{"title":"Iobitridol 300 compared to iopromide 300--a double-blind randomized phase-III study of clinical tolerance in total body CT.","authors":"H M Hoogewoud, B Woessmer","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>PURPOSE, MATERIAL AND METHODS: The clinical safety of iobitriodol 300 mg I/ml and iopromide 300 mg I/ml were compared in a randomized double blind phase-III study conducted on 60 patients undergoing abdominal CT for a variety of indications. Each examination was rated as diagnostic or nondiagnostic and the image quality was noted. Nature, onset, intensity as well as outcome of each adverse reaction were recorded.</p><p><strong>Results: </strong>There was no significant difference in imaging quality and side effects between the contrast media. In this study, both iobitridol and iopromide provided excellent image quality and a low rate of side effects.</p><p><strong>Conclusion: </strong>Iobitridol is a safe and effective nonionic contrast agent for contrast-enhanced body CT.</p>","PeriodicalId":7159,"journal":{"name":"Acta radiologica. Supplementum","volume":"400 ","pages":"62-4"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Unlabelled: PURPOSE, MATERIAL AND METHODS: The clinical safety of iobitriodol 300 mg I/ml and iopromide 300 mg I/ml were compared in a randomized double blind phase-III study conducted on 60 patients undergoing abdominal CT for a variety of indications. Each examination was rated as diagnostic or nondiagnostic and the image quality was noted. Nature, onset, intensity as well as outcome of each adverse reaction were recorded.
Results: There was no significant difference in imaging quality and side effects between the contrast media. In this study, both iobitridol and iopromide provided excellent image quality and a low rate of side effects.
Conclusion: Iobitridol is a safe and effective nonionic contrast agent for contrast-enhanced body CT.