{"title":"Increasing the safety of volumetric ultrafiltration control.","authors":"H Peter","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Deviations in ultrafiltration volume can cause various problems for patients undergoing a haemodialysis treatment. With the introduction of high flux dialysers, closed systems with volumetric fluid balancing became the systems of choice, because control of transmembrane pressure used previously is too inaccurate and unsafe to be used with such filters. In this article, a reliable and cost effective test method is described to increase the safety of a closed system. The test is carried out by simply analysing the dialysate pressure while the dialyser is isolated from the system for typically 7.2 seconds. No additional sensors and components other then a valve combination used to isolate the dialyser are required.</p>","PeriodicalId":79589,"journal":{"name":"EDTNA/ERCA journal (English ed.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EDTNA/ERCA journal (English ed.)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Deviations in ultrafiltration volume can cause various problems for patients undergoing a haemodialysis treatment. With the introduction of high flux dialysers, closed systems with volumetric fluid balancing became the systems of choice, because control of transmembrane pressure used previously is too inaccurate and unsafe to be used with such filters. In this article, a reliable and cost effective test method is described to increase the safety of a closed system. The test is carried out by simply analysing the dialysate pressure while the dialyser is isolated from the system for typically 7.2 seconds. No additional sensors and components other then a valve combination used to isolate the dialyser are required.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
提高容积超滤控制的安全性。
超滤体积的偏差会给接受血液透析治疗的患者带来各种问题。随着高通量透析器的引入,具有体积流体平衡的封闭系统成为首选系统,因为以前使用的跨膜压力控制太不准确且不安全,无法与此类过滤器一起使用。本文介绍了一种可靠且经济有效的测试方法,以提高封闭系统的安全性。当透析器与系统隔离通常为7.2秒时,通过简单地分析透析液压力来进行测试。除了用于隔离透析器的阀门组合外,不需要额外的传感器和组件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Merits and limitations of continuous blood volume monitoring during haemodialysis. Summary of the EDTNA/ERCA Journal Club discussion: Winter 2005. Why clown-doctors are needed in paediatric wards. Telephone interview with Fresenius Medical Care project leader Mr. Jonas: launch of 5008 Therapy System. The use of telemedicine to assess and advise patients regarding dietary treatment of hyperphosphataemia. The conductivity of dialysis fluid.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1