Planar Tc99m--sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: results of an international multicenter trial.

Teresa Massardo, Omar Alonso, Augusto Llamas-Ollier, Levin Kabasakal, Uma Ravishankar, Rossana Morales, Lucía Delgado, Ajit K Padhy
{"title":"Planar Tc99m--sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: results of an international multicenter trial.","authors":"Teresa Massardo,&nbsp;Omar Alonso,&nbsp;Augusto Llamas-Ollier,&nbsp;Levin Kabasakal,&nbsp;Uma Ravishankar,&nbsp;Rossana Morales,&nbsp;Lucía Delgado,&nbsp;Ajit K Padhy","doi":"10.1186/1471-2385-5-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Lymph node status is the most important prognostic indicator in breast cancer in recently diagnosed primary lesion. As a part of an interregional protocol using scintimammography with Tc99m compounds, the value of planar Tc99m sestamibi scanning for axillary lymph node evaluation is presented. Since there is a wide range of reported values, a standardized protocol of planar imaging was performed.</p><p><strong>Methods: </strong>One hundred and forty-nine female patients were included prospectively from different regions. Their mean age was 55.1 +/- 11.9 years. Histological report was obtained from 2.987 excised lymph nodes from 150 axillas. An early planar chest image was obtained at 10 min in all patients and a delayed one in 95 patients, all images performed with 740-925 MBq dose of Tc99m sestamibi. Blind lecture of all axillary regions was interpreted by 2 independent observers considering any well defined focal area of increased uptake as an involved axilla. Diagnostic values, 95% confidence intervals [CI] and also likelihood ratios (LR) were calculated.</p><p><strong>Results: </strong>Node histology demonstrated tumor involvement in 546 out of 2987 lymph nodes. Sestamibi was positive in 30 axillas (25 true-positive) and negative in 120 (only 55 true-negative). The sensitivity corresponded to 27.8% [CI = 18.9-38.2] and specificity to 91.7% [81.6-97.2]. The positive and negative LR were 3.33 and 0.79, respectively. There was no difference between early and delayed images. Sensitivity was higher in patients with palpable lesions.</p><p><strong>Conclusion: </strong>This work confirmed that non tomographic Tc99m sestamibi scintimammography had a very low detection rate for axillary lymph node involvement and it should not be applied for clinical assessment of breast cancer.</p>","PeriodicalId":80684,"journal":{"name":"BMC nuclear medicine","volume":"5 ","pages":"4"},"PeriodicalIF":0.0000,"publicationDate":"2005-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1471-2385-5-4","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC nuclear medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1471-2385-5-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Background: Lymph node status is the most important prognostic indicator in breast cancer in recently diagnosed primary lesion. As a part of an interregional protocol using scintimammography with Tc99m compounds, the value of planar Tc99m sestamibi scanning for axillary lymph node evaluation is presented. Since there is a wide range of reported values, a standardized protocol of planar imaging was performed.

Methods: One hundred and forty-nine female patients were included prospectively from different regions. Their mean age was 55.1 +/- 11.9 years. Histological report was obtained from 2.987 excised lymph nodes from 150 axillas. An early planar chest image was obtained at 10 min in all patients and a delayed one in 95 patients, all images performed with 740-925 MBq dose of Tc99m sestamibi. Blind lecture of all axillary regions was interpreted by 2 independent observers considering any well defined focal area of increased uptake as an involved axilla. Diagnostic values, 95% confidence intervals [CI] and also likelihood ratios (LR) were calculated.

Results: Node histology demonstrated tumor involvement in 546 out of 2987 lymph nodes. Sestamibi was positive in 30 axillas (25 true-positive) and negative in 120 (only 55 true-negative). The sensitivity corresponded to 27.8% [CI = 18.9-38.2] and specificity to 91.7% [81.6-97.2]. The positive and negative LR were 3.33 and 0.79, respectively. There was no difference between early and delayed images. Sensitivity was higher in patients with palpable lesions.

Conclusion: This work confirmed that non tomographic Tc99m sestamibi scintimammography had a very low detection rate for axillary lymph node involvement and it should not be applied for clinical assessment of breast cancer.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一项国际多中心试验的结果表明,在乳腺癌方案的腋窝评估中,应谨慎考虑平面Tc99m- sestamibi扫描造影术。
背景:淋巴结状态是乳腺癌新近诊断的原发病变中最重要的预后指标。作为使用Tc99m化合物的区域间扫描成像方案的一部分,提出了平面Tc99m sestamibi扫描对腋窝淋巴结评估的价值。由于有广泛的报道值,一个标准化的平面成像方案被执行。方法:前瞻性纳入来自不同地区的女性患者149例。平均年龄55.1±11.9岁。150例腋窝切除淋巴结2987例,获得组织学报告。所有患者均在10分钟获得早期平面胸部图像,95例患者延迟获得平面胸部图像,所有图像均使用740-925 MBq剂量的Tc99m sestamibi进行。所有腋窝区域的盲讲课由2名独立观察员解释,认为任何明确的摄取增加的病灶区域都是受累的腋窝。计算诊断值、95%置信区间[CI]和似然比(LR)。结果:2987个淋巴结中546个有肿瘤累及。Sestamibi阳性30例(25例真阳性),阴性120例(只有55例真阴性)。敏感性为27.8% [CI = 18.9-38.2],特异性为91.7%[81.6-97.2]。正、负LR分别为3.33和0.79。早期和延迟图像之间没有差异。可触及病变的患者敏感性更高。结论:本工作证实了非层析Tc99m sstamibi膜层摄影对腋窝淋巴结受累的检出率极低,不宜用于乳腺癌的临床评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computer-assisted lateralization of unilateral temporal lobe epilepsy using Z-score parametric F-18 FDG PET images. Comparison of 2D, 3D high dose and 3D low dose gated myocardial 82Rb PET imaging. Toxicology evaluation of radiotracer doses of 3'-deoxy-3'-[18F]fluorothymidine (18F-FLT) for human PET imaging: Laboratory analysis of serial blood samples and comparison to previously investigated therapeutic FLT doses. Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1