{"title":"[Indications and use of \"AO pinless fixateurs\". A preliminary report].","authors":"G Schippinger,&nbsp;F J Seibert,&nbsp;G Peicha,&nbsp;H P Hofer","doi":"10.1007/BF02641223","DOIUrl":null,"url":null,"abstract":"<p><p>Improvements in techniques for the management of open tibial fractures with the external fixator have made a great impact on the final results in recent years. More recently this system has been discussed controversially. The longer treatment takes, the more likely it is that complications will occur when relying solely on the conventional external fixator. The new pinless fixator for the tibia was designed to overcome these problems. Early conversion to a more stable implant is one of the primary goals of this system. In this article the pros and cons are presented in detail and the limitation of this device explained. Moreover first clinical experiences are summarized and possible additional indications highlighted.</p>","PeriodicalId":29789,"journal":{"name":"Unfallchirurgie","volume":"22 5","pages":"216-22"},"PeriodicalIF":0.6000,"publicationDate":"1996-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02641223","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Unfallchirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02641223","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 2

Abstract

Improvements in techniques for the management of open tibial fractures with the external fixator have made a great impact on the final results in recent years. More recently this system has been discussed controversially. The longer treatment takes, the more likely it is that complications will occur when relying solely on the conventional external fixator. The new pinless fixator for the tibia was designed to overcome these problems. Early conversion to a more stable implant is one of the primary goals of this system. In this article the pros and cons are presented in detail and the limitation of this device explained. Moreover first clinical experiences are summarized and possible additional indications highlighted.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
“AO无针固定器”的适应症和使用方法。初步报告]。
近年来,外固定架治疗开放性胫骨骨折的技术进步对最终结果产生了很大的影响。最近,人们对这一制度进行了有争议的讨论。治疗时间越长,单纯依靠常规外固定架时发生并发症的可能性越大。新的无针胫骨固定架就是为了克服这些问题而设计的。该系统的主要目标之一是尽早转换为更稳定的植入物。在本文中,详细介绍了该设备的优缺点,并解释了该设备的局限性。此外,总结了首次临床经验,并强调了可能的附加适应症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
25.00%
发文量
0
期刊最新文献
Wandel in der Behandlung der Patellafrakturen [American football injuries in the German Federal League: risk of injuries and pattern of injuries]. [Attempted suicide--a challenge for the trauma surgeon?]. [Self-mutilation as insurance fraud]. [Bilateral pertrochanteric spontaneous fracture in chronic alcoholism and liver cirrhosis. A case report].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1