Left ventricular end-diastolic dimensions measured at the P wave and Q wave during a randomized, double-blind one-year follow-up study comparing the effect of atenolol vs. hydrochlorothiazide + amiloride on blood pressure in men with mild to moderate hypertension.
{"title":"Left ventricular end-diastolic dimensions measured at the P wave and Q wave during a randomized, double-blind one-year follow-up study comparing the effect of atenolol vs. hydrochlorothiazide + amiloride on blood pressure in men with mild to moderate hypertension.","authors":"J E Otterstad, G Froeland, J Erikssen","doi":"10.3109/00365519309088402","DOIUrl":null,"url":null,"abstract":"<p><p>Echocardiographic measurement of left ventricular (LV) end-diastolic dimensions and mass (M) were made at baseline, at 3 and 12 months of a randomized trial comparing atenolol 50/100 mg od. and hydrochlorothiazide 25/50 mg+amiloride 5 mg od. (co-amiloride) in 100 men with mild to moderate hypertension. Data from 48 subjects controlled adequately on drug monotherapy and completing 12 months treatment are reported (31 randomized to atenolol and 17 to co-amiloride). Left ventricular mass was measured with the Penn convention at the R and P wave respectively. A significant reduction of LVM was noted after one year in both groups (p < 0.05) when measured at the R, but not at the P wave. Measurements according to American Society of Echocardiography (ASE method) at the Q wave revealed a significant reduction of LV wall thickness (p < 0.01) and an increase of LV internal diameter (p < 0.01) with atenolol. In the co-amiloride group non-significant reductions of LV dimensions were observed. Principally similar changes were observed with measurements at the P wave (National Institute of Heart method) in both groups, but LV wall thickness was greater and LV internal diameter smaller than at the Q wave. With similar effect on LVM, the mechanisms in reducing LVM were different between the two drugs. Left ventricular dimensions differed when assessed with the two methods applied, stressing the need for careful standardization in relation to the cardiac cycle in serial echocardiographic measurements.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":"53 2","pages":"155-62"},"PeriodicalIF":1.4000,"publicationDate":"1993-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00365519309088402","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3109/00365519309088402","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 1
Abstract
Echocardiographic measurement of left ventricular (LV) end-diastolic dimensions and mass (M) were made at baseline, at 3 and 12 months of a randomized trial comparing atenolol 50/100 mg od. and hydrochlorothiazide 25/50 mg+amiloride 5 mg od. (co-amiloride) in 100 men with mild to moderate hypertension. Data from 48 subjects controlled adequately on drug monotherapy and completing 12 months treatment are reported (31 randomized to atenolol and 17 to co-amiloride). Left ventricular mass was measured with the Penn convention at the R and P wave respectively. A significant reduction of LVM was noted after one year in both groups (p < 0.05) when measured at the R, but not at the P wave. Measurements according to American Society of Echocardiography (ASE method) at the Q wave revealed a significant reduction of LV wall thickness (p < 0.01) and an increase of LV internal diameter (p < 0.01) with atenolol. In the co-amiloride group non-significant reductions of LV dimensions were observed. Principally similar changes were observed with measurements at the P wave (National Institute of Heart method) in both groups, but LV wall thickness was greater and LV internal diameter smaller than at the Q wave. With similar effect on LVM, the mechanisms in reducing LVM were different between the two drugs. Left ventricular dimensions differed when assessed with the two methods applied, stressing the need for careful standardization in relation to the cardiac cycle in serial echocardiographic measurements.
期刊介绍:
The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry.
The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.