{"title":"Closed-loop subcutaneous insulin infusion algorithm with a short-acting insulin analog for long-term clinical application of a wearable artificial endocrine pancreas.","authors":"S Shimoda, K Nishida, M Sakakida, Y Konno, K Ichinose, M Uehara, T Nowak, M Shichiri","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Considering the management and safety of the insulin delivery route when a wearable artificial endocrine pancreas is applied to ambulatory diabetic patients on a long-term basis, we developed a s.c. insulin infusion algorithm by analyzing the dynamics of a s.c. injected short-acting insulin analog (Insulin Lispro) by a three-compartment model. Principally the insulin infusion algorithm was developed as a transfer function with the first-order delay in both proportional and derivative actions to blood glucose concentrations. The parameters for this algorithm were calculated to simulate a physiological plasma insulin profile as closely as possible. By applying this algorithm with regular insulin, diabetic patients showed a 2 h postprandial hyperglycemia and a delayed hyperinsulinemia, followed by hypoglycemic episodes 4-5 h after oral glucose load, just as observed in the computer simulation study. However, using Insulin Lispro, a near-physiological glycemic control (postprandial blood glucose of 153.1 +/- 8.3 mg/100 ml at 60 min and 90.3 +/- 7.1 mg/100 ml at 180 min, respectively) could be achieved without showing any delayed hyperinsulinemia or hypoglycemia. Daily glycemic excursions were also controlled near-physiologically and although the daily insulin requirement (731.7 +/- 160.5 mU/kg/day) was slightly higher, it was not significantly different from that with i.v. insulin infusion (622.3 +/- 142.6 mU/kg/day). These results indicate that the application of s.c. insulin infusion algorithm with Insulin Lispro is feasible for long-term glycemic control with a wearable artificial endocrine pancreas in ambulatory diabetic patients.</p>","PeriodicalId":77139,"journal":{"name":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","volume":"8 3","pages":"197-211"},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Considering the management and safety of the insulin delivery route when a wearable artificial endocrine pancreas is applied to ambulatory diabetic patients on a long-term basis, we developed a s.c. insulin infusion algorithm by analyzing the dynamics of a s.c. injected short-acting insulin analog (Insulin Lispro) by a three-compartment model. Principally the insulin infusion algorithm was developed as a transfer function with the first-order delay in both proportional and derivative actions to blood glucose concentrations. The parameters for this algorithm were calculated to simulate a physiological plasma insulin profile as closely as possible. By applying this algorithm with regular insulin, diabetic patients showed a 2 h postprandial hyperglycemia and a delayed hyperinsulinemia, followed by hypoglycemic episodes 4-5 h after oral glucose load, just as observed in the computer simulation study. However, using Insulin Lispro, a near-physiological glycemic control (postprandial blood glucose of 153.1 +/- 8.3 mg/100 ml at 60 min and 90.3 +/- 7.1 mg/100 ml at 180 min, respectively) could be achieved without showing any delayed hyperinsulinemia or hypoglycemia. Daily glycemic excursions were also controlled near-physiologically and although the daily insulin requirement (731.7 +/- 160.5 mU/kg/day) was slightly higher, it was not significantly different from that with i.v. insulin infusion (622.3 +/- 142.6 mU/kg/day). These results indicate that the application of s.c. insulin infusion algorithm with Insulin Lispro is feasible for long-term glycemic control with a wearable artificial endocrine pancreas in ambulatory diabetic patients.