{"title":"Correlation technique and its application in the His bundle electrocardiogram.","authors":"X S Wang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In literature, the HBE has been displayed by application of the averaging method. In this paper, correlation analysis technique was used and the body-surface HBE was displayed in a special-purpose electronic computer. The correlation coefficients of the P-A, A-H, H-V intervals and the H-wave width of both methods are almost equivalent and one can be substituted by the other. Compared with the averaging method, the S/N ratio of the correlation method is greater and the residual noise is nearly absent. Furthermore, the effects of the integrating time T and delay time delta tau on the S/N ratio, the measuring resolution and the analytical time have been studied. Correlation analysis technique is a method based on the cybernetic and information theory. With this technique, by using correlation function, the dependence (auto-correlation function) of the value at one instant upon that of the other during the same random process, or the interdependence between sets of data from 2 random processes can be described. Up to the present, there has been no report on the activities of the ventricular conductive system with the S/N ratio smaller than 1, detected on the body surface by correlation analysis technique[1 - 3]. However, using this technique, the author successfully detected the body surface HBE with a special-purpose mini-computer in 1977.</p>","PeriodicalId":21694,"journal":{"name":"Scientia Sinica","volume":"23 12","pages":"1599-607"},"PeriodicalIF":0.0000,"publicationDate":"1980-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientia Sinica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In literature, the HBE has been displayed by application of the averaging method. In this paper, correlation analysis technique was used and the body-surface HBE was displayed in a special-purpose electronic computer. The correlation coefficients of the P-A, A-H, H-V intervals and the H-wave width of both methods are almost equivalent and one can be substituted by the other. Compared with the averaging method, the S/N ratio of the correlation method is greater and the residual noise is nearly absent. Furthermore, the effects of the integrating time T and delay time delta tau on the S/N ratio, the measuring resolution and the analytical time have been studied. Correlation analysis technique is a method based on the cybernetic and information theory. With this technique, by using correlation function, the dependence (auto-correlation function) of the value at one instant upon that of the other during the same random process, or the interdependence between sets of data from 2 random processes can be described. Up to the present, there has been no report on the activities of the ventricular conductive system with the S/N ratio smaller than 1, detected on the body surface by correlation analysis technique[1 - 3]. However, using this technique, the author successfully detected the body surface HBE with a special-purpose mini-computer in 1977.