Relationship between viscosity and determined injection pressure in angiography catheters for common roentgen contrast media.

K Dyvik, K Dyrstad, A Tronstad
{"title":"Relationship between viscosity and determined injection pressure in angiography catheters for common roentgen contrast media.","authors":"K Dyvik,&nbsp;K Dyrstad,&nbsp;A Tronstad","doi":"10.1177/0284185195036s39906","DOIUrl":null,"url":null,"abstract":"<p><p>The viscosity of 8 commercially available contrast media (CM) at 2 or 3 concentrations were measured as a function of concentration and temperature, using a rotational viscosmeter. Further on, by use of an automated injector, injection pressures were measured for 3 of the CM at various concentrations, temperatures, catheter lengths, catheter diameters and flow rates. The experiments were performed as fractional factorial designs. The correlation between the injection pressure and the viscosity was found to be log-linear, and an empiric equation was established for this relationship. The relative reduction of viscosity - and therby injection pressure - with increasing injection temperature, was largest for the most concentrated CM. Iodixanol and iotrolan, the 2 nonionic dimers investigated, demonstrated an increased viscosity compared to the nonionic monomers at equal concentrations. However, all CM investigated could be used with an acceptable injection pressure either by relatively small changes in catheter conditions or by adjustment of injection temperature closer to body temperature.</p>","PeriodicalId":7159,"journal":{"name":"Acta radiologica. Supplementum","volume":"399 ","pages":"43-9"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/0284185195036s39906","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/0284185195036s39906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

The viscosity of 8 commercially available contrast media (CM) at 2 or 3 concentrations were measured as a function of concentration and temperature, using a rotational viscosmeter. Further on, by use of an automated injector, injection pressures were measured for 3 of the CM at various concentrations, temperatures, catheter lengths, catheter diameters and flow rates. The experiments were performed as fractional factorial designs. The correlation between the injection pressure and the viscosity was found to be log-linear, and an empiric equation was established for this relationship. The relative reduction of viscosity - and therby injection pressure - with increasing injection temperature, was largest for the most concentrated CM. Iodixanol and iotrolan, the 2 nonionic dimers investigated, demonstrated an increased viscosity compared to the nonionic monomers at equal concentrations. However, all CM investigated could be used with an acceptable injection pressure either by relatively small changes in catheter conditions or by adjustment of injection temperature closer to body temperature.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
常用造影剂血管造影剂导管粘度与注射压力的关系。
使用旋转粘度计测量了8种市售造影剂(CM)在2或3种浓度下的粘度,作为浓度和温度的函数。此外,通过使用自动注射器,测量了3个CM在不同浓度、温度、导管长度、导管直径和流速下的注射压力。实验采用分数因子设计。发现了注入压力与粘度之间的对数线性关系,并建立了该关系的经验方程。对于浓度最高的CM,随着注射温度的升高,粘度和注射压力的相对降低幅度最大。所研究的两种非离子二聚体碘二醇和碘曲兰在相同浓度下比非离子单体具有更高的粘度。然而,所有CM都可以在一个可接受的注射压力下使用,要么通过相对较小的导管条件变化,要么通过调整注射温度更接近体温。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Contrast-enhanced magnetic resonance angiography: development and optimization of techniques for paramagnetic and hyperpolarized contrast media. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery. XI International Workshop in Magnetic Resonance Angiography: new aspects on visualisation of macro- and microcirculation. Lund, Sweden, September 22-25, 1999. Abstracts. Ultrasonography as adjunct to mammography in the evaluation of breast tumors. The postoperative lumbar spine. A radiological investigation of the lumbar spine after discectomy using MR imaging and CT.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1