{"title":"Latency to CNS oxygen toxicity in rats as a function of PCO(2) and PO(2).","authors":"R Arieli, O Ertracht","doi":"10.1007/s004210050640","DOIUrl":null,"url":null,"abstract":"<p><p>Central nervous system (CNS) oxygen toxicity can occur as convulsions and loss of consciousness, without any premonitory symptoms. We have made a quantitative study of the effect of inspired carbon dioxide on sensitivity to oxygen toxicity in the rat. Rats were exposed to four oxygen pressures (PO(2); 456, 507, 608 and 709 kPa) and an inspired partial pressure of carbon dioxide (PCO(2)) in the range 0-12 kPa until the appearance of the electroencephalograph first electrical discharge (FED) that precedes the clinical convulsions. Exposures were conducted at a thermoneutral temperature of 27 degrees C. Latency to the FED decreased linearly with the increase in PCO(2) at all four PO(2) values studied. This decrease, which is probably related to the cerebral vasodilatory effect of carbon dioxide, reached a minimal value that remained constant on further elevation of PCO(2). The slopes (absolute value) and intercepts of latency to the FED as a function of carbon dioxide decreased with the increase in PO(2). This log-linear relationship made possible the derivation of equations that describe latency to the FED as a function of both PO(2) and PCO(2) in the PCO(2) - dependent range: Latency (min) = e((5.19-0.0040)(P)(O(2)))-e((2.77-0.0034)(P)(O(2))) x PCO(2) (kPa), and in the PCO(2)-independent range: Latency(min) = e((2.44-0. 0009)(P)(O(2))). A PCO(2) as low as 1 kPa significantly reduced the latency to the FED. It is suggested that in closed-circuit oxygen diving, any accumulation of carbon dioxide should be avoided in order to minimize the risk of CNS oxygen toxicity.</p>","PeriodicalId":11936,"journal":{"name":"European Journal of Applied Physiology and Occupational Physiology","volume":"80 6","pages":"598-603"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s004210050640","citationCount":"27","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Applied Physiology and Occupational Physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s004210050640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27
Abstract
Central nervous system (CNS) oxygen toxicity can occur as convulsions and loss of consciousness, without any premonitory symptoms. We have made a quantitative study of the effect of inspired carbon dioxide on sensitivity to oxygen toxicity in the rat. Rats were exposed to four oxygen pressures (PO(2); 456, 507, 608 and 709 kPa) and an inspired partial pressure of carbon dioxide (PCO(2)) in the range 0-12 kPa until the appearance of the electroencephalograph first electrical discharge (FED) that precedes the clinical convulsions. Exposures were conducted at a thermoneutral temperature of 27 degrees C. Latency to the FED decreased linearly with the increase in PCO(2) at all four PO(2) values studied. This decrease, which is probably related to the cerebral vasodilatory effect of carbon dioxide, reached a minimal value that remained constant on further elevation of PCO(2). The slopes (absolute value) and intercepts of latency to the FED as a function of carbon dioxide decreased with the increase in PO(2). This log-linear relationship made possible the derivation of equations that describe latency to the FED as a function of both PO(2) and PCO(2) in the PCO(2) - dependent range: Latency (min) = e((5.19-0.0040)(P)(O(2)))-e((2.77-0.0034)(P)(O(2))) x PCO(2) (kPa), and in the PCO(2)-independent range: Latency(min) = e((2.44-0. 0009)(P)(O(2))). A PCO(2) as low as 1 kPa significantly reduced the latency to the FED. It is suggested that in closed-circuit oxygen diving, any accumulation of carbon dioxide should be avoided in order to minimize the risk of CNS oxygen toxicity.