D D M Spicer, J I Curry, D L Pomeroy, W E Badenhausen, L A Schaper, K E Suthers, M W Smith
{"title":"Range of motion after arthroplasty for the stiff osteoarthritic knee.","authors":"D D M Spicer, J I Curry, D L Pomeroy, W E Badenhausen, L A Schaper, K E Suthers, M W Smith","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In 28 of 1656 total knee arthroplasties (TKAs) (1.7%) performed for osteoarthritis at this institution, the preoperative arc of motion was 60 degrees or less (average 47.5 degrees; range, 20-60 degrees). The outcome of 22 of the 28 TKAs (21 patients) is reported at a mean follow-up of 52.9 months (range, 24-144 months). Eighty-two percent of the cases were managed with standard soft-tissue releases and posterior cruciate-retaining implants and 18% with a cruciate-substituting design. The joint score rose from 28.8 to 82.2 and the Knee Society Score from 24.6 to 77 points. The mean postoperative arc of motion improved by 46 degrees-93.5 degrees. At latest follow-up, 68.2% of knees achieved maximal flexion of 90 degrees or more. Manipulation was performed in 22.7%. Complications were minimal. A functionally useful range of motion is possible after total knee arthroplasty in the majority of stiff osteoarthritic knees, often without the need for posterior cruciate substitution.</p>","PeriodicalId":79349,"journal":{"name":"Journal of the Southern Orthopaedic Association","volume":"11 4","pages":"227-30"},"PeriodicalIF":0.0000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Southern Orthopaedic Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In 28 of 1656 total knee arthroplasties (TKAs) (1.7%) performed for osteoarthritis at this institution, the preoperative arc of motion was 60 degrees or less (average 47.5 degrees; range, 20-60 degrees). The outcome of 22 of the 28 TKAs (21 patients) is reported at a mean follow-up of 52.9 months (range, 24-144 months). Eighty-two percent of the cases were managed with standard soft-tissue releases and posterior cruciate-retaining implants and 18% with a cruciate-substituting design. The joint score rose from 28.8 to 82.2 and the Knee Society Score from 24.6 to 77 points. The mean postoperative arc of motion improved by 46 degrees-93.5 degrees. At latest follow-up, 68.2% of knees achieved maximal flexion of 90 degrees or more. Manipulation was performed in 22.7%. Complications were minimal. A functionally useful range of motion is possible after total knee arthroplasty in the majority of stiff osteoarthritic knees, often without the need for posterior cruciate substitution.