Evaluation of the compressive mechanical properties of endoluminal metal stents.

S C Schrader, R Beyar
{"title":"Evaluation of the compressive mechanical properties of endoluminal metal stents.","authors":"S C Schrader,&nbsp;R Beyar","doi":"10.1002/(sici)1097-0304(199806)44:2<179::aid-ccd11>3.0.co;2-i","DOIUrl":null,"url":null,"abstract":"<p><p>The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of the beStent, the Crown and the Palmaz-Schatz stent (PS153-series) were comparable. The spiral articulated Palmaz-Schatz stent showed twice the strength (1.26 atm) of the PS-153 (0.65 atm). The NIR stent yielded a maximum strength of 1.05 atm. The MICRO-II and the Wiktor stent did not collapse abruptly but rather showed a continuous decline of diameter with increasing external pressure. The Cardiocoil stent behaved in a fully elastic manner and showed the largest radial stiffness. Difference in mechanical properties between stents were documented using a new device specifically developed for that purpose. These mechanical stent parameters may have important clinical implications.</p>","PeriodicalId":9664,"journal":{"name":"Catheterization and cardiovascular diagnosis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"44","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(sici)1097-0304(199806)44:2<179::aid-ccd11>3.0.co;2-i","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 44

Abstract

The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of the beStent, the Crown and the Palmaz-Schatz stent (PS153-series) were comparable. The spiral articulated Palmaz-Schatz stent showed twice the strength (1.26 atm) of the PS-153 (0.65 atm). The NIR stent yielded a maximum strength of 1.05 atm. The MICRO-II and the Wiktor stent did not collapse abruptly but rather showed a continuous decline of diameter with increasing external pressure. The Cardiocoil stent behaved in a fully elastic manner and showed the largest radial stiffness. Difference in mechanical properties between stents were documented using a new device specifically developed for that purpose. These mechanical stent parameters may have important clinical implications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
腔内金属支架压缩力学性能的评价。
金属支架的力学性能是支架设计中考虑的重要参数,与抗动脉反冲和血管痉挛相匹配。本研究的目的是建立一套对各种冠状动脉支架的力学特性进行标准化定量评估的系统。外静水压力对几种支架进行压缩。通过在支架上放置一对小超声晶体来评估支架直径。从压力-应变图中确定每个支架的极限强度和径向刚度。除MICRO-II和Wiktor支架外,所有支架直径均均匀减小,直至超过极限抗压强度,导致突然塌陷。扩展到3mm时,beStent、Crown和Palmaz-Schatz支架(ps153系列)的力学行为是相似的。螺旋铰接Palmaz-Schatz支架的强度(1.26 atm)是PS-153支架(0.65 atm)的两倍。近红外支架的最大强度为1.05 atm。MICRO-II和Wiktor支架不是突然塌陷,而是随着外压的增加,直径持续下降。Cardiocoil支架表现为完全弹性,并显示出最大的径向刚度。使用专门为此目的开发的新设备记录了支架之间机械性能的差异。这些机械支架参数可能具有重要的临床意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of basal epicardial tone on endothelium-independent coronary flow reserve measurement. Coronary stenting in the elderly: longitudinal results in a wide spectrum of patients treated with a new and more practical approach. Diabetes Atherosclerosis Intervention Study (DAIS): quantitative coronary angiographic analysis of coronary artery atherosclerosis. Determinants of rebound thrombin activity after cessation of heparin in patients undergoing coronary interventions. Percutaneous intervention: design, technique, and pharmacology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1