Echocardiographic assessment of the Ionescu-Shiley pericardial xenograft in the aortic position.

Cardiovascular diseases Pub Date : 1981-06-01
Leonard W. Pechacek, Luis Solana, Carlos M. Decastro
{"title":"Echocardiographic assessment of the Ionescu-Shiley pericardial xenograft in the aortic position.","authors":"Leonard W. Pechacek,&nbsp;Luis Solana,&nbsp;Carlos M. Decastro","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Echocardiograms of 30 patients with a normally functioning Ionescu-Shiley pericardial xenograft valve in the aortic position were analyzed to delineate the ultrasonic patterns produced by this bioprosthesis. The pericardial leaflets were recorded as thin, discrete echoes that were similar in configuration to the native aortic valve. Maximum systolic excursion of the anterior and posterior leaflets was 19 +/- 0.22 mm (standard deviation.) The presence of multiple echoes produced by the titanium frame was the major technical limitation to echocardiographic imaging of valve motion.</p>","PeriodicalId":84396,"journal":{"name":"Cardiovascular diseases","volume":"8 2","pages":"210-215"},"PeriodicalIF":0.0000,"publicationDate":"1981-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC287918/pdf/cardiodis00002-0060.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular diseases","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Echocardiograms of 30 patients with a normally functioning Ionescu-Shiley pericardial xenograft valve in the aortic position were analyzed to delineate the ultrasonic patterns produced by this bioprosthesis. The pericardial leaflets were recorded as thin, discrete echoes that were similar in configuration to the native aortic valve. Maximum systolic excursion of the anterior and posterior leaflets was 19 +/- 0.22 mm (standard deviation.) The presence of multiple echoes produced by the titanium frame was the major technical limitation to echocardiographic imaging of valve motion.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声心动图评价在主动脉位置的Ionescu-Shiley异种心包移植。
我们分析了30例在主动脉位置有正常功能的Ionescu-Shiley心包异种移植瓣膜的患者的超声心动图,以描绘这种生物假体产生的超声模式。心包小叶被记录为薄而离散的回声,其结构与原主动脉瓣相似。前后小叶最大收缩偏移为19±0.22 mm(标准差)。钛框架产生的多重回声是瓣膜运动超声心动图成像的主要技术限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PULMONARY VALVE ATRESIA WITH INTACT VENTRICULAR SEPTUM. Venous volume displacement plethysmography: Its diagnostic value in deep venous thrombosis as determined by receiver operator characteristic curves. Blood velocity measurement in human conjunctival vessels. Dextrocardia with situs inversus totalis: Cardiovascular surgery in three patients with concomitant coronary artery disease. Chronic traumatic popliteal arteriovenous fistula: Case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1