[Feasibility of CT attenuation values in the diagnosis of anemia].

Youichi Sato, Eito Kozawa, Shunji Tsukuda, Makoto Amanuma
{"title":"[Feasibility of CT attenuation values in the diagnosis of anemia].","authors":"Youichi Sato,&nbsp;Eito Kozawa,&nbsp;Shunji Tsukuda,&nbsp;Makoto Amanuma","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To verify the possible correlation between CT attenuation value and hemoglobin (Hb).</p><p><strong>Materials and methods: </strong>CT attenuation was evaluated in 113 CT studies. Anemia was defined as an Hb level less than 14 g/dl in males and less than 12 g/dl in females. Hb was compared visually by grading (Grade 1: cardiac muscle density much higher than lumen, Grade 2: cardiac muscle density higher than lumen, Grade 3: cardiac muscle density equal to lumen), and with HU of CT attenuation on unpaired t-test (p<0.01). Correlations were calculated using the linear regression method.</p><p><strong>Results: </strong>Hb of less than 6 g/dl was found to be Grade 1, while that over 12 g/dl was considered Grade 3 on visual grading. The attenuation numbers of subjects with anemia yielded low values, whereas those of normal subjects were higher. There were significant differences between subjects with anemia and normal subjects (p<0.01). HU versus hemoglobin showed a linear increase, with a correlation coefficient of 0.76.</p><p><strong>Conclusions: </strong>This simple, readily available information may provide a valuable adjunct in the interpretation of CT examinations.</p>","PeriodicalId":19251,"journal":{"name":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","volume":"64 7","pages":"394-7"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To verify the possible correlation between CT attenuation value and hemoglobin (Hb).

Materials and methods: CT attenuation was evaluated in 113 CT studies. Anemia was defined as an Hb level less than 14 g/dl in males and less than 12 g/dl in females. Hb was compared visually by grading (Grade 1: cardiac muscle density much higher than lumen, Grade 2: cardiac muscle density higher than lumen, Grade 3: cardiac muscle density equal to lumen), and with HU of CT attenuation on unpaired t-test (p<0.01). Correlations were calculated using the linear regression method.

Results: Hb of less than 6 g/dl was found to be Grade 1, while that over 12 g/dl was considered Grade 3 on visual grading. The attenuation numbers of subjects with anemia yielded low values, whereas those of normal subjects were higher. There were significant differences between subjects with anemia and normal subjects (p<0.01). HU versus hemoglobin showed a linear increase, with a correlation coefficient of 0.76.

Conclusions: This simple, readily available information may provide a valuable adjunct in the interpretation of CT examinations.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
【CT衰减值在贫血诊断中的可行性】。
目的:验证CT衰减值与血红蛋白(Hb)的可能相关性。材料和方法:对113例CT研究进行了CT衰减评价。贫血被定义为男性Hb水平低于14g /dl,女性低于12g /dl。通过视觉分级(1级:心肌密度远高于管腔,2级:心肌密度高于管腔,3级:心肌密度等于管腔)和未配对t检验的CT衰减HU(结果:Hb小于6 g/dl为1级,大于12 g/dl为3级视觉分级)比较Hb。贫血受试者的衰减值较低,而正常受试者的衰减值较高。结论:这种简单、容易获得的信息可能为CT检查的解释提供有价值的辅助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Abstracts of the 45th Autumn Meeting of the Japanese Radiological Society. October 29-31, 2009. Wakayama, Japan]. [Abstracts of the 68th Annual Meeting of the Japanese Radiological Society. April 16-19, 2009. Yokohama, Japan]. [The 44th Autumn Meeting of the Japanese Radiological Society. Fukushima, Japan. October 22-24, 2008. Abstracts]. [The 67th Annual Meeting of the Japanese Radiological Society. Yokohama, Japan. April 4-6, 2008. Abstracts]. [The 43rd autumn meeting of the Japan Radiological Society. Nagoya, Japan. October 25-27, 2007. Abstracts].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1