{"title":"[Comparison of immunoassay kits for detection of staphylococcal enterotoxins produced by Staphylococcus aureus].","authors":"T M Pan, Y L Yu, S I Chiu, S S Lin","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>Four commercial kits, SET-RPLA, RIDASCREEN, SET-EIA, and TECRA, were compared for the efficiency of detecting staphylococcal enterotoxins (SE). There was no non-specific reaction for detection of SE produced by 21 Staphylococcus aureus strains from 5 outbreaks of food poisoning using SET-RPLA, SET-EIA and TECRA kits. The background of the results of RIDASCREEN kit was high and non-specific reactions were present in some strains.</p><p><strong>In conclusion: </strong>(i) TECRA kit is suggested to be used for screening SE producing strains; (ii) SET-RPLA and RIDASCREEN kits are suitable for epidemiological investigation of SE types, but the lack of ability for detecting SEE, long time required for testing with SET-RPLA kit and high background when using RIDASCREEN kit must be overcome; and (iii) because of the complicated test procedures and the lack of ability for detecting SEE, the practicality of SET-EIA kit in screening and epidemiological research purposes is low.</p>","PeriodicalId":24009,"journal":{"name":"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Unlabelled: Four commercial kits, SET-RPLA, RIDASCREEN, SET-EIA, and TECRA, were compared for the efficiency of detecting staphylococcal enterotoxins (SE). There was no non-specific reaction for detection of SE produced by 21 Staphylococcus aureus strains from 5 outbreaks of food poisoning using SET-RPLA, SET-EIA and TECRA kits. The background of the results of RIDASCREEN kit was high and non-specific reactions were present in some strains.
In conclusion: (i) TECRA kit is suggested to be used for screening SE producing strains; (ii) SET-RPLA and RIDASCREEN kits are suitable for epidemiological investigation of SE types, but the lack of ability for detecting SEE, long time required for testing with SET-RPLA kit and high background when using RIDASCREEN kit must be overcome; and (iii) because of the complicated test procedures and the lack of ability for detecting SEE, the practicality of SET-EIA kit in screening and epidemiological research purposes is low.