[Experience with electronic breath test devices in the realm of forensic expert assessment].

Blutalkohol Pub Date : 1993-07-01
N Bilzer, O Grüner
{"title":"[Experience with electronic breath test devices in the realm of forensic expert assessment].","authors":"N Bilzer,&nbsp;O Grüner","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>From january 1990 till may 1992 4,949 cases of BEC-values were compared with BAC-values. A relatively good correspondence turned out between the BEC- and BAC-values in most of the cases, nevertheless in some cases extremely high deviations showed up. Therefore the BEC-values cannot be taken for a sure evidence using the BEC-devices. A reliable inference from BEC-values to the unability of driving or criminal responsibility is not possible at the moment, if the administration of justice wants to keep to the principle \"in dubio pro reo\" further on.</p>","PeriodicalId":77045,"journal":{"name":"Blutalkohol","volume":"30 4","pages":"225-31"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blutalkohol","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

From january 1990 till may 1992 4,949 cases of BEC-values were compared with BAC-values. A relatively good correspondence turned out between the BEC- and BAC-values in most of the cases, nevertheless in some cases extremely high deviations showed up. Therefore the BEC-values cannot be taken for a sure evidence using the BEC-devices. A reliable inference from BEC-values to the unability of driving or criminal responsibility is not possible at the moment, if the administration of justice wants to keep to the principle "in dubio pro reo" further on.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[在法医专家评估领域使用电子呼气测试设备的经验]。
从1990年1月至1992年5月,对4949例bc值与bac值进行了比较。在大多数情况下,BEC-值和bac -值之间的对应关系相对较好,但在某些情况下出现了极高的偏差。因此,bec值不能作为使用bec装置的确切证据。如果司法部门想要继续坚持“不确定是否会再犯”的原则,那么目前还不可能从bec价值观中得出关于无驾驶能力或刑事责任的可靠推论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[The German promille law--overview and guideline for legal traffic applications]. [Alcohol and energy drink--can combined consumption of both beverages modify automobile driving fitness?]. [The accuracy of blood alcohol determination with head-space GC, ADH and REA ethanol assay for the AXSYM system--a comparison of the methods]. [Separation of therapy and diagnosis on the one hand--need for interprofessional cooperation on the other hand. Also a critical comment to the contribution of Pund and Kajan]. [Lowering the promille limit?].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1