Influence of the frequency of Er:YAG laser on the bond strength of dental enamel.

Mariane Gonçalves, Silmara Aparecida Milori Corona, Jesus Djalma Pécora, Regina Guenka Palma Dibb
{"title":"Influence of the frequency of Er:YAG laser on the bond strength of dental enamel.","authors":"Mariane Gonçalves,&nbsp;Silmara Aparecida Milori Corona,&nbsp;Jesus Djalma Pécora,&nbsp;Regina Guenka Palma Dibb","doi":"10.1089/104454703765035538","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The present study had the aim of evaluating the influence of different frequencies of the Er:YAG laser on adhesive resistance of enamel and one restorative system.</p><p><strong>Background data: </strong>There have been no reports of studies assessing the influence of the pulse frequency variation of the Er:YAG laser on adhesive resistance of the enamel/resin interface.</p><p><strong>Materials and methods: </strong>Fifty surfaces of enamel from extracted human third molars were planed and divided into five groups at random. Enamel surface treatment was realized by the Er:YAG laser at 80-mJ power and 1-, 2-, 3-, and 4-Hz pulse frequencies, followed by etching. For the control group, only acid conditioning with 37% phosphoric acid for 15 sec was used. The Single Bond/Filtek Z250 system was chosen for the fabrication of the specimens, which were stored in 100% relative humidity for 24 h, at 37 degrees C. The specimens were submitted to tensile resistance tests using a Universal Testing Machine (50 Kgf and 0.5 mm/min).</p><p><strong>Results: </strong>The mean values in MPa were 1 Hz, 25.58 (+/-6.16); 2 Hz, 25.58 (+/-3.79); 3 Hz, 21.34 (+/-3.78); 4 Hz, 21.17 (+/-3.13); and phosphoric acid only, 22.44 (+/-7.0). Data were submitted to statistical analysis using ANOVA, and there was no significant difference in tensile resistance between the studied groups.</p><p><strong>Conclusion: </strong>The results suggest that the Er:YAG laser, with 80-mJ power associated with acid conditioning at 1-, 2-, 3-, and 4-Hz frequencies, did not present significant improvement in tensile bonding of enamel, as compared to acid conditioning only.</p>","PeriodicalId":79503,"journal":{"name":"Journal of clinical laser medicine & surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/104454703765035538","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical laser medicine & surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/104454703765035538","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

Abstract

Objective: The present study had the aim of evaluating the influence of different frequencies of the Er:YAG laser on adhesive resistance of enamel and one restorative system.

Background data: There have been no reports of studies assessing the influence of the pulse frequency variation of the Er:YAG laser on adhesive resistance of the enamel/resin interface.

Materials and methods: Fifty surfaces of enamel from extracted human third molars were planed and divided into five groups at random. Enamel surface treatment was realized by the Er:YAG laser at 80-mJ power and 1-, 2-, 3-, and 4-Hz pulse frequencies, followed by etching. For the control group, only acid conditioning with 37% phosphoric acid for 15 sec was used. The Single Bond/Filtek Z250 system was chosen for the fabrication of the specimens, which were stored in 100% relative humidity for 24 h, at 37 degrees C. The specimens were submitted to tensile resistance tests using a Universal Testing Machine (50 Kgf and 0.5 mm/min).

Results: The mean values in MPa were 1 Hz, 25.58 (+/-6.16); 2 Hz, 25.58 (+/-3.79); 3 Hz, 21.34 (+/-3.78); 4 Hz, 21.17 (+/-3.13); and phosphoric acid only, 22.44 (+/-7.0). Data were submitted to statistical analysis using ANOVA, and there was no significant difference in tensile resistance between the studied groups.

Conclusion: The results suggest that the Er:YAG laser, with 80-mJ power associated with acid conditioning at 1-, 2-, 3-, and 4-Hz frequencies, did not present significant improvement in tensile bonding of enamel, as compared to acid conditioning only.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Er:YAG激光频率对牙釉质粘结强度的影响。
目的:研究不同频率Er:YAG激光对牙釉质和一种修复系统的粘附阻力的影响。背景资料:目前尚未有研究报告评估Er:YAG激光脉冲频率变化对牙釉质/树脂界面粘附阻力的影响。材料与方法:将拔除的人第三磨牙牙釉质50个表面刨平,随机分为5组。采用功率为80 mj、脉冲频率为1-、2-、3-和4-Hz的Er:YAG激光进行搪瓷表面处理,然后进行蚀刻。对照组仅用37%磷酸酸调理15秒。选择Single Bond/Filtek Z250系统制作样品,在100%相对湿度下,在37℃下储存24小时。样品使用通用试验机(50 Kgf, 0.5 mm/min)进行拉伸阻力测试。结果:MPa平均值为1 Hz, 25.58(±6.16);2 Hz, 25.58 (+/-3.79);3 Hz, 21.34 (+/-3.78);4 Hz, 21.17 (+/-3.13);仅磷酸,22.44(+/-7.0)。数据采用方差分析进行统计分析,实验组间抗拉能力无显著差异。结论:结果表明,与仅酸调理相比,80 mj功率的Er:YAG激光在1-、2-、3-和4-Hz频率下进行酸调理,对牙釉质的拉伸结合没有明显改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimal dye concentration and irradiance for laser-assisted vascular anastomosis. Cleaning of the root canal using Nd:YAP laser and its effect on the mineral content of the dentin. Evaluation of trans-scleral diode laser using diopexy probe for subfoveal choroidal neovascular membrane in age-related macular degeneration. Safety parameters for pulp temperature during selective ablation of caries by KTP laser in vitro. Investigation of the supplementary effect of GaAs laser therapy on the rehabilitation of human digital flexor tendons.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1