Noncemented tibial components: does a stem help?

Contemporary orthopaedics Pub Date : 1992-03-01
H U Cameron
{"title":"Noncemented tibial components: does a stem help?","authors":"H U Cameron","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A prospective, nonrandomized study was conducted in an attempt to determine if the addition of a stem to the tibial component in noncemented total knee replacement reduces the incidence of sinkage. A stemmed tibial component was used in 125 cases and an identical artificial knee without a stem was used in 307 cases. Follow-up was two to six years. Sinkage occurred in 0.8% of the cases with stemmed tibial components and in 3.5% of the nonstemmed tibial components, among which two (0.8%) required revision. The clinical results for both groups were similar. A small group of 34 patients who had a stemmed tibial component on one side and a nonstemmed component on the other also were examined. Fifty percent of these patients preferred the stemmed component knee. The results of these studies suggest that the addition of a stem to the tibial component in noncemented total knee replacement is of value in preventing tibial sinkage.</p>","PeriodicalId":79846,"journal":{"name":"Contemporary orthopaedics","volume":"24 3","pages":"326-30"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary orthopaedics","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A prospective, nonrandomized study was conducted in an attempt to determine if the addition of a stem to the tibial component in noncemented total knee replacement reduces the incidence of sinkage. A stemmed tibial component was used in 125 cases and an identical artificial knee without a stem was used in 307 cases. Follow-up was two to six years. Sinkage occurred in 0.8% of the cases with stemmed tibial components and in 3.5% of the nonstemmed tibial components, among which two (0.8%) required revision. The clinical results for both groups were similar. A small group of 34 patients who had a stemmed tibial component on one side and a nonstemmed component on the other also were examined. Fifty percent of these patients preferred the stemmed component knee. The results of these studies suggest that the addition of a stem to the tibial component in noncemented total knee replacement is of value in preventing tibial sinkage.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非骨水泥胫骨假体:支架有帮助吗?
进行了一项前瞻性、非随机研究,试图确定在非骨水泥全膝关节置换术中向胫骨构件添加假体是否能减少内陷的发生率。125例使用有柄胫骨假体,307例使用无柄相同的人工膝关节。随访时间为2至6年。有胫骨干性假体的病例中有0.8%发生内陷,无胫骨干性假体的病例中有3.5%发生内陷,其中2例(0.8%)需要翻修。两组临床结果相似。一小组34例患者,其中一侧有胫骨干构件,另一侧无胫骨干构件也进行了检查。这些患者中有50%的人更喜欢有柄的膝关节。这些研究的结果表明,在非骨水泥全膝关节置换术中,在胫骨部件上增加一个柄在防止胫骨下沉方面有价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Management of supracondylar fractures proximal to total knee arthroplasty with the GSH supracondylar nail. Allograft safety: viral inactivation with bone demineralization. Pyogenic vertebral osteomyelitis: report of a series of 23 patients. Difficulty in removal of the distal locking device of the Brooker-Wills tibial nail. Symposium: management of infections in total joint replacements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1