Systolic ventricular function in acute hypothyroidism: a study using Doppler echocardiography.

G Grossmann, F S Keck, S Wieshammer, V Göller, A Schmidt, V Hombach
{"title":"Systolic ventricular function in acute hypothyroidism: a study using Doppler echocardiography.","authors":"G Grossmann,&nbsp;F S Keck,&nbsp;S Wieshammer,&nbsp;V Göller,&nbsp;A Schmidt,&nbsp;V Hombach","doi":"10.1055/s-0029-1211271","DOIUrl":null,"url":null,"abstract":"<p><p>The influence of thyroid state on left ventricular systolic function was studied in 11 patients (5 men, 6 women, aged 20-55 years) without cardiac disease, who had undergone total thyroidectomy and radioiodine treatment for thyroid cancer before. Pulsed-wave Doppler echocardiographic measuring of aortic blood flow and two-dimensional/time-motion (2D/M-mode) echocardiography were performed on two occasions once while the patients were mildly hyperthyroid on thyroxine replacement therapy and once when they were hypothyroid. During hypothyroidism left ventricular end-diastolic diameter decreased from 48 +/- 5 mm to 46 +/- 5 mm (p < 0.05). The diameter of the aortic ring, the left ventricular end-systolic diameter, the thickness of the interventricular septum and posterior wall, and fractional shortening did not differ significantly between the two studies. The following parameter of aortic blood flow changed significantly when passing from the hyperthyroid to the hypothyroid state: peak velocity (0.86 +/- 0.15 m/s versus 0.72 +/- 0.15 m/s, p < 0.01); mean velocity (0.49 +/- 0.08 m/s versus 0.44 +/- 0.08 m/s, p < 0.01); time- velocity integral (14.1 +/- 3.0 cm versus 12.3 +/- 3.1 cm, p < 0.05); stroke volume (43.0 +/- 9.7 ml versus 35.2 +/- 8.2 ml, p < 0.05); and preejection period (124 +/- 23 ms versus 147 +/- 21 ms, p < 0.01). Peak acceleration, mean acceleration, acceleration time and left ventricular ejection time did not change when the thyroid state was altered. It is concluded that left ventricular contractile function was not affected by acute hypothyroidism.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":12104,"journal":{"name":"Experimental and clinical endocrinology","volume":"102 2","pages":"104-10"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0029-1211271","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental and clinical endocrinology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0029-1211271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

The influence of thyroid state on left ventricular systolic function was studied in 11 patients (5 men, 6 women, aged 20-55 years) without cardiac disease, who had undergone total thyroidectomy and radioiodine treatment for thyroid cancer before. Pulsed-wave Doppler echocardiographic measuring of aortic blood flow and two-dimensional/time-motion (2D/M-mode) echocardiography were performed on two occasions once while the patients were mildly hyperthyroid on thyroxine replacement therapy and once when they were hypothyroid. During hypothyroidism left ventricular end-diastolic diameter decreased from 48 +/- 5 mm to 46 +/- 5 mm (p < 0.05). The diameter of the aortic ring, the left ventricular end-systolic diameter, the thickness of the interventricular septum and posterior wall, and fractional shortening did not differ significantly between the two studies. The following parameter of aortic blood flow changed significantly when passing from the hyperthyroid to the hypothyroid state: peak velocity (0.86 +/- 0.15 m/s versus 0.72 +/- 0.15 m/s, p < 0.01); mean velocity (0.49 +/- 0.08 m/s versus 0.44 +/- 0.08 m/s, p < 0.01); time- velocity integral (14.1 +/- 3.0 cm versus 12.3 +/- 3.1 cm, p < 0.05); stroke volume (43.0 +/- 9.7 ml versus 35.2 +/- 8.2 ml, p < 0.05); and preejection period (124 +/- 23 ms versus 147 +/- 21 ms, p < 0.01). Peak acceleration, mean acceleration, acceleration time and left ventricular ejection time did not change when the thyroid state was altered. It is concluded that left ventricular contractile function was not affected by acute hypothyroidism.(ABSTRACT TRUNCATED AT 250 WORDS)

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
急性甲状腺功能减退症的收缩心室功能:多普勒超声心动图研究。
本文研究了甲状腺状态对左心室收缩功能的影响,其中11例(男5例,女6例,年龄20 ~ 55岁)无心脏疾病,既往行甲状腺全切除术和放射性碘治疗甲状腺癌。脉冲波多普勒超声心动图测量主动脉血流和二维/时间运动(2D/ m模式)超声心动图两次,一次是在轻度甲状腺功能亢进患者接受甲状腺素替代治疗时,一次是在甲状腺功能减退时。甲状腺功能减退时左室舒张末期内径由48 +/- 5 mm降至46 +/- 5 mm (p < 0.05)。主动脉环直径、左心室收缩末期直径、室间隔和后壁厚度以及分数缩短在两项研究中没有显著差异。由甲亢状态转为甲亢状态时,主动脉血流参数变化显著:峰值流速(0.86 +/- 0.15 m/s vs 0.72 +/- 0.15 m/s, p < 0.01);平均速度(0.49 +/- 0.08 m/s vs 0.44 +/- 0.08 m/s, p < 0.01);时间-速度积分(14.1 +/- 3.0 cm vs 12.3 +/- 3.1 cm, p < 0.05);卒中容积(43.0 +/- 9.7 ml vs 35.2 +/- 8.2 ml, p < 0.05);射血前期(124 +/- 23 ms vs 147 +/- 21 ms, p < 0.01)。甲状腺状态改变后,峰值加速度、平均加速度、加速时间和左心室射血时间均无明显变化。结论急性甲状腺功能减退对左室收缩功能无影响。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In vivo-effect of intraadrenal nicotine and substance P application on rat adrenal medullary catecholamine secretion. Intracellular sex hormone-binding globulin (SHBG) in normal and neoplastic breast tissue--an additional marker for hormone dependency? Immune intervention in type I diabetes mellitus--current clinical and experimental approaches. Growth hormone therapy in adults: rationales, results, and perspectives. Endocrine characterization of the new dopamine autoreceptor agonist roxindole.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1