J R Cram, J Lloyd, T S Cahn
{"title":"The reliability of EMG muscle scanning.","authors":"J R Cram,&nbsp;J Lloyd,&nbsp;T S Cahn","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The reliability of a surface EMG scanning procedure was investigated for the right and left aspects of 10 muscle sites using a large clinical sample of 102 chronic pain patients. Two neutral postures (sitting/standing) were systematically studied on three occasions approximately one hour apart on the same day. The multivariate analysis of RMS microvolts indicated no significant effects for Age, Gender, Muscle site, Aspect or Period. The range of the Pearson correlations was 0.41 to 0.94 when all muscle sites, aspects, postures, and periods were considered. The median correlation was found to be 0.64. The pattern of reliability was seen to be slightly higher in the upper back while sitting, and slightly higher in the lower back while standing. The results indicate that with adequate attention to skin preparation, EMG sensors held in place by hand with a light pressure produce reliable results.</p>","PeriodicalId":77182,"journal":{"name":"International journal of psychosomatics : official publication of the International Psychosomatics Institute","volume":"41 1-4","pages":"41-5"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of psychosomatics : official publication of the International Psychosomatics Institute","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The reliability of a surface EMG scanning procedure was investigated for the right and left aspects of 10 muscle sites using a large clinical sample of 102 chronic pain patients. Two neutral postures (sitting/standing) were systematically studied on three occasions approximately one hour apart on the same day. The multivariate analysis of RMS microvolts indicated no significant effects for Age, Gender, Muscle site, Aspect or Period. The range of the Pearson correlations was 0.41 to 0.94 when all muscle sites, aspects, postures, and periods were considered. The median correlation was found to be 0.64. The pattern of reliability was seen to be slightly higher in the upper back while sitting, and slightly higher in the lower back while standing. The results indicate that with adequate attention to skin preparation, EMG sensors held in place by hand with a light pressure produce reliable results.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肌电图扫描的可靠性。
通过102例慢性疼痛患者的临床样本,研究了表面肌电扫描程序对10个肌肉部位的左右两侧的可靠性。两种中立姿势(坐/站)被系统地研究了三次,在同一天大约间隔一小时。RMS微电压的多变量分析显示,年龄、性别、肌肉部位、肌肉形态和周期对患者无显著影响。当考虑到所有肌肉部位、侧面、姿势和周期时,Pearson相关性的范围为0.41至0.94。中位相关系数为0.64。人们发现,坐着时,上背部的可靠性略高,站着时,下背部的可靠性略高。结果表明,在充分注意皮肤准备的情况下,用手在轻压下放置肌电图传感器可以产生可靠的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effects of electrode placement upon EEG biofeedback training: the monopolar-bipolar controversy. Anxiety and its control. Implanted transmitter in maxilla: real or imaginary? Psychotherapeutic implications of self-discoveries made in exploring psychologically-caused physical symptoms. Psychological factors in psychosomatic diseases: an outline of research results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1