[Capture-R Ready-ID and DiaMed-ID for identification of erythrocyte bound antibodies after acid elution].

K H Beck, N Kaup, R Ilse, H Beeser
{"title":"[Capture-R Ready-ID and DiaMed-ID for identification of erythrocyte bound antibodies after acid elution].","authors":"K H Beck,&nbsp;N Kaup,&nbsp;R Ilse,&nbsp;H Beeser","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The DiaMed-ID (D-ID) gel system is known to be a very sensitive and specific method for the detection of red cell antibodies. In various cases, we failed to find an antibody in the eluate in which red-cell-bound antibodies (IgG) where proven by a positive direct antiglobulin test (DAT). SPRCA (Capture-R, Ready Screen, Immucor; C-R) seems also to be very sensitive, in part due to the antihuman, IgG-coated indicator cells. Therefore, we compared 39 acid eluates from patients who had a positive DAT (monospecific rabbit antihuman IgG) both in the D-ID and in the C-R system. Patients (19 female, 20 male; mean age 62 years) were suspected either to have an autoimmune hemolytic anemia or an alloantibody. Identification of the antibodies was done with the system's own panel cells. Agglutination strength was scored from 1 to 4. Quantification of selected eluates was performed by titration, using the same cells in both systems. From 39 eluates, 31 were positive in the C-R and 25 in the D-ID. Nine eluates were negative in the C-R and 14 in the D-ID. If only eluates with a DAT reaction strength of 2 or lower were considered, obviously more negative results were found with the D-ID technique (p < 0.027) than with the C-R technique. In all eluates the degree of test reaction was stronger in the C-R system. However, titration endpoints of 6 quantified antibodies did not differ significantly. In 2 patients with slightly positive DAT, antibody typing was negative or not clear in the serum. In the corresponding eluates, an anti-K and an anti-JKa could be identified only by the C-R technique. In such instances we recommend to use the C-R technique to prevent transfusion complications.</p>","PeriodicalId":79439,"journal":{"name":"Beitrage zur Infusionstherapie und Transfusionsmedizin = Contributions to infusion therapy and transfusion medicine","volume":"34 ","pages":"171-5"},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Beitrage zur Infusionstherapie und Transfusionsmedizin = Contributions to infusion therapy and transfusion medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The DiaMed-ID (D-ID) gel system is known to be a very sensitive and specific method for the detection of red cell antibodies. In various cases, we failed to find an antibody in the eluate in which red-cell-bound antibodies (IgG) where proven by a positive direct antiglobulin test (DAT). SPRCA (Capture-R, Ready Screen, Immucor; C-R) seems also to be very sensitive, in part due to the antihuman, IgG-coated indicator cells. Therefore, we compared 39 acid eluates from patients who had a positive DAT (monospecific rabbit antihuman IgG) both in the D-ID and in the C-R system. Patients (19 female, 20 male; mean age 62 years) were suspected either to have an autoimmune hemolytic anemia or an alloantibody. Identification of the antibodies was done with the system's own panel cells. Agglutination strength was scored from 1 to 4. Quantification of selected eluates was performed by titration, using the same cells in both systems. From 39 eluates, 31 were positive in the C-R and 25 in the D-ID. Nine eluates were negative in the C-R and 14 in the D-ID. If only eluates with a DAT reaction strength of 2 or lower were considered, obviously more negative results were found with the D-ID technique (p < 0.027) than with the C-R technique. In all eluates the degree of test reaction was stronger in the C-R system. However, titration endpoints of 6 quantified antibodies did not differ significantly. In 2 patients with slightly positive DAT, antibody typing was negative or not clear in the serum. In the corresponding eluates, an anti-K and an anti-JKa could be identified only by the C-R technique. In such instances we recommend to use the C-R technique to prevent transfusion complications.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Capture-R Ready-ID和DiaMed-ID用于酸洗脱后红细胞结合抗体的鉴定]。
已知DiaMed-ID (D-ID)凝胶系统是一种非常敏感和特异性的检测红细胞抗体的方法。在各种情况下,我们未能在洗脱液中找到一种抗体,其中红细胞结合抗体(IgG)被直接抗球蛋白试验(DAT)证实为阳性。SPRCA (Capture-R, Ready Screen, Immucor;C-R似乎也非常敏感,部分原因是抗人igg包被的指示细胞。因此,我们比较了来自D-ID和C-R系统中DAT(单特异性兔抗人IgG)阳性患者的39种酸洗脱液。患者中女性19例,男性20例;平均年龄62岁)被怀疑患有自身免疫性溶血性贫血或同种异体抗体。抗体的鉴定是用系统自身的面板细胞完成的。凝集强度评分为1 ~ 4分。在两种系统中使用相同的细胞,通过滴定对选定的洗脱液进行定量。39例洗脱者中,31例C-R阳性,25例D-ID阳性。9例洗脱物C-R阴性,14例D-ID阴性。如果只考虑DAT反应强度为2或更低的洗脱液,D-ID技术的阴性结果明显多于C-R技术(p < 0.027)。在所有洗脱液中,C-R体系的测试反应程度较强。6种定量抗体的滴定终点无显著差异。2例轻度阳性患者血清抗体分型阴性或不清楚。在相应的洗脱液中,只有C-R技术才能识别出抗k和抗jka。在这种情况下,我们建议使用C-R技术来防止输血并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hepatitis G virus (HGV)--association with graft failure after hematopoietic stem cell transplantation? Infection cycle of herpes viruses after photodynamic treatment with methylene blue and light. Photodynamic virus inactivation of thrombocyte concentrates by phenothiazine dyes. Comparative investigations of quality of erythrocyte concentrates in preservation media SAG-M, PAGGS-M and Adsol without and with leukocyte depletion. Transport of potassium ions in human red blood cells and lymphocyte survival in erythrocyte concentrates after gamma irradiation and during storage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1