation and scattering medium. With 133Xe injected into subcutaneous tissue the effect of a geometrical adjustment of the CdTe(C1) detector prior to measurement is studied. Examples of 133Xe disappearance curves are shown during rest and ergometry bicycling.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用碲化镉探测器进行放射性核素局部清除研究中的生物遥测。
小型,γ敏感,碲化镉[CdTe(C1)]探测器被评估为生物遥测局部清除注射放射性库在组织中。以99mTc为辐射源,确定了横向位移依赖关系和深度依赖关系。采用有机玻璃作为衰减和散射介质。将133Xe注入皮下组织,研究了测量前对CdTe(C1)检测器进行几何调整的效果。给出了在休息和几何骑车时133Xe消失曲线的例子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pulmonary atresia and transposition of the great arteries. Monitoring of the transcutaneous oxygen tension during palliative measures in two cases. Transcutaneous PO2 monitoring in routine observation of newborns. An on-line computer system for monitoring respiratory and cardiac functions of patients. Effect of electrode temperatures on monitoring of transcutaneous carbon dioxide (TcPCO2) in prematures. Monitoring of PCO2 by skin surface sensors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1