Simple decomposition procedure for determination of selenium in whole blood, serum and urine by hydride generation atomic absorption spectroscopy.

B Tiran, A Tiran, E Rossipal, O Lorenz
{"title":"Simple decomposition procedure for determination of selenium in whole blood, serum and urine by hydride generation atomic absorption spectroscopy.","authors":"B Tiran,&nbsp;A Tiran,&nbsp;E Rossipal,&nbsp;O Lorenz","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A digestion procedure for selenium determination by hydride generation atomic absorption spectroscopy (AAS) in whole blood, serum and urine is described, it employs sulfuric acid, hydrogen peroxide and vanadium (V) sulfuric acid reagent solution. The method is rapid, uses no explosive reagents and can be performed at a constant temperature of 100 degrees C. Therefore, it is easily applicable in a routine clinical laboratory for a large amount of samples. The coefficient of intra-assay variation was 4.3-5.6%, the coefficient for inter-assay variation was 5-5.9% in the medium and high concentration range, and 5.8-8.6% in the low range. In analyzing several commercial reference materials our results showed good agreement with the target values. Analytical recovery by addition of sodium selenite and seleno-DL-methionine to samples ranged between 97 and 104%. The correlation between the described digestion procedure and the nitric, sulfuric and perchloric acid digestion procedure recommended by the International Union of Pure and Applied Chemistry showed good agreement for whole blood, serum and for urine. We determined selenium in serum (n = 58) and whole blood (n = 50) in a collective of healthy children from 1 to 5 years living in Styria, Austria. The low values in serum (35 +/- 11 micrograms/L) and whole blood (42 +/- 6 micrograms/L) at one year of life increased significantly to 48 +/- 13 mu/L (p = 0.033) and 55 +/- 6 micrograms/L (p = 0.004) at three years of life in serum and whole blood, respectively. The selenium concentration showed no further increase up to five years of age.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":77233,"journal":{"name":"Journal of trace elements and electrolytes in health and disease","volume":"7 4","pages":"211-6"},"PeriodicalIF":0.0000,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of trace elements and electrolytes in health and disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A digestion procedure for selenium determination by hydride generation atomic absorption spectroscopy (AAS) in whole blood, serum and urine is described, it employs sulfuric acid, hydrogen peroxide and vanadium (V) sulfuric acid reagent solution. The method is rapid, uses no explosive reagents and can be performed at a constant temperature of 100 degrees C. Therefore, it is easily applicable in a routine clinical laboratory for a large amount of samples. The coefficient of intra-assay variation was 4.3-5.6%, the coefficient for inter-assay variation was 5-5.9% in the medium and high concentration range, and 5.8-8.6% in the low range. In analyzing several commercial reference materials our results showed good agreement with the target values. Analytical recovery by addition of sodium selenite and seleno-DL-methionine to samples ranged between 97 and 104%. The correlation between the described digestion procedure and the nitric, sulfuric and perchloric acid digestion procedure recommended by the International Union of Pure and Applied Chemistry showed good agreement for whole blood, serum and for urine. We determined selenium in serum (n = 58) and whole blood (n = 50) in a collective of healthy children from 1 to 5 years living in Styria, Austria. The low values in serum (35 +/- 11 micrograms/L) and whole blood (42 +/- 6 micrograms/L) at one year of life increased significantly to 48 +/- 13 mu/L (p = 0.033) and 55 +/- 6 micrograms/L (p = 0.004) at three years of life in serum and whole blood, respectively. The selenium concentration showed no further increase up to five years of age.(ABSTRACT TRUNCATED AT 250 WORDS)

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氢化物发生原子吸收光谱法测定全血、血清和尿中硒的简单分解方法。
采用硫酸、过氧化氢和钒(V)硫酸试剂溶液,建立了氢化物发生原子吸收光谱(AAS)法测定全血、血清和尿液中硒的消解方法。该方法快速,不使用爆炸性试剂,可在100℃恒温下进行,因此易于适用于常规临床实验室中大量样品的检测。测定结果表明,中、高浓度组内变异系数为4.3 ~ 5.6%,中、高浓度组间变异系数为5 ~ 5.9%,低浓度组间变异系数为5.8 ~ 8.6%。通过对几种商业标准物质的分析,结果与目标值吻合较好。添加亚硒酸钠和硒- dl -蛋氨酸的分析回收率在97 ~ 104%之间。所描述的消化程序与国际纯粹与应用化学联合会推荐的硝酸、硫酸和高氯酸消化程序之间的相关性表明,全血、血清和尿液的消化程序具有良好的一致性。我们对生活在奥地利施蒂里亚的1 ~ 5岁健康儿童进行血清(n = 58)和全血(n = 50)硒测定。1岁时血清低值(35 +/- 11 μ g /L)和全血低值(42 +/- 6 μ g /L)显著升高至48 +/- 13 μ g /L (p = 0.033), 3岁时血清和全血低值分别为55 +/- 6 μ g /L (p = 0.004)。直至5岁,硒浓度没有进一步增加。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Review of Publications Review of publications. Factors influencing blood selenium concentration values: a literature review. Trace element alterations in rat tissues induced by the hepatotoxic agent CCl4. The mineral and trace element composition in French food items and intake levels in France.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1