High frequency oscillations in early cortical somatosensory evoked potentials

Isamu Ozaki , Chieko Suzuki , Yukoh Yaegashi , Masayuki Baba , Muneo Matsunaga , Isao Hashimoto
{"title":"High frequency oscillations in early cortical somatosensory evoked potentials","authors":"Isamu Ozaki ,&nbsp;Chieko Suzuki ,&nbsp;Yukoh Yaegashi ,&nbsp;Masayuki Baba ,&nbsp;Muneo Matsunaga ,&nbsp;Isao Hashimoto","doi":"10.1016/S0168-5597(98)00032-X","DOIUrl":null,"url":null,"abstract":"<div><p><strong>Objective</strong><span>: To evaluate the characteristics of high frequency (HF) components of the early cortical somatosensory evoked potentials (SEPs).</span></p><p><strong>Methods</strong><span>: We recorded 8-channel SEPs from the frontal and left centro-parietal scalp after right median nerve stimulation with a wide band-pass (0.5–2000 Hz) and digitized at 40 kHz sampling rate in 12 healthy subjects. HF components were analyzed after digital band-pass filtering (300–1000 Hz). The power spectrum was obtained by a maximum entropy method.</span></p><p><strong>Results</strong><span>: HF oscillations<span> (maximum power at 600–800 Hz) consisting of 5 to 8 peaks were discriminated from the preceding P14 far-field in all cases and their phases were reversed between the frontal and contralateral parietal regions. In addition, in subjects with a high amplitude central P22 potential in original wide-band recordings, a single HF oscillation with a maximum at the central region was present. Furthermore, this component showed no phase reversal over the centro-parietal area.</span></span></p><p><strong>Conclusion</strong>: We therefore conclude that HF oscillations are superimposed not only on the tangential N20-P20 but on the radial P22 potential, and are generated from both tangential (area 3b) and radial (area 1) current sources.</p></div>","PeriodicalId":100401,"journal":{"name":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","volume":"108 6","pages":"Pages 536-542"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0168-5597(98)00032-X","citationCount":"60","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S016855979800032X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 60

Abstract

Objective: To evaluate the characteristics of high frequency (HF) components of the early cortical somatosensory evoked potentials (SEPs).

Methods: We recorded 8-channel SEPs from the frontal and left centro-parietal scalp after right median nerve stimulation with a wide band-pass (0.5–2000 Hz) and digitized at 40 kHz sampling rate in 12 healthy subjects. HF components were analyzed after digital band-pass filtering (300–1000 Hz). The power spectrum was obtained by a maximum entropy method.

Results: HF oscillations (maximum power at 600–800 Hz) consisting of 5 to 8 peaks were discriminated from the preceding P14 far-field in all cases and their phases were reversed between the frontal and contralateral parietal regions. In addition, in subjects with a high amplitude central P22 potential in original wide-band recordings, a single HF oscillation with a maximum at the central region was present. Furthermore, this component showed no phase reversal over the centro-parietal area.

Conclusion: We therefore conclude that HF oscillations are superimposed not only on the tangential N20-P20 but on the radial P22 potential, and are generated from both tangential (area 3b) and radial (area 1) current sources.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
早期皮层体感诱发电位的高频振荡
目的:探讨早期皮层体感诱发电位(SEPs)高频成分的特征。方法:对12名健康受试者进行右正中神经宽带通(0.5 ~ 2000 Hz)刺激后的额叶头皮和左中脑顶叶头皮8通道电电位记录,并以40 kHz采样率进行数字化处理。经过300 ~ 1000hz的数字带通滤波,分析高频分量。功率谱采用最大熵法得到。结果:在所有病例中,高频振荡(最大功率600 ~ 800 Hz)由5 ~ 8个峰组成,与前面的P14远场相区分,其相位在额侧和对侧顶叶区之间相反。此外,在原始宽带记录中具有高振幅中央P22电位的受试者中,存在单个高频振荡,在中央区域有最大值。此外,该成分在中央顶叶区没有显示相位反转。结论:我们因此得出结论,高频振荡不仅叠加在切向N20-P20电位上,而且叠加在径向P22电位上,并且由切向(区域3b)和径向(区域1)电流源产生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Visual Evoked Potentials Clinical Evoked Potentials: An Illustrated Manual Somatosensory Evoked Potentials Motor Evoked Potentials Cochlear implant performance and electrically-evoked auditory brain-stem response characteristics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1