Anaesthetic drugs and bacterial contamination.

L Magee, L Godsiff, I Matthews, M Farrington, G R Park
{"title":"Anaesthetic drugs and bacterial contamination.","authors":"L Magee,&nbsp;L Godsiff,&nbsp;I Matthews,&nbsp;M Farrington,&nbsp;G R Park","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We investigated the bacterial contamination of commonly used intravenous anaesthetic agents. Ten trainee anaesthetists drew up four syringes each of propofol, midazolam, thiopentone, 0.9% saline and a culture medium control using their normal practice. A set of syringes was cultured at the time of drawing up and at 2, 4 and 8 h afterwards. No anaesthetist washed his or her hands before drawing up the drugs. Six anaesthetists capped the syringes using sheathed needles. Eight syringes were contaminated with bacteria. Coagulase-negative staphylococci were isolated from six syringes (four sheathed and two unsheathed) and an Acinetobacter sp. from two syringes (one sheathed and one unsheathed). No bacteria were cultured from the midazolam syringes. However, two syringes from each of the other solutions were contaminated. This implies that one syringe was contaminated when it was drawn up, at 2 h a further two had detectable contamination, two more were contaminated at 4 h and three more at 8 h. We cannot recommend drawing up drugs at the start of a list for use later in the day. They should be used immediately after drawing up. Basic hand washing before drawing up drugs may reduce contamination.</p>","PeriodicalId":11873,"journal":{"name":"European journal of anaesthesiology. Supplement","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of anaesthesiology. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We investigated the bacterial contamination of commonly used intravenous anaesthetic agents. Ten trainee anaesthetists drew up four syringes each of propofol, midazolam, thiopentone, 0.9% saline and a culture medium control using their normal practice. A set of syringes was cultured at the time of drawing up and at 2, 4 and 8 h afterwards. No anaesthetist washed his or her hands before drawing up the drugs. Six anaesthetists capped the syringes using sheathed needles. Eight syringes were contaminated with bacteria. Coagulase-negative staphylococci were isolated from six syringes (four sheathed and two unsheathed) and an Acinetobacter sp. from two syringes (one sheathed and one unsheathed). No bacteria were cultured from the midazolam syringes. However, two syringes from each of the other solutions were contaminated. This implies that one syringe was contaminated when it was drawn up, at 2 h a further two had detectable contamination, two more were contaminated at 4 h and three more at 8 h. We cannot recommend drawing up drugs at the start of a list for use later in the day. They should be used immediately after drawing up. Basic hand washing before drawing up drugs may reduce contamination.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
麻醉药物和细菌污染。
我们调查了常用静脉麻醉药的细菌污染情况。10名实习麻醉师按照他们的常规抽取了四支注射器,分别是异丙酚、咪达唑仑、硫喷妥酮、0.9%生理盐水和培养基对照。在拔管时和拔管后2、4、8 h分别培养一组注射器。麻醉师在抽药前没有洗手。六名麻醉师用带套的针头给注射器盖上盖子。8支注射器被细菌污染。从6支注射器(4支套套和2支未套套)中分离到凝固酶阴性葡萄球菌,从2支注射器(1支套套和1支未套套)中分离到不动杆菌属。咪达唑仑注射器未培养细菌。然而,其他溶液的两个注射器都被污染了。这意味着一个注射器在起草时被污染了,在2小时,另外两个有可检测到的污染,另外两个在4小时被污染,另外三个在8小时被污染。我们不建议在开始时起草药物清单以供当天晚些时候使用。起草后应立即使用。提药前基本洗手可减少污染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Near-infrared spectroscopy (NIRS) in a piglet model: readings are influenced by the colour of the cover Clinical sedation and bispectral index in burn children receiving gamma-hydroxybutyrate. Acute Normovolemic hemodilution during CABG induces diastolic dysfunction: A perioperative transesophageal echocardiographic study EuroNeuro 2010. Abstracts of the 6th EuroNeuro Congress. Porto, Portugal. February 4-6, 2010. 5th EuroNeuro 2008. Maastricht, The Netherlands. January 16-19, 2008. Abstracts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1