[Gasless video-endoscopic implantation of aortobifemoral vascular prostheses via extraperitoneal approach in the animal experiment].

B Wolfgarten, C Bruns, M Kasper, D Zenner, M Walter, B Manich
{"title":"[Gasless video-endoscopic implantation of aortobifemoral vascular prostheses via extraperitoneal approach in the animal experiment].","authors":"B Wolfgarten,&nbsp;C Bruns,&nbsp;M Kasper,&nbsp;D Zenner,&nbsp;M Walter,&nbsp;B Manich","doi":"10.1007/s004230050082","DOIUrl":null,"url":null,"abstract":"<p><p>The gasless videoendoscopic implantation of GELSOFT aortobifemoral vascular prostheses times 6 x 6 mm in diameter using an extraperitoneal approach was tested in ten porcine experimental models at the Surgical Department of the University of Cologne, Germany. Gasless videoendoscopic surgery is performed with a laparolift-laparofan system. Aortobifemoral GELSOFT prostheses were successfully implanted in nine of ten animals, whereby one animal died during preparations for surgery of massive coronary infarctions. Average surgical durations using the extraperitoneal approach were 270 min. Dissection of the infrarenal aorta until occlusion took 45 min, average aortic occlusion 75 min, and iliacofemoral occlusion 45 min for the left side and 75 min for the right side. After successful videoendoscopic implantation of aortobifemoral GELSOFT prostheses all nine animals underwent laparotomy and resection of the aortobifemoral prosthetic segment. The quality of the endoscopically sutured aortic end-to-side anastomoses was examined in vitro under artificial circulation of glycerol/Ringer's lactate solution for evaluation of possible leakage and bursting pressures and then compared to conventionally sutured end-to-side anastomoses of 6-h-old porcine abdominal aorta and GELSOFT prostheses 6 mm in diameter. The maximum bursting pressure of all endoscopically sutured anastomoses was 480 mmHg mean pressure: the minimum was 140 mmHg mean pressure. The minimum leakage per minute was less than 10 ml/min for systolic pressure values between 120 and 350 mmHg. All endoscopically sutured aortic end-to-side anastomoses were comparable to conventionally sutured anastomoses concerning in vitro evaluation of bursting pressure and leakage per minute.</p>","PeriodicalId":17985,"journal":{"name":"Langenbecks Archiv fur Chirurgie","volume":"382 6","pages":"373-9"},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Langenbecks Archiv fur Chirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s004230050082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The gasless videoendoscopic implantation of GELSOFT aortobifemoral vascular prostheses times 6 x 6 mm in diameter using an extraperitoneal approach was tested in ten porcine experimental models at the Surgical Department of the University of Cologne, Germany. Gasless videoendoscopic surgery is performed with a laparolift-laparofan system. Aortobifemoral GELSOFT prostheses were successfully implanted in nine of ten animals, whereby one animal died during preparations for surgery of massive coronary infarctions. Average surgical durations using the extraperitoneal approach were 270 min. Dissection of the infrarenal aorta until occlusion took 45 min, average aortic occlusion 75 min, and iliacofemoral occlusion 45 min for the left side and 75 min for the right side. After successful videoendoscopic implantation of aortobifemoral GELSOFT prostheses all nine animals underwent laparotomy and resection of the aortobifemoral prosthetic segment. The quality of the endoscopically sutured aortic end-to-side anastomoses was examined in vitro under artificial circulation of glycerol/Ringer's lactate solution for evaluation of possible leakage and bursting pressures and then compared to conventionally sutured end-to-side anastomoses of 6-h-old porcine abdominal aorta and GELSOFT prostheses 6 mm in diameter. The maximum bursting pressure of all endoscopically sutured anastomoses was 480 mmHg mean pressure: the minimum was 140 mmHg mean pressure. The minimum leakage per minute was less than 10 ml/min for systolic pressure values between 120 and 350 mmHg. All endoscopically sutured aortic end-to-side anastomoses were comparable to conventionally sutured anastomoses concerning in vitro evaluation of bursting pressure and leakage per minute.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[动物实验中经腹腔外入路无气视频内镜下主动脉股动脉血管假体植入术]。
德国科隆大学外科在10只猪实验模型中进行了GELSOFT主动脉股动脉血管假体的无气视频内镜植入,其直径为6 × 6mm,采用腹腔外入路。无气视频内窥镜手术是通过腹腔镜-腹腔镜系统进行的。10只动物中有9只成功植入了主动脉股动脉GELSOFT假体,其中一只动物在准备大面积冠状动脉梗死手术期间死亡。采用腹膜外入路的平均手术时间为270分钟。分离肾下主动脉至闭塞用时45分钟,平均主动脉闭塞用时75分钟,髂股动脉闭塞用时45分钟,右侧闭塞用时75分钟。在视频内镜下成功植入主动脉股动脉GELSOFT假体后,所有9只动物都进行了剖腹手术并切除了主动脉股动脉假体段。在体外人工循环甘油/乳酸林格氏液下观察经内镜缝合的主动脉端侧吻合质量,评估可能出现的漏压和破裂压力,并与常规缝合的6 h龄猪腹主动脉端侧吻合和直径为6mm的GELSOFT假体进行比较。所有经内镜缝合的吻合口最大破裂压力平均为480 mmHg,最小平均为140 mmHg。收缩压值在120 ~ 350mmhg之间时,每分钟最小泄漏量小于10ml /min。所有经内窥镜缝合的主动脉端侧吻合术在体外爆破压力和每分钟泄漏的评估方面与常规缝合的吻合术相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Abstracts 5th Tripartite Meeting Salzburg/Austria, September 9–11,1982 Fournier's gangrene: still highly lethal. Unstable fractures of the upper thoracic spine. Induction of heat shock protein 70 (HSP70) by zinc bis (DL-hydrogen aspartate) reduces ischemic small-bowel tissue damage in rats. Indications for and results of splenectomy in different hematological disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1