Comparative field evaluation of HIV rapid diagnostic assays using serum, urine, and oral mucosal transudate specimens

David R. Tribble , Guénaël R. Rodier , Magdy D. Saad , Gérard Binson , Fabrice Marrot , Said Salah , Chakib Omar , Ray R. Arthur
{"title":"Comparative field evaluation of HIV rapid diagnostic assays using serum, urine, and oral mucosal transudate specimens","authors":"David R. Tribble ,&nbsp;Guénaël R. Rodier ,&nbsp;Magdy D. Saad ,&nbsp;Gérard Binson ,&nbsp;Fabrice Marrot ,&nbsp;Said Salah ,&nbsp;Chakib Omar ,&nbsp;Ray R. Arthur","doi":"10.1016/S0928-0197(96)00261-9","DOIUrl":null,"url":null,"abstract":"<div><p><strong>Background:</strong> Comparative field utility of selected HIV-1 assays using homologous collections of serum, urine and oral mucosal transudate (OMT) was determined in adult populations from a tuberculosis hospital and STD clinic in Djibouti, East Africa.</p><p><strong>Study design:</strong> Enzyme immunoassay with confirmatory Western blot was performed on all serum specimens for comparison with rapid, instrument-free assays (SUDS HIV-1, Murex; TestPack Abbott; and COMBAIDS HIV 1 + 2, SPAN Diagnostics) using various specimen sources. Delayed (48 h post-collection) testing was also performed on urine. Sensitivity and specificity for the rapid assays, in descending order, were as follows: serum SUDS HIV-1 assay (100%, 98.3%), serum COMBAIDS assay (98.4%, 99.6%), and OMT SUDS HIV-1 assay (98.4%, 94.5%).</p><p><strong>Results:</strong> The OMT EIA optical density cutoff value was modified resulting in an improved specificity from 89.1 to 99.6%; however, sensitivity decreased from 100 to 98.5%. Urine EIA and rapid assays demonstrated unacceptable test performance for use as a screening test.</p></div>","PeriodicalId":79479,"journal":{"name":"Clinical and diagnostic virology","volume":"7 3","pages":"Pages 127-132"},"PeriodicalIF":0.0000,"publicationDate":"1997-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0928-0197(96)00261-9","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and diagnostic virology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0928019796002619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Background: Comparative field utility of selected HIV-1 assays using homologous collections of serum, urine and oral mucosal transudate (OMT) was determined in adult populations from a tuberculosis hospital and STD clinic in Djibouti, East Africa.

Study design: Enzyme immunoassay with confirmatory Western blot was performed on all serum specimens for comparison with rapid, instrument-free assays (SUDS HIV-1, Murex; TestPack Abbott; and COMBAIDS HIV 1 + 2, SPAN Diagnostics) using various specimen sources. Delayed (48 h post-collection) testing was also performed on urine. Sensitivity and specificity for the rapid assays, in descending order, were as follows: serum SUDS HIV-1 assay (100%, 98.3%), serum COMBAIDS assay (98.4%, 99.6%), and OMT SUDS HIV-1 assay (98.4%, 94.5%).

Results: The OMT EIA optical density cutoff value was modified resulting in an improved specificity from 89.1 to 99.6%; however, sensitivity decreased from 100 to 98.5%. Urine EIA and rapid assays demonstrated unacceptable test performance for use as a screening test.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用血清、尿液和口腔粘膜渗出标本进行HIV快速诊断试验的现场比较评价
背景:在东非吉布提的一家结核病医院和性病诊所的成年人群中,使用同源收集的血清、尿液和口腔粘膜漏出物(OMT)对选定的HIV-1检测方法进行了比较。研究设计:对所有血清标本进行酶免疫分析和验证性Western blot,与快速、无仪器检测(SUDS HIV-1, Murex;TestPack艾伯特;COMBAIDS HIV 1 + 2, SPAN Diagnostics)使用各种标本来源。尿液延迟(采集后48小时)检测。快速检测的灵敏度和特异性由高到低依次为:血清SUDS HIV-1检测(100%,98.3%)、血清COMBAIDS检测(98.4%,99.6%)和OMT SUDS HIV-1检测(98.4%,94.5%)。结果:修改了OMT EIA光密度截止值,特异性从89.1提高到99.6%;然而,灵敏度从100下降到98.5%。尿液环境影响评估和快速分析表明,作为筛选试验的测试性能是不可接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Editorial Immune mediated and inherited defences against flaviviruses Maternal recognition of foetal infection with bovine virus diarrhoea virus (BVDV)—the bovine pestivirus The conformation of hepatitis C virus NS3 proteinase with and without NS4A: a structural basis for the activation of the enzyme by its cofactor Repression of the PKR protein kinase by the hepatitis C virus NS5A protein: a potential mechanism of interferon resistance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1