Thoraco-abdominal bypass as a method of evaluating vascular grafts in the dog.

O Goeau-Brissonnière, R Guidoin, M Marois, B Boyce, J C Péchère, B Blais, H P Noël, C Gosselin
{"title":"Thoraco-abdominal bypass as a method of evaluating vascular grafts in the dog.","authors":"O Goeau-Brissonnière,&nbsp;R Guidoin,&nbsp;M Marois,&nbsp;B Boyce,&nbsp;J C Péchère,&nbsp;B Blais,&nbsp;H P Noël,&nbsp;C Gosselin","doi":"10.3109/10731198109119000","DOIUrl":null,"url":null,"abstract":"<p><p>Seven Vasculour d grafts, five Gore-Tex grafts and seven Solco-graft, 8 mm by 30 cm, implanted as thoraco-abdominal bypasses in dogs. Sixteen were retrieve at two months. Graft size was assessed angiographically in representative dogs of each group prior to sacrifice. Initial examination of the retrieved specimens revealed pannus extensions at both anastomoses on all graft types, and a variable midgraft appearance from smooth and glistening to partially thrombus coated. Histological assessment of graft segments revealed widely differing healing responses on the three graft types. Tissue attachment to both graft surfaces and varying degrees of tissue incorporation were observed in the Vasculour D and Gore-Tex prostheses. The Solco-graft specimens showed no evidence of tissue incorporation of the wall at two months. Tissue on the graft surfaces remains loosely attached and unincorporated. Pannus extensions were thickest on the Solco-graft. Variably thin fibrin is scattered over the luminal surface of the three graft types. Vascularization of the wall particularly the internal capsulae was noted in the Vasculour D grafts. Although biological responses in the dog are difficult to extrapolate to man, the types of comparison testing allowed by the use of the thoraco-abdominal by-pass procedure can provide valuable information of degree of dilation, relative tissue attachment, tissue incorporation into various types of prostheses and kidney infarcts study. The greatest value of the thoraco-abdominal by-pass lies in graft sizes and length without special regard for patency: assessment of graft size post-implantation and structural changes is then made possible.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"9 3","pages":"195-212"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198109119000","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198109119000","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Seven Vasculour d grafts, five Gore-Tex grafts and seven Solco-graft, 8 mm by 30 cm, implanted as thoraco-abdominal bypasses in dogs. Sixteen were retrieve at two months. Graft size was assessed angiographically in representative dogs of each group prior to sacrifice. Initial examination of the retrieved specimens revealed pannus extensions at both anastomoses on all graft types, and a variable midgraft appearance from smooth and glistening to partially thrombus coated. Histological assessment of graft segments revealed widely differing healing responses on the three graft types. Tissue attachment to both graft surfaces and varying degrees of tissue incorporation were observed in the Vasculour D and Gore-Tex prostheses. The Solco-graft specimens showed no evidence of tissue incorporation of the wall at two months. Tissue on the graft surfaces remains loosely attached and unincorporated. Pannus extensions were thickest on the Solco-graft. Variably thin fibrin is scattered over the luminal surface of the three graft types. Vascularization of the wall particularly the internal capsulae was noted in the Vasculour D grafts. Although biological responses in the dog are difficult to extrapolate to man, the types of comparison testing allowed by the use of the thoraco-abdominal by-pass procedure can provide valuable information of degree of dilation, relative tissue attachment, tissue incorporation into various types of prostheses and kidney infarcts study. The greatest value of the thoraco-abdominal by-pass lies in graft sizes and length without special regard for patency: assessment of graft size post-implantation and structural changes is then made possible.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
犬胸腹旁路移植术评价血管移植的方法。
7块血管移植片,5块Gore-Tex移植片和7块solco移植片,8 mm × 30 cm作为狗的胸腹旁路。其中16例在2个月时被取出。在牺牲前,对每组有代表性的狗进行血管造影评估移植物的大小。对所取标本的初步检查显示,在所有移植物类型的两个吻合口都有输卵管延伸,并且移植物的外观从光滑和闪光到部分血栓覆盖不等。移植物节段的组织学评估显示三种移植物类型的愈合反应差异很大。在血管D和Gore-Tex假体中观察到组织附着于移植物表面和不同程度的组织结合。两个月时,solco移植标本未见组织与壁合并的迹象。移植物表面的组织仍然松散地附着在一起。在Solco-graft上,Pannus延伸最厚。三种移植物的管腔表面分布着不同程度的薄纤维蛋白。血管壁的血管化,特别是内囊在血管D移植中被注意到。虽然狗的生物学反应很难推断到人身上,但使用胸腹旁路手术所允许的比较测试类型可以提供有价值的信息,包括扩张程度、相对组织附着、组织融入各种类型的假体和肾梗死研究。胸腹旁路的最大价值在于移植物的大小和长度,而无需特别考虑通畅性:然后可以评估移植物植入后的大小和结构变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo. Particulate aluminum oxide as a bone graft material. Abstracts. Fifth Southern Biomedical Engineering Conference. Shreveport, October 20-21, 1986. Custom-made vaginal balloons for strengthening circumvaginal musculature. Electrical conduction in bone in frequency range 0.4-1.3 GHz.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1