Latex agglutination test for detection of tetanus antitoxins.

C L Lee, H C Huang, S Y Chiu, Y S Lee, T M Pan
{"title":"Latex agglutination test for detection of tetanus antitoxins.","authors":"C L Lee,&nbsp;H C Huang,&nbsp;S Y Chiu,&nbsp;Y S Lee,&nbsp;T M Pan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A rapid and easy method of slide agglutination test for the detection of human tetanus antitoxins was developed in this study. Testing reagents were prepared from carboxylated polystyrene latex particles with tetanus toxin by soluble carbodiimide. The test was performed on a glass slide with a drop of test sample and a drop of testing reagent. The agglutination reaction was usually completed within five minutes. Sensitivity of this test for tetanus antitoxins can be reached at 0.125 IU/ml. Therefore, the latex agglutination test can be used to determine the immune status of a patient in an emergency.</p>","PeriodicalId":24009,"journal":{"name":"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A rapid and easy method of slide agglutination test for the detection of human tetanus antitoxins was developed in this study. Testing reagents were prepared from carboxylated polystyrene latex particles with tetanus toxin by soluble carbodiimide. The test was performed on a glass slide with a drop of test sample and a drop of testing reagent. The agglutination reaction was usually completed within five minutes. Sensitivity of this test for tetanus antitoxins can be reached at 0.125 IU/ml. Therefore, the latex agglutination test can be used to determine the immune status of a patient in an emergency.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
乳胶凝集试验检测破伤风抗毒素。
本研究建立了一种快速简便的玻片凝集试验检测破伤风抗毒素的方法。以含破伤风毒素的羧化聚苯乙烯乳胶颗粒为原料,采用可溶性碳二亚胺法制备检测试剂。试验是在玻璃载玻片上用一滴测试样品和一滴测试试剂进行的。凝集反应通常在5分钟内完成。该试验对破伤风抗毒素的敏感性可达0.125 IU/ml。因此,在紧急情况下,乳胶凝集试验可用于确定患者的免疫状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Studies on the serological cross-reaction between dengue and Japanese encephalitis. Evaluation of CLO test and polymerase chain reaction for biopsy-dependent diagnosis of Helicobacter pylori infection. Purification and characterization of a 94 KD high molecular weight allergen from house dust mite, Dermatophagoides pteronyssinus. Population cell differentiation of Serratia marcescens on agar surface and in broth culture. [Detection of neutralizing antibodies to Japanese encephalitis virus by enzyme-linked immunosorbent assay (ELISA)].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1