[One lung ventilation in cases with unsuccessful double-lumen endobronchial intubation].

R K Cheng, H S Chung, P P Tan
{"title":"[One lung ventilation in cases with unsuccessful double-lumen endobronchial intubation].","authors":"R K Cheng,&nbsp;H S Chung,&nbsp;P P Tan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Three cases of thoracotomy with unsuccessful double-lumen endobronchial intubation were reported. Two were first intubated with an endotracheal tube. In the first patient a Fogarty catheter was inserted alongside the endotracheal tube into the right main bronchus to act as a bronchial blocker. The second patient employed a tracheal tube exchanger to change the endotracheal tube into an Univent tube for one lung ventilation. Nasal fiberoptic intubation was performed in the third case and a Fogarty catheter was passed through the lumen of the endotracheal tube into the left main bronchus as the bronchial blocker. All reported cases were operated with one lung ventilation successfully without the use of a double-lumen endobronchial tube.</p>","PeriodicalId":77247,"journal":{"name":"Ma zui xue za zhi = Anaesthesiologica Sinica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1993-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ma zui xue za zhi = Anaesthesiologica Sinica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Three cases of thoracotomy with unsuccessful double-lumen endobronchial intubation were reported. Two were first intubated with an endotracheal tube. In the first patient a Fogarty catheter was inserted alongside the endotracheal tube into the right main bronchus to act as a bronchial blocker. The second patient employed a tracheal tube exchanger to change the endotracheal tube into an Univent tube for one lung ventilation. Nasal fiberoptic intubation was performed in the third case and a Fogarty catheter was passed through the lumen of the endotracheal tube into the left main bronchus as the bronchial blocker. All reported cases were operated with one lung ventilation successfully without the use of a double-lumen endobronchial tube.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[双腔支气管内插管不成功的单肺通气]。
本文报告3例开胸双腔支气管内插管不成功的病例。其中两人首先用气管内插管。在第一位患者中,福格蒂导管与气管内管一起插入右主支气管,作为支气管阻滞剂。第二例患者使用气管管交换器将气管内管改为Univent管进行单肺通气。第三例患者行鼻纤维插管,Fogarty导管经气管内管腔进入左主支气管作为支气管阻滞剂。所有病例均成功进行单肺通气,未使用双腔支气管内管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prolonged fasting in pediatric outpatients does not cause hypoglycemia. Continuous succinylcholine infusion and phase II block in short surgical procedures. [Pheochromocytoma]. [Anesthetic management of intraoperatively diagnosed pheochromocytoma--a case report]. [Postoperative hypoglycemia after pheochromocytoma resection].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1