Erdogan Ilkay, Ihsan A Günal, Mustafa Yavuzkir, Necati Dağli, Ilgin Karaca, Huseyin Celiker, Ayhan Doğukan, Nadi Arslan
{"title":"Effect of renal artery stenting on renal function in patients with ischemic nephropathy.","authors":"Erdogan Ilkay, Ihsan A Günal, Mustafa Yavuzkir, Necati Dağli, Ilgin Karaca, Huseyin Celiker, Ayhan Doğukan, Nadi Arslan","doi":"10.1536/jhj.45.637","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the effects of stenting on blood pressure and renal functions in azotemic patients with proximal/ostial atherosclerotic renal artery stenosis. Thirteen azotemic patients (5 females, 8 males, average age, 62.7 +/- 8.3 years) who had renal artery stenosis were included in the study. Their blood pressure, estimated glomerular filtration rate (EGFR), and creatinine levels were measured at baseline and during follow-up. Stents were implanted successfully in all of the cases. The average stent diameter and stent length were 7.2 +/- 0.5 mm and 17.2 +/- 3.4 mm, respectively. Antihypertensive drug was abandoned in 1 (7.6%) patient, reduced in 10 patients (76.9%), and not changed in 2 (15.3%) patients. Significant improvement was observed in the mean serum creatinine level at the 12th month when compared with baseline (2.56 +/- 0.88; 1.83 +/- 0.62, P < 0.001). EGFR was 18.38 +/- 4.64 before the procedure and 22.67 +/- 3.81 during follow-up (P < 0.0001). According to the GFR criteria, renal function was determined to be worse in 1 (7.6%) patient, stabilized in 2 (15.3%), and improved in 10 (76.9%) patients. One patient died during the follow-up period. Angiographic restenosis was observed in 2 (15.3%) patients. Follow-up major events were observed in 3 (23%) patients. Stenting azotemic patients with renal artery stenosis is a reliable and effective procedure for achieving an improvement in renal function.</p>","PeriodicalId":14717,"journal":{"name":"Japanese heart journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese heart journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1536/jhj.45.637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
The aim of this study was to evaluate the effects of stenting on blood pressure and renal functions in azotemic patients with proximal/ostial atherosclerotic renal artery stenosis. Thirteen azotemic patients (5 females, 8 males, average age, 62.7 +/- 8.3 years) who had renal artery stenosis were included in the study. Their blood pressure, estimated glomerular filtration rate (EGFR), and creatinine levels were measured at baseline and during follow-up. Stents were implanted successfully in all of the cases. The average stent diameter and stent length were 7.2 +/- 0.5 mm and 17.2 +/- 3.4 mm, respectively. Antihypertensive drug was abandoned in 1 (7.6%) patient, reduced in 10 patients (76.9%), and not changed in 2 (15.3%) patients. Significant improvement was observed in the mean serum creatinine level at the 12th month when compared with baseline (2.56 +/- 0.88; 1.83 +/- 0.62, P < 0.001). EGFR was 18.38 +/- 4.64 before the procedure and 22.67 +/- 3.81 during follow-up (P < 0.0001). According to the GFR criteria, renal function was determined to be worse in 1 (7.6%) patient, stabilized in 2 (15.3%), and improved in 10 (76.9%) patients. One patient died during the follow-up period. Angiographic restenosis was observed in 2 (15.3%) patients. Follow-up major events were observed in 3 (23%) patients. Stenting azotemic patients with renal artery stenosis is a reliable and effective procedure for achieving an improvement in renal function.