{"title":"Characterization of acromial concavity. An in vitro computer analysis.","authors":"J D Zuckerman,&nbsp;F J Kummer,&nbsp;S N Panos","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Variations in the shape and orientation of the anterior acromion have been implicated as predisposing factors for the development of rotator cuff problems. We determined and analyzed by computer digitization the anterior and posterior acromial slopes for 141 cadaver shoulders (whose rotator cuff status had been previously assessed). No significant differences in either the anterior or posterior angle were found between the intact and rotator cuff tear groups. Frequency histograms of both angles demonstrated continuous, normal distributions. The individual acromions were consistently asymmetric in that the anterior slope was larger than the posterior slope. However, the anterior slope distribution did not reveal groupings indicative of the specific acromial types previously reported. These results suggest that acromial classification into flat, curved, and hooked types does not accurately describe the actual anatomical findings.</p>","PeriodicalId":77050,"journal":{"name":"Bulletin (Hospital for Joint Diseases (New York, N.Y.))","volume":"59 2","pages":"69-72"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin (Hospital for Joint Diseases (New York, N.Y.))","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Variations in the shape and orientation of the anterior acromion have been implicated as predisposing factors for the development of rotator cuff problems. We determined and analyzed by computer digitization the anterior and posterior acromial slopes for 141 cadaver shoulders (whose rotator cuff status had been previously assessed). No significant differences in either the anterior or posterior angle were found between the intact and rotator cuff tear groups. Frequency histograms of both angles demonstrated continuous, normal distributions. The individual acromions were consistently asymmetric in that the anterior slope was larger than the posterior slope. However, the anterior slope distribution did not reveal groupings indicative of the specific acromial types previously reported. These results suggest that acromial classification into flat, curved, and hooked types does not accurately describe the actual anatomical findings.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肩峰凹陷的特征。体外计算机分析。
前肩峰的形状和方向的变化被认为是肩袖问题发生的易感因素。我们通过计算机数字化确定并分析了141具尸体肩部的前、后肩峰斜度(其肩袖状态先前已被评估)。在完整组和肩袖撕裂组之间,前后角均无显著差异。两个角度的频率直方图显示连续的正态分布。个体肩峰始终不对称,前斜大于后斜。然而,前坡分布并没有显示先前报道的特定肩峰类型的分组。这些结果表明,将肩峰分为平型、弯型和钩型并不能准确描述实际解剖结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Acetabular Fractures in the Elderly The effect of interference screw diameter on soft tissue graft fixation. The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Slipped capital femoral epiphysis in identical twins: is there an HLA predisposition? Report of a case and review of the literature. Loose bodies in a sublabral recess: diagnosis and treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1