Modeling magnetic fields in residences: validation of the resicalc program.

L E Zaffanella, R Kavet, J R Pappa, T P Sullivan
{"title":"Modeling magnetic fields in residences: validation of the resicalc program.","authors":"L E Zaffanella,&nbsp;R Kavet,&nbsp;J R Pappa,&nbsp;T P Sullivan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>RESICALC is a computer program that models magnetic fields due to currents on arbitrary arrays and configurations of electric transmission lines, primary and secondary distribution lines, and ground and neutral return pathways. The program conducts network analyses of ground/neutral currents in neighborhoods based on residential loads and impedances in the current path. Experiments were conducted at the Magnetic Field Research Facility (MFRF) in Lenox, Massachusetts to validate the program's field computation. MFRF has a simulated residential electric distribution system that permits the testing of scenarios with a broad range of electrical characteristics. The results demonstrate that the program accurately models fields from complex combinations of supply and ground/neutral currents, and shows how estimated fields may be sensitive to impedance values assigned to the ground and neutral currents. The program has usefulness as an exposure assessment tool when access to residences is not possible, and as a means to estimate fields when planning electrical facility or residential development. Careful mapping of power line and residential coordinates in the program, as well as acquiring the highest quality load and grounding data available, are critical for modeling valid exposure estimates.</p>","PeriodicalId":15789,"journal":{"name":"Journal of Exposure Analysis and Environmental Epidemiology","volume":"7 2","pages":"241-59"},"PeriodicalIF":0.0000,"publicationDate":"1997-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Exposure Analysis and Environmental Epidemiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

RESICALC is a computer program that models magnetic fields due to currents on arbitrary arrays and configurations of electric transmission lines, primary and secondary distribution lines, and ground and neutral return pathways. The program conducts network analyses of ground/neutral currents in neighborhoods based on residential loads and impedances in the current path. Experiments were conducted at the Magnetic Field Research Facility (MFRF) in Lenox, Massachusetts to validate the program's field computation. MFRF has a simulated residential electric distribution system that permits the testing of scenarios with a broad range of electrical characteristics. The results demonstrate that the program accurately models fields from complex combinations of supply and ground/neutral currents, and shows how estimated fields may be sensitive to impedance values assigned to the ground and neutral currents. The program has usefulness as an exposure assessment tool when access to residences is not possible, and as a means to estimate fields when planning electrical facility or residential development. Careful mapping of power line and residential coordinates in the program, as well as acquiring the highest quality load and grounding data available, are critical for modeling valid exposure estimates.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
住宅磁场建模:残余程序的验证。
RESICALC是一个计算机程序,可以模拟由于电流在输电线路、一次和二次配电线路以及接地和中性回路的任意阵列和配置上产生的磁场。该计划根据住宅负荷和电流路径上的阻抗对社区的地/中性电流进行网络分析。实验在马萨诸塞州莱诺克斯的磁场研究设施(MFRF)进行,以验证程序的磁场计算。MFRF有一个模拟的住宅配电系统,允许测试具有广泛电气特性的场景。结果表明,该程序准确地模拟了电源和地/中性电流的复杂组合的场,并显示了估计的场如何对分配给地和中性电流的阻抗值敏感。当无法进入住宅时,该程序作为暴露评估工具是有用的,当规划电力设施或住宅开发时,该程序作为估计油田的一种手段是有用的。在项目中仔细绘制电力线和住宅坐标,以及获取最高质量的负载和接地数据,对于建立有效的暴露估计模型至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Volume 12 Author Index Indoor air and exposure: selected papers from INDOOR AIR 2002. Personal, indoor, and outdoor VOC exposures in a probability sample of children. Exposure assessment for respirable particulates associated with household fuel use in rural districts of Andhra Pradesh, India. Impact of improved stoves, house construction and child location on levels of indoor air pollution exposure in young Guatemalan children.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1