{"title":"A new reliable chemiluminescence immunoassay (CLIA) for prostaglandin E2 using enhanced luminol as substrate","authors":"W. Neupert, R. Oelkers, K. Brune, G. Geisslinger","doi":"10.1016/S0090-6980(96)00103-7","DOIUrl":null,"url":null,"abstract":"<div><p>A sensitive and reliable chemiluminescence immunoassay suitable for the quantitative determination of prostaglandin E<sub>2</sub> (PGE<sub>2</sub>) has been developed using 96 well microtiter plates (MTP). The assay is based on a competitive reaction between a highly specific monoclonal anti-PGE<sub>2</sub> antibody (mouse), free antigen and solid phase bound antigen. The MTP was first coated with a bovine serum albumin (BSA)-PGE<sub>2</sub> conjugate. Then, after preincubating, the anti-PGE<sub>2</sub> antibody (Ab) and the analyte were added. The remaining amount of free antibody was captured by the solid phase bound BSA-PGE<sub>2</sub> conjugate. The monoclonal antibody captured on the MTP was determined using biotinylated antimouse-Ab and a complex of avidin and biotin-labelled horseradish peroxidase (HRP). Substrate for HRP was the cyclic diacyl hydrazide compound luminol, enhanced by p-iodophenol. Photons emitted during the reaction were measured using a photomultiplier tube. The assay has been validated with assay buffer and human plasma over a concentration range of 10–50,000 pglml. The lower limit of quantification is 100 pglml (2 pglwell) and 150 pglml (3 pglwell) for buffer and plasma, respectively. The intea-day coefficients of variation (CV) for the range of 100–50,000 pglml are 3.2–8.9% (buffer) and 4.2–17.7% (plasma) and inter-day CV are 2.9–19.8% (buffer) and 3.6–21.2% (plasma). The method can be used for quantification of PGE2 in biological fluids like plasma and suction blister fluid.</p></div>","PeriodicalId":20653,"journal":{"name":"Prostaglandins","volume":"52 5","pages":"Pages 385-401"},"PeriodicalIF":0.0000,"publicationDate":"1996-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0090-6980(96)00103-7","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prostaglandins","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0090698096001037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
A sensitive and reliable chemiluminescence immunoassay suitable for the quantitative determination of prostaglandin E2 (PGE2) has been developed using 96 well microtiter plates (MTP). The assay is based on a competitive reaction between a highly specific monoclonal anti-PGE2 antibody (mouse), free antigen and solid phase bound antigen. The MTP was first coated with a bovine serum albumin (BSA)-PGE2 conjugate. Then, after preincubating, the anti-PGE2 antibody (Ab) and the analyte were added. The remaining amount of free antibody was captured by the solid phase bound BSA-PGE2 conjugate. The monoclonal antibody captured on the MTP was determined using biotinylated antimouse-Ab and a complex of avidin and biotin-labelled horseradish peroxidase (HRP). Substrate for HRP was the cyclic diacyl hydrazide compound luminol, enhanced by p-iodophenol. Photons emitted during the reaction were measured using a photomultiplier tube. The assay has been validated with assay buffer and human plasma over a concentration range of 10–50,000 pglml. The lower limit of quantification is 100 pglml (2 pglwell) and 150 pglml (3 pglwell) for buffer and plasma, respectively. The intea-day coefficients of variation (CV) for the range of 100–50,000 pglml are 3.2–8.9% (buffer) and 4.2–17.7% (plasma) and inter-day CV are 2.9–19.8% (buffer) and 3.6–21.2% (plasma). The method can be used for quantification of PGE2 in biological fluids like plasma and suction blister fluid.